Home » Service & Support » Technical Documentation
AUMA Electric Actuators - Bus Integration & Position Feedback
Release time:2026-11-24 14:01:02 | Views:

AUMA electric actuators use the AC 01.2 / ACExC 01.2 actuator controls as the core, offering fieldbus interfaces including PROFIBUS DP/DP-V2, PROFINET, Modbus RTU/TCP, HART, FOUNDATION Fieldbus and WirelessHART, with non-intrusive setting and position/torque feedback via the MWG magnetic limit and torque transmitter. This article covers the bus protocol comparison, position feedback capability and integration points based on official AUMA product pages.

I. Product Positioning

ItemContent
Brand ownershipAUMA, an independent brand, not part of Emerson, Honeywell, Rotork, etc.
Core controlsAC / ACV actuator controls (AC 01.2), supporting self-adapting control functions, data logging, configurable interfaces and integration into plant asset management systems
Bus capabilityPROFIBUS DP/DP-V2, PROFINET, Modbus RTU/TCP, HART, FOUNDATION Fieldbus, WirelessHART; interfaces available with component redundancy
Position feedbackLimit and torque available as analogue signals (with MWG magnetic limit and torque transmitter); programmable potential-free output contacts for status signalling
Main documentsAUMA official AC/ACV product page p35462, AC-SIL page p35463, Fieldbus page p35458

The data in this article was obtained via web search. Source: AUMA official AC/ACV product page https://auma.com/en_GB/products/ac-p35462 , AC-SIL page https://auma.com/en_US/solutions/market-segments/water/ac-silacexc-sil-p35463 , Fieldbus page (document p35458).

Electric actuator illustration
Electric actuator illustration, not an AUMA product; parameters subject to the official data sheet

II. Bus Protocol Comparison

ProtocolPhysical layer / versionFeatures (extract)
PROFIBUS DPRS-485; DP-V0 / V1 / V2DP-V0 fast deterministic cyclic data; DP-V1 acyclic access to parameters and diagnostics; DP-V2 time stamping and redundancy
PROFINETIndustrial EthernetEthernet-based automation communication, suitable for integration with PLC/SIMATIC systems
Modbus RTU / TCPRS-485 (RTU) / Ethernet (TCP)Simple and widely used; exchanges digital information, analog values, parameters and diagnostic data; TCP eases integration into upper-level systems
HART / WirelessHARTDigital signal superimposed on 4-20 mA / wirelessReads parameters and diagnostics over existing 4-20 mA infrastructure; wireless for condition monitoring
FOUNDATION Fieldbus H1IEC 61158-2, ISA SP 50.02Standard function blocks (AI/AO etc.) can be linked; requires a Link Active Scheduler (LAS); supports bus powering and multiple topologies

Select the bus by the project's existing network and control system first, then by the required data volume (switch feedback, analog position, torque, diagnostics) and whether redundancy is needed. AUMA fieldbus interfaces can use component redundancy and behavior on communication loss is configurable.

The data in this article was obtained via web search. Source: AUMA official Fieldbus page (document p35458) and AC/ACV product page https://auma.com/en_GB/products/ac-p35462 ; standards per IEC 61158-2 / ISA SP 50.02.

III. AC 01.2 Control and Interface Capabilities

CapabilityDescription
Control inputsControl inputs of different voltages (DC/AC); analogue control 0/4-20 mA
Output signalsProgrammable potential-free output contacts for status signalling; limit and torque as analogue signals (with MWG)
Control functionsProgrammable stepping mode (for extended running time), freely defined intermediate positions, process controller (PID)
Non-intrusive settingWith MWG magnetic limit and torque transmitter, setting and parametrization without opening covers
Commissioning toolsLarge graphic display for menu programming; optional AUMA CDT via Bluetooth (laptop/Android tablet); with fieldbus connection, programming can be done from the control room

The modular interface design of AC 01.2 eases remote control and DCS integration; operating data logging includes time-stamped event reports, torque characteristic logging, continuous recording of temperatures and vibration, counting of starts and motor running times.

The data in this article was obtained via web search. Source: AUMA official AC/ACV product page https://auma.com/en_GB/products/ac-p35462 ; functions subject to the corresponding model manual.

IV. Position Feedback and Safety Functions

ItemCapability (extract)
Conventional position feedbackLimit and torque output as analogue signals via MWG transmitter; programmable potential-free contacts for status signalling
Safe end position feedbackUp to SIL 2 in selected configurations (per IEC 61508 Ed. 2); up to SIL 3 in redundant setups (e.g., 1oo2) with AC-SIL
Safety functionsSafe OPENING/CLOSING (ESD) up to SIL 2 single-channel, SIL 3 redundant; Safe STOP up to SIL 2
Safe seating typesForced limit seating in end position, forced limit seating with overload protection, forced torque seating, no seating for safety operation
ApprovalsAC-SIL / ACExC-SIL TÜV certified; Ex versions marked Ex de IIC/IIB T4 (T3), Ex d IIC/IIB T4 (T3), ATEX/IECEx/FM

Safe feedback capability depends on the specific configuration, redundancy architecture and certificate scope; it does not mean any combination carries SIL 3. Verify against project safety requirements and original certificates; if not found, state "unable to confirm, please verify with the manufacturer".

The data in this article was obtained via web search. Source: AUMA official AC-SIL/ACExC-SIL page https://auma.com/en_US/solutions/market-segments/water/ac-silacexc-sil-p35463 ; approvals subject to TÜV certificates and nameplate.

V. Integration and Operating Environment

ItemPoints
Protection and environmentIP68 enclosure protection; KS corrosion protection; AC standard ambient -30 C to +70 C (AC-SIL page additionally -25 C to +40/+60 C)
Electrical connectionAUMA plug/socket connector (terminals as alternative); various cable entry versions; FOC connection available for fieldbus interfaces
Power supplyExternal 24 V DC supply (option); phase monitoring with automatic phase correction; motor control via reversing contactors or thyristors
Communication lossBehavior in emergencies and on communication loss is programmable and must be set per process safety requirements during commissioning
MaintenanceOperating data logging and diagnostics support predictive maintenance; Bluetooth CDT eases on-site parameter reading and modification

Ex ia intrinsic safety is NOT Ex d flameproof; the Ex marking and temperature class of Ex versions such as ACExC must be checked against the nameplate and certificates. If an approval cannot be found, state "unable to confirm, please verify with the manufacturer".

The data in this article was obtained via web search. Source: AUMA official AC/ACV product page https://auma.com/en_GB/products/ac-p35462 and AC-SIL page https://auma.com/en_US/solutions/market-segments/water/ac-silacexc-sil-p35463 ; specific models subject to the corresponding manual/nameplate.

VI. Selection Guide and Common Models

Selection guide: First determine the actuator body (multi-turn SA .2 / quarter-turn SQ .2, etc.) and the actuator controls (AC 01.2 / ACExC 01.2 / AC-SIL version), then select the bus (PROFIBUS DP/PROFINET/Modbus/FF/HART, etc.) per the project network and check whether component redundancy is needed; then confirm the position/torque feedback method (MWG analogue, potential-free contacts, bus diagnostics) and safety function level (SIL 2 / SIL 3 and related approvals); finally verify protection, temperature, electrical interface and communication-loss behavior. If an approval or combination cannot be confirmed, state "unable to confirm, please verify with the manufacturer".

Common models: AUMA AC / ACV actuator controls (AC 01.2 series); AC-SIL / ACExC-SIL safety versions; SA .2 multi-turn and SQ .2 quarter-turn actuators; MWG magnetic limit and torque transmitter; AUMA CDT Bluetooth commissioning tool. Specific ordering codes, bus interfaces and approvals follow the nameplate and original manual.

If you are integrating an AUMA actuator into a bus network or verifying position feedback, please send us the control system protocol, required feedback points and site network topology. We can review the bus type, feedback method and safety level item by item against the official product pages.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.