Home » Products » Fisher
Fisher L2t Float-Type Liquid Level Controller
Fisher L2t Float-Type Liquid Level Controller
Fisher L2t Float-Type Liquid Level Controller

Fisher L2t Float-Type Liquid Level Controller

Details

1. Product Overview

The Fisher L2t is the digital version of the L2 series of float-type liquid level controllers. It uses a displacer mounted on the side of a vessel and, based on the Archimedes buoyancy principle, converts buoyancy change into a control output through a lever mechanism.

The L2t integrates a sensor and transmitter in one device, providing 4-20 mA output, two discrete limit switches and HART 7 communication. It is pre-calibrated and includes a local user interface.

The controller detects liquid level or liquid-liquid interface and is available with PVC or 316L displacers and a range of process connections.

Above: product appearance / manufacturer literature image.

2. Technical Description

Float-type sensing: Buoyancy displacer detects level or liquid-liquid interface.

Digital output: 4-20 mA plus two discrete limit switches and HART 7.

Accuracy: Analog accuracy +/- 1 percent of full scale; repeatability +/- 0.25 percent of full scale.

Pre-calibrated: Sensor and transmitter supplied pre-calibrated with a local interface.

Materials: PVC or 316L displacer with fluorocarbon O-rings.

Source: Fisher Liquid Level Instrument Introduction; official L2 Series Liquid Level Controller literature.

3. Main Technical Specifications

ParameterSpecification / Description
Instrument typeFloat-type liquid level controller, digital FIELDVUE version
SeriesL2 family: L2 pneumatic, L2e electric, L2sj low emission, L2t digital
Level rangeDefault 71 mm; minimum 102 mm; maximum 305 mm full-output level change
Output signal4-20 mA plus two discrete limit switches and HART 7
Analog accuracy+/- 1 percent of full scale
Repeatability+/- 0.25 percent of full scale
Process temperaturePVC displacer -18 to 71 C; 316L displacer -40 to 204 C
Ambient temperature-29 to 71 C
Enclosure ratingIP66 (cCSAus Type 4X, ATEX and IECEx)
Electrical connectionConduit with LOOP +/- terminals; 24-30 V DC
Process connection2 NPT or NPS 2 CL150-1500 weld-neck flange
Wetted materialsPVC or 316L displacer; fluorocarbon O-ring; stainless steel fulcrum and spring
Displacer options48 x 305 mm and 76 x 152 mm displacers; 6 in and 3 in extension rods
CertificationsATEX / IECEx / cCSAus / NEPSI options per order; Per order and certificates; verify with the manufacturer / refer to official manual
Source: Fisher Liquid Level Instrument Introduction; official L2 Series Liquid Level Controller literature.

4. Selection Guide

Selection sequence: Measurement -> Version -> Displacer -> Process connection -> Options.

StepItemKey point
1MeasurementConfirm level or liquid-liquid interface and the required level span
2VersionChoose L2t for digital 4-20 mA and HART output
3DisplacerSelect PVC or 316L displacer and size by density and level range
4Process connectionChoose 2 NPT or NPS 2 CL150-1500 weld-neck flange
5OptionsSelect extension rod, switches and hazardous-area certification

Boundary: Level ranges, displacer options and approvals follow the official L2 literature; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Liquid Level Instrument Introduction; official L2 Series Liquid Level Controller literature.

5. Complete Model Enumeration

ModelOutputDescription
L2PneumaticPneumatic float-type liquid level controller
L2eElectricElectric version with solid-state contacts
L2sjLow emissionLow-emission pneumatic version
L2tDigital4-20 mA and HART 7 version (this page)

6. Related Models

Related modelDescription
DLC3020fDigital level controller with FOUNDATION fieldbus
DLC3100 / DLC3100 SISDigital level transmitter with 4-20 mA and HART
249 displacer sensorsDisplacer sensors used with digital level instruments
DPC2KDigital process controller for PID control

7. Common Spare Parts

Spare partDescription
DisplacerPVC or 316L replacement displacer
Fulcrum and springStainless steel lever and spring set
O-ring kitFluorocarbon process seal set
Limit switch moduleReplacement discrete switch module

8. Accessories

AccessoryDescription
Mounting flangeNPS 2 weld-neck flange options
Extension rod6 in or 3 in extension
HART communicatorConfiguration and diagnostics
Filter regulatorClean supply where pneumatic options are used

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Liquid Level Instrument Introduction; official L2 Series Liquid Level Controller literature.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area