Home » Products » Fisher
Fisher Type T208VR Direct-Operated Vacuum Regulator
Fisher Type T208VR Direct-Operated Vacuum Regulator
Fisher Type T208VR Direct-Operated Vacuum Regulator

Fisher Type T208VR Direct-Operated Vacuum Regulator

Details

1. Product Overview

The Fisher Type T208VR is a direct-operated vacuum regulator for controlling vacuum in small-capacity systems. It reduces an upstream vacuum to a controlled downstream vacuum using a spring-loaded diaphragm and a 7/16 in / 11 mm orifice.

The regulator is available in gray cast iron, WCC or LCC carbon steel and CF8M or CF3M stainless steel, with NPT or CL150 RF connections. All flanges are welded with a 14 in / 356 mm face-to-face dimension.

Maximum emergency vacuum is full vacuum and maximum operating vacuum is 11 psig / 0.76 bar vacuum.

Above: product appearance / manufacturer literature image.

2. Technical Description

Direct operation: Spring-loaded diaphragm regulates downstream vacuum.

Small orifice: 7/16 in / 11 mm stainless steel orifice.

Full vacuum capable: Maximum emergency vacuum is full vacuum.

Stainless internals: 316 stainless steel orifice, pusher post, stem and disk holder.

Flexible materials: Cast iron, carbon steel or stainless steel bodies.

Source: Fisher Vacuum Service Equipment Technical Data; official Type T208VR Instruction Manual D103760X012.

3. Main Technical Specifications

ParameterSpecification / Description
Valve typeDirect-operated vacuum regulator
Body sizesNPS 3/4 or 1 / DN 20 or 25
End connectionsGray cast iron NPT; CF8M / CF3M stainless, WCC and LCC carbon steel NPT or CL150 RF welded flange
Orifice7/16 in / 11 mm, 316 stainless steel
Maximum casing pressureGray cast iron 35 psig / 2.41 bar; WCC / LCC carbon steel and CF8M / CF3M 75 psig / 5.17 bar
Maximum emergency inlet to avoid damage35 psig / 2.41 bar
Maximum emergency vacuumFull vacuum
Maximum operating vacuum11 psig / 0.76 bar vacuum
Maximum downstream vacuumFull vacuum per official instruction manual
Pressure registrationInternal
InternalsDiaphragm heads 304 SS; pusher post 316 SS; stem 316 SS; lever 302 SS; adjusting nut brass
Diaphragm materialNBR standard or FKM
Seal materialNBR or FKM body / insert seal O-ring
Face-to-face14 in / 356 mm for welded flanges
Source: Fisher Vacuum Service Equipment Technical Data; official Type T208VR Instruction Manual D103760X012.

4. Selection Guide

Selection sequence: Duty -> Body and connection -> Vacuum limits -> Casing pressure -> Elastomers.

StepItemKey point
1DutyConfirm vacuum regulation duty and required downstream vacuum
2Body and connectionSelect NPS 3/4 or 1 and NPT or CL150 RF welded flange
3Vacuum limitsCheck full vacuum emergency rating and 11 psig operating vacuum limit
4Casing pressureVerify casing rating for the selected body material
5ElastomersChoose NBR or FKM diaphragm and seals by service

Boundary: Vacuum limits, casing ratings and connections follow the official manual; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Vacuum Service Equipment Technical Data; official Type T208VR Instruction Manual D103760X012.

5. Complete Model Enumeration

ModelMaterialDescription
T208VR cast ironGray cast ironDirect-operated vacuum regulator (this page)
T208VR carbon steelWCC / LCCVacuum regulator with carbon steel body
T208VR stainlessCF8M / CF3MVacuum regulator with stainless steel body

6. Related Models

Related modelDescription
T205VBDirect-operated vacuum breaker
Y692VBLow-pressure vacuum breaker
66 series vacuum regulatorDirect-operated vacuum regulating equipment
T205 seriesTank blanketing and vacuum protection regulators

7. Common Spare Parts

Spare partDescription
DiaphragmNBR or FKM diaphragm
Orifice7/16 in 316 stainless steel orifice
Disk holder assembly316 stainless with NBR or FKM disk
Seal O-ringNBR or FKM body / insert seal

8. Accessories

AccessoryDescription
Pressure gaugeVacuum indication
Pipe fittingsNPT and welded flange fittings
FilterUpstream filtration
Sealing wireTamper-resistant adjustment

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Vacuum Service Equipment Technical Data; official Type T208VR Instruction Manual D103760X012.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area