Fisher FIELDVUE DVC7K Digital Valve Controller
1. Product Overview
The Fisher FIELDVUE DVC7K is a digital valve controller (smart positioner) that converts a 4-20 mA input into a pneumatic output to control a valve actuator. It provides valve diagnostics, a six-key local user interface and HART 7 communication.
Linkage-less, non-contact position feedback removes physical contact between the valve stem and the instrument, eliminating wear and reducing installation parts. A two-stage pneumatic design gives fast response to large steps and precise control of small setpoint changes.
The six-key full-text local user interface supports multiple languages and shows travel, setpoint, instrument mode and valve health. NE 107 LEDs and Advice at the Device help identify valve issues quickly.



2. Technical Description
HART 7: 4-20 mA DC input with HART 7 communication and split-ranging.
Linkage-less feedback: Non-contact position sensing with no mechanical linkage.
Two-stage pneumatic: Fast large-step response with precise small-signal control.
Local UI: Six-key full-text LUI with NE 107 health indication.
Modular design: Key working parts are replaced without removing field wiring or pneumatic tubing.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Instrument type | Digital valve controller (smart positioner) |
| Communication | HART 7 |
| Analog input | 4 to 20 mA DC nominal; split-ranging supported |
| Minimum terminal voltage | 10.2 V DC analog control; 10.7 V DC HART communication |
| Minimum control current | 4.0 mA; 3.8 mA minimum without microprocessor restart; maximum 30 V DC with overcurrent and reverse-polarity protection |
| Output signal | Pneumatic up to full supply pressure; maximum span 9.5 bar / 140 psig |
| Actions | Double acting, single acting reverse, single acting direct |
| Steady air consumption | At 1.4 bar / 20 psig below 0.38 standard m3/h; at 5.5 bar / 80 psig below 1.3 standard m3/h |
| Maximum output capacity | At 1.4 bar 10.0 standard m3/h; at 5.5 bar 29.5 standard m3/h |
| Supply pressure | Minimum 0.3 bar / 5 psig above actuator maximum; maximum 10.0 bar / 145 psig or actuator rating, whichever lower |
| Operating temperature | Standard -40 to +85 C; extreme -45 to +85 C; LUI may be unreadable below -20 C |
| Actuator compatibility | Linear 6.35-606 mm / 0.25-23.375 in; rotary 45-180 degrees (180 degrees needs a special kit) |
| Enclosure | cCSAus Type 4X, IP66; ATEX IP66; IECEx IP66; aluminum housing 3.9 kg / 8.9 lb |
| Certifications | cCSAus, ATEX, IECEx and NEPSI pending depending on construction; Per order and certificates; verify with the manufacturer / refer to official manual |
4. Selection Guide
Selection sequence: Actuator -> Communication -> Supply -> Options -> Approvals.
| Step | Item | Key point |
|---|---|---|
| 1 | Actuator | Confirm linear or rotary actuator, action and travel / rotation |
| 2 | Communication | Choose HART 7 and confirm the control system interface |
| 3 | Supply | Check air quality and a supply at least 0.3 bar above actuator maximum |
| 4 | Options | Select I/O package, LUI language, pneumatic relay and gauge block |
| 5 | Approvals | Choose the hazardous-area certification and electrical / pneumatic connections |
Boundary: Electrical limits, air consumption and approvals follow the DVC7K product bulletin; unlisted values are subject to nameplate / order / official manual.
5. Complete Model Enumeration
| Order field | Example code | Description |
|---|---|---|
| Communication | 1H | HART 7 communication |
| Hazardous approval | 2G / 2D / 2C | CSAus / ATEX / IECEx constructions |
| Pneumatic action | 8C / 8A | Single acting direct / double acting |
| LUI language | EN | English local user interface |
6. Related Models
| Related model | Description |
|---|---|
| DVC6000 series | Earlier FIELDVUE digital valve controllers |
| DVC6200 | FIELDVUE controller with magnetic array feedback |
| DPC2K | Digital process controller for single-loop PID control |
| 67CFR | Filter regulator for clean instrument supply |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Module kit | Replaceable modular working parts |
| Pneumatic relay | Double acting or single acting relay by control tier |
| LUI cover | Polycarbonate local interface cover |
| Filter regulator element | Element for the integral 67CFR option |
8. Accessories
| Accessory | Description |
|---|---|
| Integral filter regulator | Clean, regulated instrument supply |
| 4-20 mA position transmitter | Isolated position feedback with NAMUR NE43 |
| Solid-state switches | Two isolated dry-contact limit switches |
| Gauge block | Supply and output pressure gauges |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文