Home » Service & Support » Technical Documentation
GO Switch - Intrinsically Safe Circuits & Explosion Protection Certifications
Release time:2026-11-23 09:02:36 | Views:

GO Switch is a non-contact position sensing / limit switch brand of TOPWORX (a company of Emerson Process Management). It uses permanent-magnet or ferrous-metal targets and sealed dry-contact outputs; switching itself needs no power and is immune to electrical noise and RFI. GO Switch offers Zone 0 intrinsic safety (Ex ia) and Zone 1 flameproof (Ex d) approvals for valve position feedback in hazardous areas. This article covers intrinsically safe loop design, approval codes, series capacities and selection points based on the official manual.

I. Product Positioning

ItemDescription
BrandGO Switch (a TOPWORX brand, part of Emerson Process Management)
PrincipleNon-contact magnetic sensing, sealed dry contact (SPDT/DPDT), no power needed for switching, immune to RFI/electrical noise
Environment-50 to +204 C (series/options dependent); submersible types to 7010 m
Main series10 series (long sensing range), 70 series (precision sensing, all stainless steel), 35 series (valve monitoring)
Typical useReplacing mechanical limit switches, built-in valve position feedback in switchboxes, cylinder end-of-stroke detection

Source: GO Switch official product manual (Chinese edition, 20 pages) and TopWorx official Discrete Valve Controller manual; subject to the latest official data sheet.

Limit switch position feedback device
Limit switch position feedback device illustration, not a GO Switch product; parameters subject to the official data sheet

II. Intrinsically Safe Loop Design

ItemRequirement
IS principleEx ia limits circuit energy (voltage/current) so no ignition occurs under normal or fault conditions
Associated apparatusA certified safety barrier or galvanic isolator in the safe area; field GO Switch must be an Ex ia approved model
Parameter matchingInterconnection must not exceed certificate parameters: field device Ui/Ii/Pi/Ci/Li less than or equal to associated apparatus Uo/Io/Po/Co/Lo (including cable capacitance and inductance)
WiringPer IEC 60079-14; IS and non-IS circuits separated, blue IS cable identification
Dry contact featureGO Switch sealed dry contact is a passive device suitable for IS loops; verify the Ex ia approval of the specific model

Ex ia intrinsic safety is NOT Ex d flameproof enclosure. IS limits energy and may permit live maintenance in the hazardous area (per site procedures); flameproof relies on an enclosure that withstands internal explosion. GO Switch offers both Ex ia (Zone 0) and Ex d (Zone 1) models and they must never be mixed. If a certificate cannot be found, state "unable to confirm, please verify with the manufacturer".

Source: GO Switch official product manual approval table; IS loop per IEC 60079-11 and IEC 60079-14; approvals subject to nameplate and original certificates.

III. Explosion-Protection Approval Codes (70 Series Example)

Approval codeApproval content (manual extract)
FZone 0, Ex ia IIC T6 Ga (intrinsic safety)
GZone 0, Ex ia IIC T4 Ga
HZone 0, Ex ia IIC T3 Ga
9Zone 1, ATEX/IECEx Ex d IIC, Ex tD A21, IP66 T85 C (flameproof)
NNEPSI Ex d IIC T3/T6 (China)
3 / 4 / 6UL Class I Div 1&2 / CSA Class I Div 1 / Div 2

Approval codes are written in the "approvals" position of the ordering code; available codes differ by series. Ex ia (F/G/H) and Ex d (9/N) are different protection concepts, and T6/T4/T3 are different temperature classes. Selection must be checked against the area classification and medium properties; do not imply that only a certain model holds a certain certificate.

Source: GO Switch official product manual, 70-series ordering code "approvals" position table; approvals subject to nameplate and original certificates.

IV. Series and Switching Capacity

SeriesFeaturesSwitching capacity
10 series (11/21/31/81)Long sensing range 6-10 mm, replacing mechanical limit switchesSPDT max 10A/120VAC
70 series (71-77/7G/7H etc.)Precision sensing 1-2.5 mm, all stainless steel, up to 10000 psi, global hazardous-area approvalsSealed dry contact, per contact form
35 seriesValve monitoring, built into TopWorx switchboxesSPDT/DPDT 4A/120VAC, 3A/24VDC
Special typesStroke-To-GO, submersible, HiTemp (204 C), 7A pneumatic valve, nuclear gradePer model

Switching capacity (the load the contact can switch) and Ex approval are two independent dimensions: a 4A/120VAC dry contact may be an Ex ia model or a non-approved model, so capacity and certificate must be verified separately.

Source: GO Switch official product manual series parameters and quick selection guide; capacity subject to the official data sheet.

V. Application and Installation Points

ItemKey points
TargetPermanent-magnet or ferrous-metal target; target magnet available to extend sensing range
MountingVerify sensing distance and mounting gap (1-2.5 mm or 6-10 mm by series); avoid adjacent metal interference
WiringAC/DC and NO/NC both connectable, series or parallel; IS loops matched to barriers per certificate parameters
EnvironmentAll-metal housing plus potting, resistant to vibration, moisture and contamination; extreme temperature and high pressure by series options
MaintenanceSealed dry contact is maintenance-free; live cover opening and flameproof-enclosure rules follow the corresponding approval

Source: GO Switch official product manual principles and applications chapters; mounting gaps and wiring subject to the official manual.

VI. Selection Guide and Common Models

Selection guide: First select the series by application: mechanical limit switch replacement and long sensing range lead to the 10 series; precision, corrosive, high-pressure and hazardous areas lead to the 70 series; built-in valve switchbox feedback leads to the 35 series. Then select the protection concept by area classification and medium: Zone 0 intrinsic safety uses Ex ia (codes F/G/H, T6/T4/T3), Zone 1 flameproof uses Ex d (codes 9/N); then verify switching capacity (10A/120VAC or 4A/120VAC, 3A/24VDC), target, sensing distance and electrical interface. IS loops require a certified barrier with matched parameters; Ex ia is NOT Ex d and they must never be mixed; if a certificate cannot be found, state "unable to confirm, please verify with the manufacturer".

Common models: 35 SPDT/DPDT (valve monitoring, 4A/120VAC, 3A/24VDC); 70 series such as 71/73/75/77 and 7G/7H (precision sensing, optional F/G/H IS or 9/N flameproof); 10 series 11/21/31/81 (long sensing range). Exact ordering codes follow the official selection manual and nameplate.

If you are selecting GO Switch position feedback for a hazardous-area valve, or are unsure how to match intrinsically safe loop parameters with approval codes, please send us the site area classification, medium and barrier model. We can review the approvals, capacity and wiring against the official manual.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.