Fisher Type C891 Internal Valve
The Fisher FIELDVUE DVC6200 instrument allows for your operation to run closer to setpoint, improving product quality with more accurate control. Using FIELDVUE Performance Diagnostics, valve operation is monitored online to evaluate performance and reliability.
1. Product Overview
The Fisher Type C891 is an internal valve used for primary shutoff on LP-Gas and anhydrous ammonia storage and transfer systems. It belongs to the C series of internal valves that also includes C404-32, C486, C471/C477, C483/C484 and C804H-32.
The valve is installed at the tank opening and closes on excess flow, remote signal or thermal release. It is built with a stainless steel body and trim, with PTFE packing and NBR disc and O-rings as standard.
Fisher does not publish Cv or Cg values for the C891; capacity is described by the closing flow at a stated differential, and the official bulletin gives closing flow tables for 2 in and 3 in bodies.



2. Technical Description
Primary shutoff: Mounted inside the tank opening as the primary shutdown device for transfer service.
Excess-flow closing: Closes when flow exceeds the selected closing flow setting.
Stainless construction: Body, gland, disc holder, springs and shafts are stainless steel.
PTFE and NBR: PTFE gland packing, liner bushing and wear plug; NBR disc and O-rings standard.
Flanged ends: 2 or 3 in CL300 RF flanged inlet and outlet, with side and straight-through outlets.
Capacity basis: Expressed as closing flow in GPM rather than Cv or Cg.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Valve type | Internal valve (primary tank shutoff valve) |
| Series | C series internal valves including C891 |
| Body sizes | 2 in / DN 50 and 3 in / DN 80 |
| End connections | 2 or 3 in CL300 RF flanged; two outlets, side and straight-through |
| Maximum inlet pressure | 500 psig / 34.5 bar WOG for the C891 series; C897 threaded series 400 psig / 27.6 bar |
| Closing flow - 2 in | Bottom filling 105 / 150 / 250 GPM; top filling 120 / 170 / 250 GPM |
| Closing flow - 3 in | Bottom filling 160 / 265 / 375 / 460 GPM; top filling 180 / 290 / 395 / 460 GPM |
| Closing flow springs - 2 in | 105, 150 and 250 GPM / 397, 568 and 946 L/min |
| Closing flow springs - 3 in | 160, 265, 375 and 460 GPM / 605, 1003, 1419 and 1741 L/min |
| Body material | Stainless steel; the S in the model indicates a stainless steel gland |
| Trim material | Stainless steel body, gland, disc holder and springs; PTFE packing and liner bushing |
| Elastomers | NBR disc and O-rings standard; PTFE, CR, FKM, EPDM, FFKM and low-temperature NBR optional |
| Temperature capability | -20 to 150 F / -29 to 66 C; tested down to -40 F / -40 C without leakage |
| Cv / Cg | Not published by Fisher; capacity is characterized by the excess-flow closing flow |
4. Selection Guide
Selection sequence: Service -> Size -> Closing flow -> Elastomer -> Connection.
| Step | Item | Key point |
|---|---|---|
| 1 | Service | Confirm LP-Gas or anhydrous ammonia primary shutoff duty |
| 2 | Size | Choose the 2 in or 3 in body from the required closing flow |
| 3 | Closing flow | Select the excess-flow spring from the bottom or top filling table |
| 4 | Elastomer | Choose NBR or one of the optional elastomers by media and temperature |
| 5 | Connection | Confirm the CL300 RF flange arrangement and side / straight outlet orientation |
Boundary: Closing flow tables, pressure ratings and materials follow the official bulletin and manual; Cv and Cg are not published for this series.
5. Complete Model Enumeration
| Model | Size | Description |
|---|---|---|
| C891 2 in | DN 50 | Internal valve with 105/150/250 GPM closing flow springs |
| C891 3 in | DN 80 | Internal valve with 160/265/375/460 GPM closing flow springs |
| C404-32 / C486 | Other C series | Internal valves in the same Fisher C series |
| C471 / C477 / C483 / C804H-32 | Other C series | Related internal valve models |
6. Related Models
| Related model | Description |
|---|---|
| C404-32 | Internal valve in the Fisher C series |
| C486 | Internal valve in the Fisher C series |
| C804H-32 | Internal valve in the Fisher C series |
| Type N551 | In-line emergency shutoff valve |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Disc and O-ring kit | NBR standard with optional PTFE, CR, FKM, EPDM or FFKM |
| Closing flow spring | Spring by 2 in or 3 in closing flow rating |
| Gland packing set | PTFE packing and liner bushing |
| Actuator linkage | Operating shaft and linkage components |
8. Accessories
| Accessory | Description |
|---|---|
| Remote release | Cable or pneumatic release mechanism |
| Excess-flow actuator | Actuation package matched to the closing flow spring |
| Hose coupling | Transfer hose connection at the outlet |
| Vent valve | Connection for tank depressuring |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China