Home » Service & Support » Technical Documentation
Control Valve Selection - Technical Agreement & Data Sheet Preparation
Release time:2026-11-23 15:03:23 | Views:

The control valve selection technical agreement and data sheet are core procurement and engineering handover documents that determine whether the delivered valve meets the service. This article covers the clauses a technical agreement should include, the data sheet field list, sizing and verification items, applicable standards and acceptance points. The listed fields are general engineering practice; specific values are subject to the project specification, official data sheet and original standard.

I. Technical Agreement Scope

ClauseContent
Scope and boundariesSupply scope, quantity, interface boundaries, accompanying documents and spares
Service conditionsMedium, flow, pressure, temperature, differential pressure, density and state
Sizing parametersSize, Cv/Kv, flow characteristic, leakage class, materials
Applicable standardsASME B16.34, GB/T 12224, ANSI/FCI 70-2, IEC 60534, etc.
Accessories and communicationPositioner, actuator, handwheel, limit switch, communication protocol
Acceptance and documentsTest reports, material certificates, certification, nameplate and packaging

Source: technical agreement clauses are general engineering practice, referring to "Control Valve Selection Data Sheet" and "Common Pneumatic Control Valve Selection"; applicable standards subject to the original standard.

Control valve illustration
Control valve illustration; for illustration only, not the actual model; parameters subject to the official data sheet

II. Core Data Sheet Fields

FieldDescription
Tag / quantityUnique tag, quantity and installation location
Medium and stateLiquid/gas/steam, composition, density, viscosity
FlowMinimum / normal / maximum flow
PressureUpstream pressure (min/normal/max), downstream pressure, shutoff differential
TemperatureNormal / maximum / minimum temperature
Size and connectionNominal size, pressure class, flange standard, end form
MaterialsBody, trim, seat and packing materials
Trim and characteristicPlug form, flow characteristic (linear/equal percentage), Cv/Kv

The five selection elements can be summarized as size, material, pressure class, flow capacity (Cv) and temperature; the data sheet must give the complete service rather than a single design point so the manufacturer can perform sizing.

Source: data sheet fields refer to "Control Valve Selection Data Sheet" and "Common Pneumatic Control Valve Selection"; field values subject to the project specification.

III. Sizing and Verification Items

Verification itemKey point
Flow capacityCalculate required Cv from liquid/gas/steam formulas, select size from the manufacturer Cv table
Leakage classSpecify class per ANSI/FCI 70-2 or IEC 60534-4
Cavitation and flashingCheck pressure drop against allowable trim drop; anti-cavitation trim if needed
NoisePredict and control per standard for gas/steam services
Actuator thrustCalculate thrust and travel from stem unbalance force and differential pressure
RangeabilityCheck working opening and controllable range; avoid large valve at small opening

Source: verification items are general engineering practice; formulas and classes subject to ANSI/ISA-75.01.01, IEC 60534 and ANSI/FCI 70-2 original standards.

IV. Applicable Standards and Acceptance Documents

CategoryCommon standards / documents
Valve designASME B16.34, GB/T 12224
Flange connectionASME B16.5, GB/T 9113, EN 1092-1
Leakage testANSI/FCI 70-2, IEC 60534-4
Sizing calculationANSI/ISA-75.01.01, IEC 60534-2-1
Corrosion / sour serviceNACE MR0175 / ISO 15156 (per service)
Acceptance documentsMaterial certificate, pressure test report, leakage test report, certificate of conformity, certificates

Explosion-proof instruments also need ATEX/IECEx/CCC certification documents as required by the project; certificate status is subject to the official documents; where unavailable, write "please consult for confirmation".

Source: standard numbers refer to the "OKAWAY Control Valve Catalog" applicable standards list and web official standard information; subject to the original standard.

V. Preparation Points and Common Errors

Common errorImprovement
Only a single design flow givenGive three-point flow: minimum / normal / maximum
Only upstream pressure givenGive upstream/downstream and shutoff differential pressure
Leakage class not specifiedSpecify class per ANSI/FCI 70-2
Material compatibility ignoredSpecify body, trim and packing materials
PN and Class mixedUnify pressure class system and verify flange match

Selection guide: The path is "define supply scope, fill in complete service and data sheet, verify Cv/leakage/cavitation/noise/thrust, specify applicable standards and acceptance documents, then check accessories, communication and certification requirements". This is a general topic; recognized fields and verification items are given, and specific values are subject to the project specification, official data sheet and original standard.

Common models: Data sheets are usually filled by valve type (single-seat/cage/ball/butterfly), size, pressure class and material; specific model, Cv and certification are subject to the selected product's official data sheet.

If you are preparing a control valve data sheet or technical agreement and are unsure whether the service fields are complete or how to specify the leakage class and applicable standards, please share the service parameters and project requirements. We can review the data sheet clauses and verification items together.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.