The Fisher Type C891 is an internal valve used for primary shutoff on LP-Gas and anhydrous ammonia storage and transfer systems. It belongs to the C series of internal valves that also includes C404-32, C486, C471/C477, C483/C484 and C804H-32.

The valve is installed at the tank opening and closes on excess flow, remote signal or thermal release. It is built with a stainless steel body and trim, with PTFE packing and NBR disc and O-rings as standard.

Fisher does not publish Cv or Cg values for the C891; capacity is described by the closing flow at a stated differential, and the official bulletin gives closing flow tables for 2 in and 3 in bodies.

Above: product appearance / manufacturer literature image.

2. Technical Description

Primary shutoff: Mounted inside the tank opening as the primary shutdown device for transfer service.

Excess-flow closing: Closes when flow exceeds the selected closing flow setting.

Stainless construction: Body, gland, disc holder, springs and shafts are stainless steel.

PTFE and NBR: PTFE gland packing, liner bushing and wear plug; NBR disc and O-rings standard.

Flanged ends: 2 or 3 in CL300 RF flanged inlet and outlet, with side and straight-through outlets.

Capacity basis: Expressed as closing flow in GPM rather than Cv or Cg.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 04 - Internal Valves; official Type C891 Internal Valve Instruction Manual MCK-2289 and Bulletin D450246T012.

3. Main Technical Specifications

ParameterSpecification / Description
Valve typeInternal valve (primary tank shutoff valve)
SeriesC series internal valves including C891
Body sizes2 in / DN 50 and 3 in / DN 80
End connections2 or 3 in CL300 RF flanged; two outlets, side and straight-through
Maximum inlet pressure500 psig / 34.5 bar WOG for the C891 series; C897 threaded series 400 psig / 27.6 bar
Closing flow - 2 inBottom filling 105 / 150 / 250 GPM; top filling 120 / 170 / 250 GPM
Closing flow - 3 inBottom filling 160 / 265 / 375 / 460 GPM; top filling 180 / 290 / 395 / 460 GPM
Closing flow springs - 2 in105, 150 and 250 GPM / 397, 568 and 946 L/min
Closing flow springs - 3 in160, 265, 375 and 460 GPM / 605, 1003, 1419 and 1741 L/min
Body materialStainless steel; the S in the model indicates a stainless steel gland
Trim materialStainless steel body, gland, disc holder and springs; PTFE packing and liner bushing
ElastomersNBR disc and O-rings standard; PTFE, CR, FKM, EPDM, FFKM and low-temperature NBR optional
Temperature capability-20 to 150 F / -29 to 66 C; tested down to -40 F / -40 C without leakage
Cv / CgNot published by Fisher; capacity is characterized by the excess-flow closing flow
Source: Fisher Pressure Regulator Technical Data Supplement, Volume 04 - Internal Valves; official Type C891 Internal Valve Instruction Manual MCK-2289 and Bulletin D450246T012.

4. Selection Guide

Selection sequence: Service -> Size -> Closing flow -> Elastomer -> Connection.

StepItemKey point
1ServiceConfirm LP-Gas or anhydrous ammonia primary shutoff duty
2SizeChoose the 2 in or 3 in body from the required closing flow
3Closing flowSelect the excess-flow spring from the bottom or top filling table
4ElastomerChoose NBR or one of the optional elastomers by media and temperature
5ConnectionConfirm the CL300 RF flange arrangement and side / straight outlet orientation

Boundary: Closing flow tables, pressure ratings and materials follow the official bulletin and manual; Cv and Cg are not published for this series.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 04 - Internal Valves; official Type C891 Internal Valve Instruction Manual MCK-2289 and Bulletin D450246T012.

5. Complete Model Enumeration

ModelSizeDescription
C891 2 inDN 50Internal valve with 105/150/250 GPM closing flow springs
C891 3 inDN 80Internal valve with 160/265/375/460 GPM closing flow springs
C404-32 / C486Other C seriesInternal valves in the same Fisher C series
C471 / C477 / C483 / C804H-32Other C seriesRelated internal valve models

6. Related Models

Related modelDescription
C404-32Internal valve in the Fisher C series
C486Internal valve in the Fisher C series
C804H-32Internal valve in the Fisher C series
Type N551In-line emergency shutoff valve

7. Common Spare Parts

Spare partDescription
Disc and O-ring kitNBR standard with optional PTFE, CR, FKM, EPDM or FFKM
Closing flow springSpring by 2 in or 3 in closing flow rating
Gland packing setPTFE packing and liner bushing
Actuator linkageOperating shaft and linkage components

8. Accessories

AccessoryDescription
Remote releaseCable or pneumatic release mechanism
Excess-flow actuatorActuation package matched to the closing flow spring
Hose couplingTransfer hose connection at the outlet
Vent valveConnection for tank depressuring

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 04 - Internal Valves; official Type C891 Internal Valve Instruction Manual MCK-2289 and Bulletin D450246T012.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area

Energy

Energy

Chemical Industry

Chemical Industry

Mining Industry

Mining Industry

Pharmaceutical Industry

Pharmaceutical Industry

Water treatment industry

Water treatment industry