KROHNE OPTIFLUX 1100 Wafer-style Electromagnetic Flowmeter with HART
1. Product Overview
The Krohne OPTIFLUX 1100 is a wafer-style electromagnetic flowmeter from the OPTIFLUX 1000 economy platform, specified for small-bore installations that need HART communication as a standard option.
The sensor covers DN10 to DN150 with PFA or rubber liner and a minimum conductivity of 5 uS/cm. Process temperature reaches up to +130 degC and the pressure range is PN16 to PN40. The available output is 4-20 mA with HART communication.
This page is a selection overview. The HART converter configuration, liner selection and the complete ordering code are per the official data sheet; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Platform: OPTIFLUX 1000 economy wafer platform.
Nominal size: DN10 to DN150 in wafer execution.
Liner and conductivity: PFA or rubber liner; conductivity at least 5 uS/cm.
Process conditions: Up to +130 degC and PN16 to PN40.
Output: 4-20 mA with HART communication as a standard option.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Wafer electromagnetic flowmeter with HART |
| Series / model | KROHNE OPTIFLUX 1100 |
| Platform | OPTIFLUX 1000 economy wafer platform |
| Nominal size | DN10 to DN150, wafer |
| Measuring principle | Faraday electromagnetic induction |
| Liner | PFA or rubber |
| Minimum conductivity | at least 5 uS/cm |
| Process temperature | up to +130 degC |
| Process pressure | PN16 to PN40 |
| Output / communication | 4-20 mA with HART |
| Signal converter | IFC series converter |
| Typical application | Small-bore wafer metering needing HART communication |
| Ordering code | Ordering code per official data sheet; verify with the manufacturer |
| Dimensions / weight | See the official data sheet for dimensions, mounting interface and weight |
4. Selection Guide
Selection sequence: Medium check -> Size check -> Liner check -> Process check -> Communication check -> Ordering check.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm a conductive liquid at or above 5 uS/cm |
| 2 | Size check | Confirm a DN10 to DN150 wafer installation |
| 3 | Liner check | Choose PFA or rubber liner for the medium |
| 4 | Process check | Confirm up to +130 degC and PN16 to PN40 |
| 5 | Communication check | Confirm that the 4-20 mA with HART option fits the control system |
| 6 | Ordering check | Verify the sensor and converter codes; Ordering code per official data sheet; verify with the manufacturer |
Boundary: The HART option is standard on this model. Liner, flange and converter details still follow the official data sheet; Ordering code per official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model / configuration | Function | Description |
|---|---|---|
| OPTIFLUX 1100 compact | Wafer flowmeter | Sensor with directly mounted IFC converter |
| OPTIFLUX 1100 remote | Wafer flowmeter | Sensor with remote IFC converter |
| OPTIFLUX 1100 PFA | Corrosion version | PFA liner for small-bore chemical service |
| OPTIFLUX 1100 rubber | General version | Rubber liner for general industrial service |
| OPTIFLUX 1100 HART | Communication option | 4-20 mA with HART as standard option |
| Other configurations | Per official data sheet | Ordering code per official data sheet; verify with the manufacturer |
6. Related Models
| Related model | Description |
|---|---|
| OPTIFLUX 1050 | Economy wafer flowmeter with optional HART |
| OPTIFLUX 1300 | Wafer flowmeter for chemical service |
| OPTIFLUX 1400 | Wafer flowmeter with multiphase option |
| OPTIFLUX 2400 | Full-bore water and process flowmeter |
| OPTIFLUX 4400 | Chemical platform flowmeter for higher temperature |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrodes | Matched to the original wafer sensor |
| PFA or rubber liner | Matched to the original nominal size |
| IFC converter module | Matched to the original HART configuration |
| Wafer gasket set | Selected to the nominal size and liner |
| Grounding ring | Matched to the original pipe and liner |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Selected for 4-20 mA with HART |
| HART communication tool | For device configuration and diagnostics |
| Flange gasket set | Selected to the wafer nominal size |
| Grounding ring | For reliable pipe bonding on lined lines |
| Remote mounting kit | Where the converter is mounted away from the sensor |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH