Home » Products » Fisher
Fisher FIELDVUE DVC6010 Digital Valve Controller
Fisher FIELDVUE DVC6010 Digital Valve Controller
Fisher FIELDVUE DVC6010 Digital Valve Controller

Fisher FIELDVUE DVC6010 Digital Valve Controller

Details

1. Product Overview

The Fisher FIELDVUE DVC6010 is a digital valve controller (smart positioner) in the DVC6000 family. It converts a 4-20 mA input signal into a pneumatic output to drive a control valve actuator and uses non-contact Hall-effect position feedback.

The DVC6010 is intended for direct mounting on linear sliding-stem actuators. It supports HART communication, split-ranging and local configuration, and can be set up and diagnosed with a HART communicator or ValveLink software.

A linkage-less feedback arrangement removes mechanical contact between the valve stem and the instrument, reducing wear and simplifying installation.

Above: product appearance / manufacturer literature image.

2. Technical Description

Digital valve controller: Smart positioner with 4-20 mA HART input and pneumatic output.

Linear actuators: Direct mounting on sliding-stem actuators with feedback arm.

Non-contact feedback: Hall-effect position sensing without mechanical linkage.

Output: Pneumatic output up to approximately 95 percent of supply pressure.

Mounting standards: IEC 60534-6-1 / 6-2, VDI/VDE 3845 and NAMUR.

Source: Fisher Valve Positioner Product Selection Literature; official DVC6000 Series Digital Valve Controller Instruction Manual.

3. Main Technical Specifications

ParameterSpecification / Description
Instrument typeDigital valve controller (smart positioner), DVC6000 family
ModelDVC6010 for linear sliding-stem actuators
Input signal4-20 mA DC, nominal; split-ranging supported; HART communication
Loop voltageMinimum approximately 8.5 V DC (9.0 V DC for HART) per DVC6000 product sample
Maximum supply pressure7 bar / 100 psig for standard DVC6000 construction; confirm higher ratings with the official manual
Output signalPneumatic output up to approximately 95 percent of supply pressure
Stroke rangeLinear 6.35-606 mm / 0.25-23.375 in
Position feedbackNon-contact Hall-effect sensor with feedback arm kit GG09947X012
Independent linearityTypical +/- 0.5 percent of output span; verify exact figure with the official manual
Operating temperature-40 to +85 C; LCD may be unreadable below -20 C
Enclosure ratingNEMA 4X / CSA Type 4X / IEC 60529 IP66
Electrical connection1/2 NPT Female; M20 optional
Pneumatic connectionSupply and output 1/4 NPT; G1/4 optional
CertificationsHazardous-area approvals vary by construction; Per order and certificates; verify with the manufacturer / refer to official manual
Source: Fisher Valve Positioner Product Selection Literature; official DVC6000 Series Digital Valve Controller Instruction Manual.

4. Selection Guide

Selection sequence: Actuator -> Signal -> Supply pressure -> Feedback -> Options.

StepItemKey point
1ActuatorConfirm a linear sliding-stem actuator and the required stroke
2SignalChoose 4-20 mA with HART and any split-range requirement
3Supply pressureCheck instrument air quality and maximum supply pressure
4FeedbackSelect the DVC6010 feedback arm kit for the actuator travel
5OptionsAdd position transmitter, limit switches or a filter regulator as needed

Boundary: Loop voltage, supply ratings and linearity figures follow the DVC6000 product sample; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Valve Positioner Product Selection Literature; official DVC6000 Series Digital Valve Controller Instruction Manual.

5. Complete Model Enumeration

ModelActuatorDescription
DVC6010Linear sliding stemDigital valve controller with feedback arm (this page)
DVC6015Linear, remote mountRemote-mount version with magnet strip feedback
DVC6020Rotary / linearDigital valve controller with long feedback arm
DVC6030Double actingDigital valve controller for double-acting actuators

6. Related Models

Related modelDescription
DVC6020Digital valve controller for rotary and long-travel applications
DVC6030Digital valve controller for double-acting actuators
DVC6200FIELDVUE digital valve controller with magnetic array feedback
DVC7KNewer FIELDVUE digital valve controller with HART 7

7. Common Spare Parts

Spare partDescription
Feedback arm kitGG09947X012 for DVC6010 travel sensor
I/P converter kit38B6041X152 standard I/P converter
Cover kit38B9580X022 aluminum or 38B9580X042 stainless
Elastomer kitNBR or fluorosilicone seal set

8. Accessories

AccessoryDescription
67CFR filter regulatorClean, regulated instrument supply
Position transmitter4-20 mA isolated position feedback
Limit switchesTwo independent solid-state switches
HART communicator / ValveLinkConfiguration and diagnostics

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Valve Positioner Product Selection Literature; official DVC6000 Series Digital Valve Controller Instruction Manual.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area