SAMSON 3730 Explosion-Proof Versions (Ex ia / Ex d) - Wiring & Installation
Release time:2026-11-25 12:00:52 | Views:

The SAMSON 3730 family is mainly intrinsically safe (Ex ia); the 3731 family is the version designed for flameproof Ex d enclosures, and the 3730-6 has dedicated Ex d[ja]/Ex db[ja] options (order codes 210/211). Ex ia intrinsic safety is NOT Ex d flameproof: the energy-limiting principle, wiring and barrier requirements, and enclosure construction are completely different and must never be mixed. This article covers explosion protection types, IS loop wiring, flameproof installation and certification codes based on official data sheets and the IECEx certificate; unverified approvals are stated as "unable to confirm, please verify with the manufacturer".

I. Product Positioning

ItemContent
BrandSAMSON (independent brand)
IS platform3730-0/1/2/3/4/5 (mainly Ex ia, plus Ex nA non-sparking and dust protection; no Ex d)
Flameproof platform3731-3 (HART) and 3731-5 (FF), with Ex d cast-aluminium or stainless-steel enclosure and 15-digit article code
Special design3730-6 (pressure monitoring, 14-digit code with Ex d[ja] options 210/211), 3730-6 TS (SIL)
Core differenceEx ia limits electrical energy below ignition level; Ex d contains an internal explosion and prevents flame propagation
Main documentsT 8384-3/4/5 EN, T 8384-6 EN, T 8387-3/5 EN, NA 0122, IECEx PT B 05.0008X

Source: SAMSON official data sheets T 8384-3/4/5/6 EN, T 8387-3/5 EN and IECEx certificate IECEx PT B 05.0008X; actual approval markings subject to the nameplate and certificate.

SAMSON 3730 series positioner illustration
SAMSON 3730 series positioner illustration, same-series reference; parameters subject to the official data sheet

II. Ex ia versus Ex d

ItemEx ia intrinsic safetyEx d flameproof
Protection principleLimits voltage, current, capacitance and inductance below ignition levelEnclosure withstands internal explosion and stops flame through flameproof joints
AreaSuitable for Zone 0 / Div.1 with a safety barrierTypically Zone 1 / Div.1 with a flameproof enclosure and terminal box
WiringIS loop requires a safety barrier / isolator with controlled cable constantsCable glands must be flameproof; terminal compartment separate and intact
EnclosureStandard aluminium or stainless housing with IS approvalCast-aluminium or stainless flameproof housing; 3731 has a separate Ex d terminal compartment
Typical models3730-3 (P1=1 ATEX Ex ia, P1=3 CSA, P1=5 FM)3731-3 / 3731-5; options 210/211 on the 3730-6

Source: SAMSON official data sheets T 8384-3 EN, T 8387-3/5 EN and T 8384-6 EN; approval names and temperature classes subject to nameplate and certificate.

III. Intrinsically Safe (Ex ia) Loop Wiring

ItemRequirement / parameter
Input signal4-20 mA two-wire, reverse polarity protection; 3.6 mA minimum for display, 3.8 mA for operation
Load impedanceUp to 8.2 V (equivalent to 410 ohm at 20 mA); HART frequency range receiving 350-450 ohm, sending about 115 ohm
Safety barrierIS loop must use a safety barrier or isolator per approval parameters, with cable capacitance and inductance checked
Switching outputsFault alarm output, software limit switches and inductive limit switch on Ex versions must be analysed by a NAMUR switching amplifier (EN 50227 / EN 60947-5-6)
Electrical connectionOne M20x1.5 cable gland (6-12 mm clamping range), second M20x1.5 connection optional; screw terminals for 0.2-2.5 mm2 wire
Signal stateNon-Ex: non-conductive / conductive (about 348 ohm); Ex: up to 1.0 mA / at least 2.2 mA

Source: SAMSON official data sheet T 8384-3 EN Technical data and Binary contacts table, and the 3730-3 operating instructions; IS loop calculation subject to the approval documents.

IV. Flameproof (Ex d) Installation

ItemRequirement / parameter
EnclosureAll parts enclosed in an Ex d housing; electrical connection through a separate Ex d terminal compartment
3731-3 article code15 digits; digit 1 = 3 (HART), digits 2-3 = 21 ATEX Ex db IIC T6 Gb / 23 FM / 24 EAC / 27 JIS
3731-5 article code15 digits; digit 1 = 5 (FF), digits 2-4 = 210 ATEX Ex db IIC T6 Gb / 230 CSA-FM / 270 JIS
Cable entry1 = 2x M20x1.5; 2 = 2x 1/2 NPT; flameproof joints and seals must remain intact
DiagnosticsIntegrated EXPERTplus including partial stroke test; optional binary output (NAMUR/PLC)
MountingDirect to Type 3277-5 / 3277 actuators, IEC 60534-6-1 (NAMUR) bracket or VDI/VDE 3845 rotary actuators; any position but not suspended

Source: SAMSON official data sheets T 8387-3/5 EN and the 3731-3 English operating manual, Design and principle of operation; wiring must be performed by qualified personnel per the certificate.

V. Approval Codes and Ordering Digits

ModelApproval fieldCodeMarking / approval
3730-3P1 (1 digit)0No explosion protection
3730-3P11ATEX II 2G Ex ia IIC Gb; II 2D Ex ia IIIC T80 C Db
3730-3P13CSA Ex ia IIC T6; Class I, Zone 0
3730-3P15FM AEx ia IIC; Class I, Zone 0
3730-3P18ATEX II 2D Ex tb IIIC T80 C Db (dust)
3730-6P1-P3 (3 digits)110 / 111 / 112ATEX / IECEx / CCC-NEPSI Ex ia
3730-6P1-P3210 / 211ATEX / IECEx Ex d[ja] / Ex db[ja] (dedicated flameproof option)

For 3730-4 (PROFIBUS PA) and 3730-5 (FF), digit 4 is mandatorily 0 as the bus identifier; for 3730-5 the explosion protection occupies four digits P1 and P14-P16. The 15-digit 3731 article code has a different structure from the 16-digit 3730 code and the tables must not be interchanged.

Source: SAMSON official data sheets T 8384-3/4/5/6 EN and T 8387-3/5 EN article code tables; complete codes subject to the official selection tool.

VI. Selection Guide and Common Models

Selection guide:Set the protection type from the area classification first: for a Zone 0 IS loop choose the Ex ia code on the 3730-3 with a safety barrier; where a flameproof enclosure is explicitly required choose the 3731-3 (HART) or 3731-5 (FF); consider the 3730-6 options 210/211 only when pressure monitoring is needed and Ex d[ja] is acceptable. Ex ia intrinsic safety is NOT Ex d flameproof and must never be mixed; if an approval (ATEX/IECEx/CCC/NEPSI) cannot be verified, state "unable to confirm, please verify with the manufacturer" and do not imply that only one model holds an approval. Flameproof wiring must be done by qualified personnel with seal checks per the certificate.

Common models:3730-3 (HART, mainly IS), 3730-4 (PROFIBUS PA), 3730-5 (FF), 3730-6 (pressure monitoring, 14 digits), 3731-3 (HART flameproof), 3731-5 (FF flameproof). Approval fields and article codes subject to the SAMSON data sheets and selection tool.

If you are confirming the explosion protection type and wiring for a positioner in a hazardous area, or are unsure whether a unit is Ex ia or Ex d, please send us the area classification, approval requirements and ordering code. We can check the approval digits and wiring requirements against the official data sheets.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.