Valve seat leakage classes define the permitted internal leakage through a fully closed valve. The commonly used standards are ANSI/FCI 70-2 and IEC 60534-4. Classes II to IV are expressed as a percentage of rated capacity, Class V per inch of port diameter per psi differential, and Class VI by bubble count. This article summarizes the six classes, test conditions, typical Fisher trim capabilities and the difference between factory tests and service conditions.

I. Product Positioning

ItemContent
Brand / ownershipFisher, an Emerson brand (trims and sealing solutions)
TopicValve seat leakage classes and seal testing points
StandardsANSI/FCI 70-2; identically adopted as IEC 60534-4; pressure testing also API 598
DistinctionSeat leakage is not stem fugitive emission (ISO 15848) and not shell leakage (API 598)
SourceANSI/FCI 70-2 / IEC 60534-4; Fisher series bulletins leakage tables

The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; specific values are subject to the standard and Fisher official data sheets.

Illustration, not the exact model
Fisher control valve assembly, illustrative only; parameters subject to the official data sheet

II. Six Leakage Class Definitions

ClassAllowable leakageSeat / test note
Class INo defined maximum (by agreement)Usually no leakage test required; no shutoff guarantee
Class II0.5% of rated capacityMetal-to-metal; water or air at 10-52 C, differential = lower of service dP or 50 psi
Class III0.1% of rated capacityMetal seat with improved seating accuracy
Class IV0.01% of rated capacityStandard metal-seated control valve; same test as Class II
Class V0.0005 mL/min per inch port diameter per psi differentialWater test at maximum service dP; lapped metal seat
Class VISpecified bubbles per minute by port sizeAir or nitrogen at low dP (typically 50 psig); soft seat, bubble-tight

The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; subject to the standard; no class values are assumed.

III. Test Methods and Conditions

ClassTest mediumTest differentialAcceptance method
II / III / IVClean water (or air)Lower of service dP and 50 psiCollect downstream leakage and measure volume per time
VWaterMaximum service dP (not above design rating)Normalized to mL/min per inch port per psi differential
VIAir or nitrogenTypically 50 psig (down to 10 psig for some valves)Count bubbles in a water column, corrected for port size
CautionDescription
Soft-seat temperature limitClass VI is a cold, low-pressure test and does not guarantee the same leakage at high temperature and pressure
Actuator thrustThe valve must be closed with rated actuator output; insufficient thrust invalidates the result
Online diagnosticsPressure-rise or acoustic methods can estimate in-service leakage; isolated volume and temperature must be known

The data in this article was obtained via web search. Source: ANSI/FCI 70-2 and IEC 60534-4 standard texts; online diagnostic methods are subject to instrument manufacturer manuals.

IV. Typical Fisher Trim Capabilities

Fisher product / trimTypical leakage class
easy-e ET / EZ (PTFE seat)Class V air test standard, Class VI optional
easy-e ET / ED (metal seat)Class IV standard, Class V / VI optional depending on trim
easy-e large ET/EWTClass V standard, Class IV optional (except Cavitrol III cage)
Vee-Ball V150 / V200 / V300Determined by seal construction (TCM / HD / Flow Ring) per ANSI/FCI 70-2
63EG-98HM (EPR / FFKM)Class VI shutoff per official manual

Source: Fisher D100017X012, D100023X012, D101554X012 and D102630X012 leakage tables; the final class is subject to the ordering code and factory test report.

V. Selection Guide and Common Models

Selection guide: Set the class by medium hazard and shutoff duty (toxic, flammable or clean gas service often needs Class VI), then check whether temperature and differential allow a soft seat. Metal seats generally achieve Class IV / V; soft seats can reach Class VI. Do not default to Class VI without weighing the temperature ceiling, service life and cost; where a class is not documented, refer to the official data sheet.

Common models: easy-e ET / EZ / ED, Vee-Ball V150 / V200 / V300 and 63EG-98HM; testing per ANSI/FCI 70-2 / IEC 60534-4.

If you need to verify the leakage class and factory test conditions of a control valve, please send us the valve type, seat material and service conditions. We can cross-check them against the Fisher official data sheet and the standard to avoid a wrong class selection.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.