Home » Products » Fisher
Fisher G200 and G201 Back Check Valves
Fisher G200 and G201 Back Check Valves
Fisher G200 and G201 Back Check Valves

Fisher G200 and G201 Back Check Valves

The Fisher FIELDVUE DVC6200 instrument allows for your operation to run closer to setpoint, improving product quality with more accurate control. Using FIELDVUE Performance Diagnostics, valve operation is monitored online to evaluate performance and reliability.

Details

1. Product Overview

The Fisher G200 and G201 series back check valves are designed for heavy-duty in-line service in the transfer area of bulk plants, for LP-Gas or anhydrous ammonia.

As differential pressure develops, the spring-loaded poppet opens immediately; when flow stops or reverses, the valve closes. The soft seat provides tight shutoff so that the line can be depressured for maintenance without leakage.

The G201 is identical to the G200 but includes an integral flow indicator, which can replace a sight flow indicator in the transfer line.

Above: product appearance / manufacturer literature image.

2. Technical Description

Heavy duty: Designed for bulk plant transfer area piping.

G201 indicator: Includes an integral flow indicator; the G200 does not.

Soft seat: Tight shutoff permits blowdown maintenance without leakage.

Materials: 303 stainless steel poppet, stem and pipe plug; aluminum gasket, indicator and spacer; nylon PA sliding disc; 302 stainless spring.

Size range: 1-1/4, 2 and 3 in FNPT inlet and outlet.

Flow data: Propane capacity published at 10 psig differential; no Cv or Cg values are given by Fisher.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 13 - Check Valves; official G200 Series Back Check Valves Instruction Manual MCK-1146, Types G200 and G201 Replacement Parts Sheet VCIMD-11413-EN, and Bulletin LP-37.

3. Main Technical Specifications

ParameterSpecification / Description
Valve typeHeavy-duty back check valve; G201 adds a flow indicator
G200-10 / G201-101-1/4 in FNPT inlet and outlet
G200-16 / G201-162 in FNPT inlet and outlet
G200-24 / G201-243 in FNPT inlet and outlet
Maximum inlet pressure400 psi / 27.6 bar WOG
Temperature capability-40 to 160 F / -40 to 71 C
Flow at 10 psig differential (propane)G200-10/G201-10 about 190 GPM / 719 L/min; G200-16 about 350 GPM / 1325 L/min; G200-24 about 800 GPM / 3028 L/min
Internal materials303 stainless steel poppet, stem and pipe plug; nylon PA sliding disc; 302 stainless spring
Other materialsAluminum gasket, indicator and spacer; ductile iron body per product page
SeatSoft seat for tight shutoff
Flow directionInstall with the flow in the direction of the nameplate arrow, entering from the flange end
Assembly torque40 to 50 ft-lb / 54 to 68 N-m for size 24; 25 to 35 ft-lb / 34 to 47 N-m for sizes 10 and 16
Cv / CgNot published by Fisher; capacity is expressed as flow at 10 psig differential
CertificationsNo separate UL or ATEX statement located; installation follows NFPA No. 58 or ANSI K61.1; other approvals Per order and certificates; verify with the manufacturer / refer to official manual
Source: Fisher Pressure Regulator Technical Data Supplement, Volume 13 - Check Valves; official G200 Series Back Check Valves Instruction Manual MCK-1146, Types G200 and G201 Replacement Parts Sheet VCIMD-11413-EN, and Bulletin LP-37.

4. Selection Guide

Selection sequence: Service -> Indicator -> Size -> Pressure and temperature -> Installation.

StepItemKey point
1ServiceConfirm LP-Gas or anhydrous ammonia transfer duty
2IndicatorChoose G200 without indicator or G201 with integral flow indicator
3SizeSelect 1-1/4, 2 or 3 in FNPT from the required flow at 10 psig differential
4Pressure and temperatureCheck 400 psi inlet and the -40 to 71 C temperature range
5InstallationObserve the flow arrow and the specified assembly torque

Boundary: Flow tables, torque values and material data follow the official manual and parts sheet; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 13 - Check Valves; official G200 Series Back Check Valves Instruction Manual MCK-1146, Types G200 and G201 Replacement Parts Sheet VCIMD-11413-EN, and Bulletin LP-37.

5. Complete Model Enumeration

ModelSizeDescription
G200-10 / G201-101-1/4 in FNPTBack check valve; G201 adds a flow indicator
G200-16 / G201-162 in FNPTBack check valve; G201 adds a flow indicator
G200-24 / G201-243 in FNPTBack check valve; G201 adds a flow indicator

6. Related Models

Related modelDescription
G100 SeriesCompact back check valve for smaller transfer connections
Type N300 / N400Globe and angle valves for transfer piping
M3162 SeriesClamp hose coupling for transfer hose
Type N551In-line emergency shutoff valve

7. Common Spare Parts

Spare partDescription
Poppet and disc kitReplacement poppet, sliding disc and seat by size
O-ring and X-ring kitSeals by body size, for example 1-1/4 and 3 in sets
SpringReplacement check spring
Flow indicatorReplacement indicator for G201

8. Accessories

AccessoryDescription
Hose couplingConnection to the transfer hose
Pipe nippleAdapter between the valve and the pipeline
StrainerUpstream filtration
Sight gaugeExternal indication where the G200 is used

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 13 - Check Valves; official G200 Series Back Check Valves Instruction Manual MCK-1146, Types G200 and G201 Replacement Parts Sheet VCIMD-11413-EN, and Bulletin LP-37.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area

Energy

Energy

Chemical Industry

Chemical Industry

Mining Industry

Mining Industry

Pharmaceutical Industry

Pharmaceutical Industry

Water treatment industry