Home » Service & Support » Technical Documentation
Honeywell BX / BX2 - Spare Parts & Accessories List
Release time:2026-11-24 13:40:51 | Views:

Honeywell BX / BX2 flameproof limit switches may require replacement or optional parts over their service life: operating heads, levers, switching elements, seals and conduit entries. The official documentation states that replacement parts must be approved by Honeywell, levers must be non-sparking, and flameproof plugs/glands must be certified. Most part numbers are not listed item by item in public documents and must be confirmed against the nameplate, official manual and order. This article summarizes the verifiable spare-parts and accessories basis from Honeywell official data sheets and installation instructions.

I. Product Positioning

ItemContent
Brand ownershipHoneywell MICRO SWITCH; BX / BX2 belong to the Honeywell brand
Model differencesBX = aluminum housing; BX2 = 316L stainless steel housing; both are flameproof Ex d (Ex db IIC T6 Gb / Ex tb IIIC T85 C Db)
Spare-parts principleDo not substitute parts from another switch without consulting Honeywell technical support; levers must be non-sparking
Interfaces and protectionConduit 1/2"-14 NPT, 3/4"-14 NPT, 20 mm; IP67, NEMA 1/3/4/6/13 (BX2 additionally 4X)
Main documentsHoneywell official data sheet 002306 Issue 11; BX installation instructions 50083427; BX2 installation instructions 50047766

The data in this article was obtained via web search. Source: Honeywell official data sheet 002306 Issue 11, BX installation instructions 50083427, BX2 installation instructions 50047766; standards IEC 60079-0, IEC 60079-1, IEC 60079-31.

Limit switch illustration
Limit switch illustration, not a Honeywell product; parameters subject to the official data sheet

II. Replaceable Parts and Spare-parts List

PartFunction and applicabilityPart-number status
Switching elementAccessible after removing the cover for wiring or replacement; double-pole/single-pole per original configurationPart numbers not listed item by item in public documents; subject to official manual/order
Operating headMountable in four positions; side-rotary type actuation direction can be changed, cam set point adjusted hereVerify by model and head type; subject to official manual/order
Lever / roller leverRotary lever adjustable through 360 degrees; only non-sparking levers may be used to retain flameproof qualitiesSelect by model; please verify with the manufacturer
Cam assemblyDetermines set point and actuation direction; must be recalibrated after replacementPart number subject to official manual
Cover and cover locking clampCover reassembly torque 10 Nm (90 lb-in); clamp 1.4 Nm to 1.8 NmVerify by housing model
Head screws / ground screwsHead screws 1.4 Nm to 1.8 Nm; terminal and ground screws 1 Nm to 1.8 NmSubject to official manual/nameplate
Plugs for unused openingsUnused openings on flameproof equipment must be closed with certified plugsMust be certified; order by conduit thread, please verify
Seals / O-ringsFluorosilicone -40 to +70 C; fluorocarbon -12 to +70 C (depends on seal material)Select by temperature and medium; subject to official data sheet

The table above lists verifiable spare-part categories, not a complete original spare-parts catalogue. Where public documents do not list a part number, state "subject to the official manual/nameplate / please verify with the manufacturer" and never guess a part number.

The data in this article was obtained via web search. Source: Honeywell official BX2 installation instructions 50047766, Wiring Instructions, Replacement Levers and Mounting sections; BX installation instructions 50083427; data sheet 002306 Issue 11; unlisted items to be verified.

III. Adjustment Tools and Optional Accessories

Tool / accessoryPurposeNotes
LSZ4005 adjustment tool setIncludes a 9/64-inch hex key for lever angle and adjustable-length lever settingTool number explicitly listed in the installation instructions
9/64-inch hex keyLoosen/tighten lever clamping screwSupplied with LSZ4005; separate ordering subject to official catalogue
Non-sparking replacement leverRetains flameproof qualities for damaged or changed leversOnly non-sparking type allowed; specific model to be verified
NAMUR mounting bracket / interface plateMounts the switch to actuators with VDI/VDE 3845 or ISO 5211 interfaceVerify against actuator interface; subject to official data sheet
Conduit glandsMatch 1/2", 3/4" NPT or 20 mm conduitFor flameproof applications must be certified flameproof glands
Labels and wiring accessoriesPre-wired numbered terminal block, sealing plugsVerify against nameplate circuit diagram and ordering code

Accessories relate to approvals: not every combination carries every approval. ATEX/IECEx/CCC Ex/NEPSI certificates must be checked against the specific ordering code and nameplate; if not found, state "unable to confirm, please verify with the manufacturer".

The data in this article was obtained via web search. Source: Honeywell official BX2 installation instructions 50047766 (LSZ4005, non-sparking levers, conduit size) and data sheet 002306 Issue 11 (Termination types, approvals); unlisted part numbers to be verified.

IV. Ordering Code and Compatibility Check

Check itemOptionsSelection points
Housing materialBX aluminum / BX2 316L stainless steelPrefer BX2 for corrosive or wash-down environments
Conduit entry1/2"-14 NPT, 3/4"-14 NPT, 20 mmMust match site conduit/gland; flameproof glands must be certified
Seal materialFluorosilicone -40 to +70 C; fluorocarbon -12 to +70 CSelect by minimum ambient temperature
Electrical ratings10 A continuous; AC15 A600, DC13 R300; 24 VDC inductive/resistive 10 A eachLoad current and type shown on nameplate
ProtectionIP67; NEMA 1/3/4/6/13 (BX2 additionally 4X)Verify for outdoor and wash-down environments

BX and BX2 belong to the same flameproof platform but housing material and approval coverage may differ; the data sheet lists approvals separately by model and interface. Check each item before ordering and do not assume a given model holds every approval.

The data in this article was obtained via web search. Source: Honeywell official data sheet 002306 Issue 11, Termination types, electrical ratings and Agency Certifications tables; subject to nameplate and original certificates.

V. Spare-parts Replacement and Ex Precautions

ItemRequirement
Part sourceDo not substitute parts from another switch without consulting Honeywell technical support
Lever materialUse only non-sparking levers, otherwise the flameproof qualities are compromised
Cover openingNever open a flameproof enclosure while energized; restore threads and seals after maintenance
Flame pathsMax gap at plunger and bearing 0.076 mm, bearing and housing 0.02 mm (cylindrical spigot); keep intact
Reassembly torqueHead screws 1.4 Nm to 1.8 Nm; terminal/ground screws 1 Nm to 1.8 Nm; cover 10 Nm; locking clamp 1.4 Nm to 1.8 Nm

Ex db flameproof is NOT Ex ia intrinsic safety: flameproof relies on an enclosure that withstands internal explosion and cools escaping gases through flame paths, while intrinsic safety limits circuit energy. Spare-parts replacement must not alter the flame path, sealing or grounding structure. If a certificate or part number cannot be found, state "unable to confirm, please verify with the manufacturer".

The data in this article was obtained via web search. Source: Honeywell official BX2 installation instructions 50047766, warnings, flame-path table and torque requirements; BX installation instructions 50083427; subject to the official manual.

VI. Selection Guide and Common Models

Selection guide: First determine the exact model required (BX aluminum or BX2 stainless steel), conduit entry and seal temperature class, then confirm contact form and electrical ratings from the nameplate circuit diagram. For spare parts, select only Honeywell-approved parts, levers must be non-sparking, and flameproof plugs/glands must be certified. Where public documents do not list a part number, state "subject to the official manual/nameplate / please verify with the manufacturer" and never guess part numbers. Ex ia intrinsic safety is NOT Ex d flameproof and must not be mixed.

Common models: BXA3K (BX aluminum side-rotary SPDT, 1/2" NPT), BXAC3K (fully fluorocarbon sealed); the BX2 series uses a 316L stainless steel housing. LSZ4005 is the official adjustment tool set. Specific ordering codes, spare-part numbers and certificates follow the nameplate and original catalogue; if not found, state "unable to confirm, please verify with the manufacturer".

If you need replacement or optional parts for in-service BX/BX2 units, please send us the nameplate, ordering code and a photo of the damaged part. We can review the part category, conduit thread and Ex requirements item by item against the official manual to avoid mismatches.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.