| Fisher Valve Seat Leakage Classes & Seal Testing Points | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-24 09:02:41 | Views: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Valve seat leakage classes define the permitted internal leakage through a fully closed valve. The commonly used standards are ANSI/FCI 70-2 and IEC 60534-4. Classes II to IV are expressed as a percentage of rated capacity, Class V per inch of port diameter per psi differential, and Class VI by bubble count. This article summarizes the six classes, test conditions, typical Fisher trim capabilities and the difference between factory tests and service conditions. I. Product Positioning
The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; specific values are subject to the standard and Fisher official data sheets.
II. Six Leakage Class Definitions
The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; subject to the standard; no class values are assumed. III. Test Methods and Conditions
The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; online diagnostic methods are subject to instrument manufacturer manuals. IV. Typical Fisher Trim Capabilities
Source: Fisher D100017X012, D100023X012, D101554X012 and D102630X012 leakage tables; the final class is subject to the ordering code and factory test report. V. Selection Guide and Common ModelsSelection guide: Set the class by medium hazard and shutoff duty (toxic, flammable or clean gas service often needs Class VI), then check whether temperature and differential allow a soft seat. Metal seats generally achieve Class IV / V; soft seats can reach Class VI. Do not default to Class VI without weighing the temperature ceiling, service life and cost; where a class is not documented, refer to the official data sheet. Common models: easy-e ET / EZ / ED, Vee-Ball V150 / V200 / V300 and 63EG-98HM; testing per ANSI/FCI 70-2 / IEC 60534-4. If you need to verify the leakage class and factory test conditions of a control valve, please send us the valve type, seat material and service conditions. We can cross-check them against the Fisher official data sheet and the standard to avoid a wrong class selection. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |