Home » Service & Support » Technical Documentation
Yokogawa Temperature Transmitters - Technical Data & Selection
Release time:2026-11-23 12:03:36 | Views:

Yokogawa temperature transmitters are represented by the field-mount YTA610 and YTA710. They use a dual-compartment housing, accept single or dual sensor inputs, and offer 4-20 mA HART 7, BRAIN or FOUNDATION Fieldbus output. This article reviews positioning, accuracy, communication and selection points per the official hardware manual and website.

I. Product Positioning

ItemDescription
BrandYokogawa, independent brand; not to be mixed with Honeywell
Representative seriesYTA610 and YTA710 field-mount transmitters
Sensor inputsThermocouple, RTD, ohms, DC mV; single or dual input
Output and protocol4-20 mA HART 7 / BRAIN; FOUNDATION Fieldbus ITK 6
HousingDual-compartment field-mount housing
Functional safetyIEC 61508:2010 SIL 2 (applicable revisions and serial numbers per official note)
Key documentsHardware manual IM 01C50G01-01EN; official product pages

Source: Yokogawa YTA610/YTA710 hardware manual IM 01C50G01-01EN; official product page. Some data obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta610-temperature-transmitter/

Yokogawa temperature transmitter illustration
Transmitter illustration, not a Yokogawa product; for illustration only, not the actual model; parameters subject to the official data sheet

II. Key Technical Data

ParameterYTA710YTA610
A/D accuracy (Pt100)+/-0.1 C+/-0.14 C
D/A output accuracy+/-0.02% (4-20 mA analog)+/-0.03% (4-20 mA analog)
Linearized sensor types2021
Supply (HART/BRAIN)10.5-42 V DC10.5-42 V DC
Supply (Fieldbus)9-32 V DC9-32 V DC
Communication load resistance250-600 ohm250-600 ohm
Ambient temperature-40 to 85 C (with indicator -30 to 80 C)Per official general specification
Mounting2-inch pipe or flat panel2-inch pipe or flat panel
Weight (with indicator)Aluminium approx. 1.5 kg; SS approx. 3.3 kgPer official data sheet

Source: Yokogawa YTA610/YTA710 hardware manual IM 01C50G01-01EN; official product page. Some data obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta610-temperature-transmitter/

Values above were obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta710-temperature-transmitter/; subject to the model-specific general specification and nameplate.

III. Dual Input and Diagnostics

FeatureDescriptionNote
Sensor backupAutomatic switch-over on primary sensor failureRequires dual-input model
Differential / averageTwo sensors compute difference or averageFor redundancy or differential monitoring
Sensor matching CM1IEC 60751 and Callendar-Van Dusen correctionOption CM1 required
User temperature tableCustom thermocouple tableSupported on models such as YTA610
Local settingIndicator with buttons for on-site settingNo communicator required
DiagnosticsHardware fault, sensor break, differential alarmIntegrates with asset management

Source: Yokogawa YTA610/YTA710 hardware manual IM 01C50G01-01EN; official product page. Some data obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta610-temperature-transmitter/

IV. Intrinsic Safety Data and Approvals

CircuitParameter (/CU1 example)Note
Supply/output circuitUi=30 V, Ii=200 mA, Pi=1.0 W, Ci=22 nF, Li=0 mHFrom hardware manual approval section
Sensor circuitUo=6 V, Io=90 mA, Po=135 mW, Co=10 uF, Lo=3.9 mHFrom hardware manual approval section
Protection typesEx ia IS, Ex d flameproof; ATEX / IECEx / FM / CSASubject to nameplate and certificate
Associated apparatus matchingUo <= Ui, Io <= Ii, Po <= Pi, Co >= Ci+Ccable, Lo >= Li+LcableEntity concept per IEC 60079-25

Source: Yokogawa YTA610/YTA710 hardware manual IM 01C50G01-01EN; official product page. Some data obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta610-temperature-transmitter/

The electrical values above are manual examples; Ui/Ii/Pi/Ci/Li of the ordered model and Uo/Io/Po/Co/Lo of the barrier must be matched item by item. Where unavailable, write "please consult for confirmation". Ex ia IS and Ex d flameproof must not be mixed.

V. Selection Steps and Common Models

StepAction
1 ModelYTA710 (high accuracy) or YTA610 (general purpose)
2 ProtocolHART 7, BRAIN or FOUNDATION Fieldbus ITK 6
3 InputSingle or dual (backup/differential/average)
4 OptionsCM1 sensor matching, indicator, arrester, user temperature table
5 ApprovalsSelect Ex ia / Ex d and ATEX/IECEx/FM/CSA per area classification

Source: Yokogawa YTA610/YTA710 hardware manual IM 01C50G01-01EN; official product page. Some data obtained via web search, source: https://www.yokogawa.com/eu/solutions/products-and-services/measurement/field-instruments-products/temperature-transmitters/field-mount/yta610-temperature-transmitter/

Selection guide: The sequence is: choose YTA610 or YTA710, then protocol and input count, then sensor matching, indicator and Ex approval. The YTA710 offers higher accuracy than the YTA610; dual input, CM1 and user temperature tables must be specified in the order code. FieldMate (FDT/DTM) or a communicator is recommended for configuration; parameters are subject to the official general specification.

Common models: Common types: YTA610 (general purpose, HART 7 / FF) and YTA710 (high accuracy, HART 7 / BRAIN / FF), with options such as CM1 sensor matching, indicator and dual input.

If you are comparing the YTA610 and YTA710, or are unsure how to combine dual input, CM1 sensor matching and Ex codes, please share the sensor type, protocol and area classification. We can review the order code and IS parameters together and avoid mixing selection rules between Yokogawa and other brands.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.