Home » Products » Fisher
Fisher CT88 High-Capacity Backpressure Regulator
Fisher CT88 High-Capacity Backpressure Regulator
Fisher CT88 High-Capacity Backpressure Regulator

Fisher CT88 High-Capacity Backpressure Regulator

Details

1. Product Overview

The Fisher Type CT88 is a high-capacity backpressure regulator for liquid, air and gas service. It uses a pressure-loaded actuator with external pressure registration and provides quick-open flow characteristics with ANSI Class VI shutoff.

Six spring ranges cover set pressures from 3 to 150 psig / 0.21 to 10.3 bar. The carbon steel body, fluorocarbon diaphragm and 316 stainless steel trim suit lube oil, cooling water and similar industrial services.

The regulator is designed for use where a large flow capacity is needed in a compact flanged body.

Above: product appearance / manufacturer literature image.

2. Technical Description

High capacity: Cg 138 from A to B and 131 from A to C.

Six spring ranges: Set pressures from 3 to 150 psig / 0.21 to 10.3 bar.

Quick open: Quick-open flow characteristic.

Class VI shutoff: ANSI / FCI 70-3 Class VI soft shutoff.

Industrial materials: WCB carbon steel body, FKM diaphragm and 316 stainless trim.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 03 - Backpressure, Relief and Vent Valves; official Type CT88 Backpressure Regulator Instruction Manual D104030X012.

3. Main Technical Specifications

ParameterSpecification / Description
Valve typeHigh-capacity backpressure regulator
Body sizesNPS 2 / DN 50, NPS 3 / DN 80, NPS 4 / DN 100
Flow coefficientsCg A to B 138; Cg A to C 131; C1 A to B 28.0; C1 A to C 32.5, measured at 25 psig / 1.7 bar inlet with full body pressure drop
Maximum inlet pressure150 psig / 10.3 bar
Maximum control pressure to diaphragm150 psig / 10.3 bar
Set pressure ranges3 to 150 psig / 0.21 to 10.3 bar in six spring ranges (official Table 1)
Control connection1/4 NPT
Pressure registrationExternal
Flow characteristicQuick open
Shutoff classANSI / FCI 70-3 Class VI
Body materialCarbon steel (WCB)
Trim and diaphragm316 stainless steel trim; fluorocarbon (FKM) diaphragm and seals
Temperature capabilityFKM -7 to 120 C; hot water limited to 93 C
Approximate weight5 lb / 2.3 kg
Source: Fisher Pressure Regulator Technical Data Supplement, Volume 03 - Backpressure, Relief and Vent Valves; official Type CT88 Backpressure Regulator Instruction Manual D104030X012.

4. Selection Guide

Selection sequence: Service -> Set pressure -> Capacity -> Inlet limit -> Connections.

StepItemKey point
1ServiceConfirm liquid, air or gas backpressure duty and media compatibility
2Set pressureSelect one of the six spring ranges between 3 and 150 psig
3CapacityCheck Cg and C1 against required flow and inlet pressure
4Inlet limitVerify the 150 psig maximum inlet and diaphragm control pressure
5ConnectionsChoose NPS 2-4 and arrange the 1/4 NPT external control line

Boundary: Set ranges, flow coefficients and temperature limits follow the official manual; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 03 - Backpressure, Relief and Vent Valves; official Type CT88 Backpressure Regulator Instruction Manual D104030X012.

5. Complete Model Enumeration

ModelSizeDescription
CT88 NPS 2NPS 2 / DN 50High-capacity backpressure regulator (this page)
CT88 NPS 3NPS 3 / DN 80Higher capacity body
CT88 NPS 4NPS 4 / DN 100Highest capacity body

6. Related Models

Related modelDescription
MR108Direct-operated backpressure regulator for smaller line sizes
MR105Direct-operated liquid pressure reducing regulator
92WPilot-operated liquid pressure reducing regulator
67CFR SeriesFilter regulator for instrument supply

7. Common Spare Parts

Spare partDescription
Diaphragm kitFKM diaphragm and seals
SpringBy set pressure range
Seat and plug kit316 stainless trim by body size
Control line fitting1/4 NPT external sensing fitting

8. Accessories

AccessoryDescription
Pressure gaugeUpstream pressure indication
External control line1/4 NPT sensing tubing
FilterUpstream filtration
Vent lineActuator vent piped to a safe location

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Pressure Regulator Technical Data Supplement, Volume 03 - Backpressure, Relief and Vent Valves; official Type CT88 Backpressure Regulator Instruction Manual D104030X012.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area