The Fisher FIELDVUE DVC6200 is a digital valve controller with Hall-effect, linkage-less position feedback. Protocol variants include DVC6200H (HART), DVC6200F (FOUNDATION fieldbus) and DVC6200P (PROFIBUS PA), plus DVC6200 SIS with partial stroke testing. On HART versions the loop exposes valve position, setpoint, travel and diagnostic variables. This article covers the protocol variants, HART variables and parameter mapping, and clarifies that ODV diagnostics apply to the HART version only. I. Product Positioning
Source: Fisher FIELDVUE DVC6200 manual D103409X012 Table 1-2 and digital valve controller data sheet D104363X0CN. The data in this article was obtained via web search. Source: Emerson DVC6200 product page https://emerson.com/en/final-control/products/fisher-dvc6200.
II. Protocol Variants
Source: Fisher DVC6200 SIS manual D103557X012, DVC6200 manual D103409X012 and data sheet D104363X0CN; ODV level per D103605X012. III. HART Variables and Parameter Mapping
Source: Fisher D103409X012 Table 1-2 Specifications. Parameters are subject to the official manual and device configuration; no variable values are assumed. IV. Diagnostic Levels and ODV Limitation
The data in this article was obtained via web search. Source: Emerson DVC6200 product page https://emerson.com/en/final-control/products/fisher-dvc6200; level definitions are subject to Fisher D104363X0CN and D103605X012. V. Selection Guide and Common ModelsSelection guide: Choose H/F/P by the control system protocol, then the hazard approval and housing material (aluminum or stainless steel), then verify air supply, actuator action and feedback mounting, and finally select the diagnostic level. ODV applies only to the HART version DVC6200H; DVC6200F and DVC6200P do not offer ODV; SIS projects should select DVC6200 SIS. The exact variable list is subject to configuration and the official manual. Common models: DVC6200H (HART), DVC6200F (FF), DVC6200P (PROFIBUS PA), DVC6200 SIS; remote-mount versions DVC6205 + DVC6215; DVC6200S stainless-steel housing variant. If you need to verify the protocol variant of a DVC6200 or whether an ODV diagnostic level applies, please send us the ordering code and control system protocol. We can review the communication variables and diagnostic levels item by item against the Fisher official data sheet. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |