SAMSON 2469/2430 Flow Temperature Regulator (DN15-DN50)
1. Product Overview
The SAMSON 2469/2430 is a self-operated flow temperature regulator for DN15 to DN50 at PN16 to PN25. It combines temperature sensing with flow regulation and keeps the controlled temperature at the set point without an external energy supply.
The regulator is driven by the temperature of the regulated medium, which acts through a sensor and the operating element on the valve. It belongs to the temperature branch of the self-operated regulator programme and is used in heating and cooling water systems.
This catalogue section is a selection overview. Set point ranges, flow data, materials and the digit-by-digit ordering code are per the official data sheet and the nameplate; Per official data sheet, verify with manufacturer. The ordering code is to be supplemented / generated by selection software.



2. Technical Description
Operating principle: Self-operated proportional temperature regulation with flow control; the sensor drives the valve without auxiliary power.
Size and pressure: DN15-DN50, PN16-PN25.
Drive energy: Temperature of the regulated medium (no external power supply).
Medium: Heating and cooling water.
Body material: Per official data sheet, verify with manufacturer.
Ordering boundary: Official data sheet for the self-operated temperature regulators; the digit-by-digit ordering code is to be supplemented / generated by selection software; Ordering code per official data sheet / selection software, verify with manufacturer.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Self-operated flow temperature regulator |
| Series / model | SAMSON 2469 / 2430 |
| Design | Self-operated temperature regulator with flow control |
| Nominal size | DN15-DN50 |
| Pressure rating | PN16-PN25 |
| Operating principle | Self-operated, proportional control |
| Drive energy | Temperature of the regulated medium (no external power supply) |
| Control variable | Temperature with integrated flow regulation |
| Set point range | Per official data sheet, verify with manufacturer |
| Medium | Heating and cooling water |
| Connection form | Per official data sheet, verify with manufacturer |
| Body material | Per official data sheet, verify with manufacturer |
| Technical data sheet | Per official temperature regulator data sheet, verify with manufacturer |
| Ordering code | Ordering code per official data sheet / selection software, verify with manufacturer |
4. Selection Guide
Selection sequence: Duty confirmation -> Size and pressure -> Set point and flow data -> Installation -> Ordering check.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty confirmation | Confirm the controlled temperature and the flow requirement |
| 2 | Size and pressure | Select within DN15-DN50 and PN16-PN25 |
| 3 | Set point and flow data | Check set point range and flow data against the official data sheet |
| 4 | Installation | Confirm the sensor installation position and the connection form |
| 5 | Ordering check | Ordering code to be supplemented / generated by selection software; Ordering code per official data sheet / selection software, verify with manufacturer |
Boundary: Set point range, flow data and materials must be checked against the official data sheet and nameplate; Per official data sheet, verify with manufacturer. The digit-by-digit ordering code is to be supplemented / generated by selection software; Ordering code per official data sheet / selection software, verify with manufacturer.
5. Complete Model Enumeration
| Model / configuration | Function | Description |
|---|---|---|
| 2469 | Flow temperature regulator | DN15-DN50, PN16-PN25; temperature control with flow regulation |
| 2430 | Flow temperature regulator | Companion model of the same temperature control family |
| Type 1 | Temperature regulator with sensor | DN15-DN50, PN16-PN40; self-operated temperature control |
| 43-5 | Compact temperature regulator | PN25, G1/2-G1; another temperature regulator option |
| Other ordering configurations | Per official data sheet | Complete ordering code per official data sheet; verify with the manufacturer |
6. Related Models
| Related model | Description |
|---|---|
| Type 1 | Self-operated temperature regulator with sensor, DN15-DN50 |
| Type 4 | Self-operated temperature regulator, Class 125, NPS 1/2-6 |
| 43-5 | Compact temperature regulator, PN25, G1/2-G1 |
| 2489 | Compact flow control valve with electric actuator and thermostat |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Temperature sensor | Matched to the original set point range; refer to the official spare parts list |
| Operating element | Checked to the original regulator; refer to the official spare parts list |
| Seat and plug | Checked to the original nominal size; refer to the official spare parts list |
| Packing set | Selected for the original medium; refer to the official spare parts list |
| Flow control element | Checked to the original configuration; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Sensor well / thermowell | For sensor installation in the pipeline; matched per official data sheet |
| Flange connection parts | Selected to the piping flange standard |
| Isolation valves | Installed for maintenance and removal of the regulator |
| Thermometer | For local temperature indication |
| Strainer | Installed upstream to protect the seat and flow control element |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH
