Fisher Type 3722 Electro-Pneumatic Transducer (I/P)
1. Product Overview
The Fisher Type 3722 is an electro-pneumatic transducer (I/P converter) that converts a 4-20 mA current signal into a proportional pneumatic output using a nozzle-flapper mechanism. It is supplied with the Fisher 3710 and 3720 valve positioners.
The transducer accepts 4-20 mA, 4-12 mA or 12-20 mA split-range inputs and gives a standard 0.2-1.0 bar / 3-15 psig or 0.4-2.0 bar / 6-30 psig output, with zero and span adjustments under the cover.
Reference accuracy is +/- 1.0 percent of full scale including hysteresis, linearity and dead band. Clean, dry instrument air or natural gas is required.



2. Technical Description
I/P transducer: Electro-pneumatic transducer with nozzle-flapper conversion.
Split range: 4-20 mA, 4-12 mA and 12-20 mA inputs via dip switch.
Output ranges: 0.2-1.0 bar, 0.4-2.0 bar or 0.14-2.3 bar.
Accuracy: +/- 1.0 percent full scale reference accuracy.
Low air use: Maximum output 8.0 m3/hr / 300 scfh at 1.4 bar supply.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Instrument type | Electro-pneumatic transducer (I/P, nozzle-flapper) |
| Input signal | Standard 4-20 mA DC; split range 4-12 mA and 12-20 mA by dip switch |
| Output signal | 0.2-1.0 bar / 3-15 psig, 0.4-2.0 bar / 6-30 psig, or 0.14-2.3 bar / 2-33 psig |
| Reference accuracy | +/- 1.0 percent of full scale including hysteresis, linearity and dead band |
| Independent linearity / hysteresis | 0.5 percent / 0.4 percent |
| Temperature effect | +/- 0.14 percent of output range per degree C (+/- 0.075 percent per degree F) |
| Supply pressure effect | 0.2 percent of full scale per 1 psi supply change; vibration below 1 percent of full scale per ISA S75.13 |
| Equivalent circuit | Series circuit with approximately 4 V DC drop and 40 ohm total resistance; two 6.8 V zener diodes |
| Supply pressure | Recommended 0.3 bar / 5 psig above output range maximum; maximum 3.4 bar / 50 psig; air or natural gas |
| Air quality | Clean dry air or natural gas, maximum 40 micrometres (5 micrometres recommended), oil below 1 ppm per ISO 8573-1 |
| Maximum output flow | 8.0 m3/hr / 300 scfh at 1.4 bar supply |
| Connections | Supply, output and vent 1/4 NPT Female; electrical 1/2 NPT, wire 18-22 AWG |
| Enclosure | CSA Type 4X / 3X; FM NEMA 4X / 3; ATEX IP66 / IP64; IECEx IP66 / IP64 |
| Approximate weight | 2.5 kg / 5.5 lb |
4. Selection Guide
Selection sequence: Function -> Input -> Output -> Supply -> Approvals.
| Step | Item | Key point |
|---|---|---|
| 1 | Function | Confirm an I/P conversion duty rather than a full positioner |
| 2 | Input | Choose 4-20 mA, 4-12 mA or 12-20 mA split-range input |
| 3 | Output | Select 3-15 psig, 6-30 psig or 2-33 psig output range |
| 4 | Supply | Provide clean dry air or gas at 0.3 bar above the output maximum, within 3.4 bar |
| 5 | Approvals | Select the enclosure and hazard approval required for the installation |
Boundary: Accuracy, supply limits and air quality follow the official transducer literature; unlisted values are subject to nameplate / order / official manual.
5. Complete Model Enumeration
| Configuration | Input | Description |
|---|---|---|
| 3722 standard | 4-20 mA | Electro-pneumatic transducer with 3-15 psig output (this page) |
| 3722 split range | 4-12 / 12-20 mA | Split-range version set by dip switch |
| 3722 with filter regulator | 4-20 mA | Transducer with Fisher 67 series filter regulator |
6. Related Models
| Related model | Description |
|---|---|
| 3710 | Pneumatic valve positioner used with the 3722 transducer |
| 3720 | Electro-pneumatic valve positioner used with the 3722 transducer |
| 646 / 846 | Electro-pneumatic transducers in the Fisher range |
| i2P-100 / 546NS | Other Fisher current-to-pressure transducers |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Nozzle and flapper assembly | Replacement nozzle-flapper element |
| Zero / span potentiometer | 20-turn adjustment potentiometer |
| Diaphragm and seals | Elastomer service kit |
| Filter element | Replacement element for the supply filter |
8. Accessories
| Accessory | Description |
|---|---|
| 67 series filter regulator | Clean, regulated instrument supply |
| 2 in supply gauge | Circular supply pressure gauge |
| Explosion-proof housing | Hazardous-area enclosure and cover |
| Pipe fittings | 1/4 NPT pneumatic fittings |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文