Home » Products » KROHNE
KROHNE OPTIFLUX 1100 Wafer-style Electromagnetic Flowmeter with HART
KROHNE OPTIFLUX 1100 Wafer-style Electromagnetic Flowmeter with HART
KROHNE OPTIFLUX 1100 Wafer-style Electromagnetic Flowmeter with HART

KROHNE OPTIFLUX 1100 Wafer-style Electromagnetic Flowmeter with HART

Details

1. Product Overview

The Krohne OPTIFLUX 1100 is a wafer-style electromagnetic flowmeter from the OPTIFLUX 1000 economy platform, specified for small-bore installations that need HART communication as a standard option.

The sensor covers DN10 to DN150 with PFA or rubber liner and a minimum conductivity of 5 uS/cm. Process temperature reaches up to +130 degC and the pressure range is PN16 to PN40. The available output is 4-20 mA with HART communication.

This page is a selection overview. The HART converter configuration, liner selection and the complete ordering code are per the official data sheet; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Platform: OPTIFLUX 1000 economy wafer platform.

Nominal size: DN10 to DN150 in wafer execution.

Liner and conductivity: PFA or rubber liner; conductivity at least 5 uS/cm.

Process conditions: Up to +130 degC and PN16 to PN40.

Output: 4-20 mA with HART communication as a standard option.

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeWafer electromagnetic flowmeter with HART
Series / modelKROHNE OPTIFLUX 1100
PlatformOPTIFLUX 1000 economy wafer platform
Nominal sizeDN10 to DN150, wafer
Measuring principleFaraday electromagnetic induction
LinerPFA or rubber
Minimum conductivityat least 5 uS/cm
Process temperatureup to +130 degC
Process pressurePN16 to PN40
Output / communication4-20 mA with HART
Signal converterIFC series converter
Typical applicationSmall-bore wafer metering needing HART communication
Ordering codeOrdering code per official data sheet; verify with the manufacturer
Dimensions / weightSee the official data sheet for dimensions, mounting interface and weight
Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Size check -> Liner check -> Process check -> Communication check -> Ordering check.

StepItemKey point
1Medium checkConfirm a conductive liquid at or above 5 uS/cm
2Size checkConfirm a DN10 to DN150 wafer installation
3Liner checkChoose PFA or rubber liner for the medium
4Process checkConfirm up to +130 degC and PN16 to PN40
5Communication checkConfirm that the 4-20 mA with HART option fits the control system
6Ordering checkVerify the sensor and converter codes; Ordering code per official data sheet; verify with the manufacturer

Boundary: The HART option is standard on this model. Liner, flange and converter details still follow the official data sheet; Ordering code per official data sheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model / configurationFunctionDescription
OPTIFLUX 1100 compactWafer flowmeterSensor with directly mounted IFC converter
OPTIFLUX 1100 remoteWafer flowmeterSensor with remote IFC converter
OPTIFLUX 1100 PFACorrosion versionPFA liner for small-bore chemical service
OPTIFLUX 1100 rubberGeneral versionRubber liner for general industrial service
OPTIFLUX 1100 HARTCommunication option4-20 mA with HART as standard option
Other configurationsPer official data sheetOrdering code per official data sheet; verify with the manufacturer

6. Related Models

Related modelDescription
OPTIFLUX 1050Economy wafer flowmeter with optional HART
OPTIFLUX 1300Wafer flowmeter for chemical service
OPTIFLUX 1400Wafer flowmeter with multiphase option
OPTIFLUX 2400Full-bore water and process flowmeter
OPTIFLUX 4400Chemical platform flowmeter for higher temperature

7. Common Spare Parts

Spare partDescription
Measuring electrodesMatched to the original wafer sensor
PFA or rubber linerMatched to the original nominal size
IFC converter moduleMatched to the original HART configuration
Wafer gasket setSelected to the nominal size and liner
Grounding ringMatched to the original pipe and liner

8. Accessories

AccessoryDescription
IFC signal converterSelected for 4-20 mA with HART
HART communication toolFor device configuration and diagnostics
Flange gasket setSelected to the wafer nominal size
Grounding ringFor reliable pipe bonding on lined lines
Remote mounting kitWhere the converter is mounted away from the sensor

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area