Home » Products » Fisher
Fisher T205VB Series Vacuum Breaker
Fisher T205VB Series Vacuum Breaker
Fisher T205VB Series Vacuum Breaker

Fisher T205VB Series Vacuum Breaker

Details

1. Product Overview

The Fisher T205VB series is a direct-operated vacuum breaker for small-capacity, low-pressure applications where vacuum rise must be limited. When vacuum on the diaphragm exceeds the setpoint, the valve opens to admit atmosphere or positive pressure and stop a further vacuum rise.

Two constructions are available: Type T205VB with internal registration and no downstream control line, and Type T205VBM with a blocked throat, O-ring stem seal and external control line.

Large diaphragm area gives accurate control at low vacuum, and common spare parts are shared with other T205 series devices. Multiple body materials provide corrosion resistance.

Above: product appearance / manufacturer literature image.

2. Technical Description

Direct operation: Vacuum acting on the diaphragm opens the valve at the setpoint.

Two constructions: T205VB internal registration, T205VBM external registration.

Large diaphragm: Accurate low-vacuum control.

Tamper resistant: Adjusting nut with optional sealing wire.

Materials: Gray cast iron, carbon steel or stainless steel bodies.

Source: Fisher Vacuum Service Equipment Technical Data; official Bulletin 71.3:T205VB D103757X012 and Instruction Manual D103759X012.

3. Main Technical Specifications

ParameterSpecification / Description
Valve typeDirect-operated vacuum breaker
ConfigurationsT205VB internal registration; T205VBM external registration with blocked throat and O-ring stem seal
Body sizesNPS 3/4 / DN 20 and NPS 1 / DN 25
End connectionsCast iron NPT; WCC / LCC carbon steel or CF8M / CF3M stainless steel NPT or 3/4 x 1 CL150 RF welded flange
Orifice sizes1/4 in / 6.4 mm and 1/2 in / 13 mm
Body inlet pressure ratingGray cast iron 150 psig / 10.3 bar; stainless steel 200 psig / 13.8 bar
Maximum operating inlet pressure150 psig / 10.3 bar
Maximum outlet (casing) pressureGray cast iron 35 psig / 2.41 bar; carbon and stainless steel 75 psig / 5.17 bar
Maximum emergency outlet pressure35 psig / 2.41 bar
Maximum vacuum pressureFull vacuum
Vacuum control range0-4 in w.c. / 0-10 mbar and 0-1.0 psig / 0-69 mbar, plus other spring ranges (official Table 1)
Spring case / diaphragm case connection1/4 NPT / 1/2 NPT
Temperature capabilityNBR -29 to 82 C (gray iron / WCC) or -40 to 82 C (LCC / CF8M / CF3M); FKM 4 to 149 C
Approximate weight18.7 lb / 8.5 kg
Source: Fisher Vacuum Service Equipment Technical Data; official Bulletin 71.3:T205VB D103757X012 and Instruction Manual D103759X012.

4. Selection Guide

Selection sequence: Duty -> Registration -> Body and connection -> Orifice and spring -> Materials.

StepItemKey point
1DutyConfirm vacuum breaking duty and the required vacuum setpoint
2RegistrationChoose T205VB internal or T205VBM external registration
3Body and connectionSelect NPS 3/4 or 1 and NPT or CL150 RF welded flange
4Orifice and springChoose 1/4 or 1/2 in orifice and a vacuum control spring range
5MaterialsSelect cast iron, carbon steel or stainless steel and NBR or FKM elastomers

Boundary: Vacuum ranges, casing limits and connections follow the official bulletin; unlisted values are subject to nameplate / order / official manual.

Source: Fisher Vacuum Service Equipment Technical Data; official Bulletin 71.3:T205VB D103757X012 and Instruction Manual D103759X012.

5. Complete Model Enumeration

ModelRegistrationDescription
T205VBInternalDirect-operated vacuum breaker (this page)
T205VBMExternalBlocked-throat version with control line and O-ring stem seal
T205VB stainlessMaterialCF8M / CF3M stainless steel construction

6. Related Models

Related modelDescription
T208VRDirect-operated vacuum regulator
Y692VBLow-pressure vacuum breaker
66 series vacuum equipmentVacuum regulator and vacuum breaker devices
T205 seriesTank blanketing regulators sharing common spare parts

7. Common Spare Parts

Spare partDescription
DiaphragmNBR or FKM diaphragm
Orifice1/4 or 1/2 in replacement orifice
SpringVacuum control spring by range
O-ring stem sealFor T205VBM external-registration construction

8. Accessories

AccessoryDescription
Control lineExternal registration tubing for T205VBM
Pressure gaugeVacuum indication
Sealing wireTamper-resistant adjustment
Pipe fittingsNPT and flanged installation fittings

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Fisher Vacuum Service Equipment Technical Data; official Bulletin 71.3:T205VB D103757X012 and Instruction Manual D103759X012.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area