Home » Service & Support » Technical Documentation
Fisher 657 / 667 Spring-and-Diaphragm Actuators - Technical Data & Selection
Release time:2026-11-25 09:02:26 | Views:

Fisher 657 and 667 are spring-opposed diaphragm, linear actuators from Fisher (an Emerson brand), used for on/off or throttling service on sliding-stem valves such as globes, angles and desuperheaters. The 657 is direct-acting and the 667 reverse-acting; both share the same size range and integrate with FIELDVUE digital valve controllers. This article summarizes technical data, variants and selection points from the official product bulletin and website.

I. Product Positioning

ItemContent
Brand ownershipFisher is an Emerson brand
Series657 / 667 spring-opposed diaphragm, linear actuators
Action657 direct-acting; 667 reverse-acting
Typical serviceOn/off or throttling on sliding-stem valves (easy-e globes, angles, desuperheaters)
Main approvalsSIL capable, ATEX, CUTR, PED (official website specification)
Main documentProduct Bulletin 61.1:657 / 667, document D100087X012

The data in this article was obtained via web search. Source: Emerson official Fisher 657 product page https://emerson.com/zh/final-control/products/fisher-657 ; Fisher Product Bulletin D100087X012.

Fisher product illustration
Pneumatic actuator illustration, not a 657/667 unit; parameters subject to the official data sheet

II. Action Differences: 657 vs 667

Item657667
ActionDirect-actingReverse-acting
Pressure inletUpper diaphragm casing; stem moves downLower diaphragm casing; stem moves up against spring
Position on air failureSpring drives stem to full upper positionSpring drives stem to full lower position
Failure action with push-down-to-closeFail-open (verify against valve type)Fail-closed (verify against valve type)
Size range30/34/40/45/46/50/60/70/80/87/100Same range as 657, plus size 76
MountingIntegral mounting pad, internal air passage, FIELDVUE-readySame integral pad; external tubing possible

Source: Fisher Product Bulletin D100087X012 and the official website; the actual fail action must be confirmed together with PDTO/PDTC valve action.

III. Core Technical Data

ParameterOfficial basis
Effective diaphragm area297-2902 cm2 (46-450 in2), by size
Maximum allowable thrust10,231 N (size 30/34) to 200,160 N (size 100)
Maximum travel19-102 mm, by size (102 mm for size 100)
Supply pressure (standard range)0.2-1.0 bar (3-15 psig) or 0.4-2.0 bar (6-30 psig)
Operating temperatureStandard nitrile -40 to 82 C; optional silicone -54 to 149 C; low-temperature to -50 C
Weight (without handwheel)Approx. 16-544 kg, by size
Signal connection1/4-1 NPT, by size

Source: Fisher Product Bulletin D100087X012 (61.1:657). Final values subject to the size-specific manual and nameplate.

IV. Common Variants

VariantFeatureSelection note
657 / 667 baseSpring-opposed diaphragm, direct / reverse actingGeneral on/off and throttling on sliding-stem valves
657NS / 667NSNo-spring version; fail position set by loadSizes 40/45/70/80; verify stem unbalanced force
657NS2 / 667NS2No-spring plus nuclear-service seismic constructionSizes 45/70/80; follow nuclear project specifications
C / R / -4 variantsDerivative codes listed in the bulletinDigit definitions subject to official ordering codes; not guessed here

Source: Fisher Product Bulletin D100087X012 and official product variants; undocumented codes subject to the official ordering tool/manual.

V. Selection and Installation Points

StepPoint
1 ActionChoose 657 (direct) or 667 (reverse) for the required fail-safe action; check PDTO/PDTC
2 ThrustCheck stem unbalanced force, packing friction and spring range against maximum allowable thrust
3 Size and travelSelect size by required thrust and travel; do not exceed the size limit
4 Spring rangeSpring rate and number determine span; set bench per the official manual
5 PositionerIntegral pad and air passage accept FIELDVUE directly; traditional bracket kits remain compatible
6 AccessoriesAdd travel stops, handwheel or limit switches as needed; verify temperature and approvals

Source: Fisher Product Bulletin D100087X012 and official product description; installation details subject to the size-specific instruction manual.

VI. Selection Guide and Common Models

Selection guide: Select 657/667 in the order action and fail position first, then thrust and travel, then size, accessories and approvals. The two share a size range but act in opposite directions and are not interchangeable. NS/NS2 are no-spring versions whose fail position depends on load, so stem unbalanced force must be checked. All data above is from the official bulletin and website, subject to the official manual and nameplate.

Common models: 657 (direct-acting) and 667 (reverse-acting) base sizes 30 through 100; 657NS/667NS (no-spring) and 657NS2/667NS2 (nuclear service). Final ordering codes subject to the Emerson official selection tool and order confirmation.

If you are selecting a spring-and-diaphragm actuator for a sliding-stem valve, or need to distinguish the action, thrust and size of the 657 and 667, please send us the valve type, fail-safe requirement and air supply conditions. We can review the model and parameters item by item against the official bulletin.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.