ValveLink is the configuration and diagnostic software supplied by Fisher for FIELDVUE digital valve controllers. It connects to DVC2000 / DVC6200 through a HART communicator to perform parameter setting, travel calibration, performance diagnostics and partial stroke testing. This article covers the field workflow of connect, configure, calibrate, diagnose and report, with the diagnostic level required at each step. I. Tools and Scope
Source: Fisher Bulletin 62.1 "Digital Valve Controller" D104363X0CN; DVC6200 instruction manual D103409X012 (Table 1-2 Specifications); DVC6200 SIS manual D103557X012; diagnostic levels D103605X012.
II. Connection and Communication Setup
Source: Fisher Bulletin 62.1 "Digital Valve Controller" D104363X0CN; DVC6200 instruction manual D103409X012 (Table 1-2 Specifications); DVC6200 SIS manual D103557X012; diagnostic levels D103605X012. III. Configuration and Calibration Workflow
Source: Fisher Bulletin 62.1 "Digital Valve Controller" D104363X0CN; DVC6200 instruction manual D103409X012 (Table 1-2 Specifications); DVC6200 SIS manual D103557X012; diagnostic levels D103605X012. IV. Offline Diagnostics and Partial Stroke Testing
Source: Fisher Bulletin 62.1 "Digital Valve Controller" D104363X0CN; DVC6200 instruction manual D103409X012 (Table 1-2 Specifications); DVC6200 SIS manual D103557X012; diagnostic levels D103605X012. Red lines: ODV is HART only and is not offered on DVC6200F or DVC6200P; PS applies to DVC6200F only; DVC6200P does not support AD / PD and therefore cannot provide ValveLink offline and online diagnostics. If the customer has no HART acquisition or asset management facility, diagnostic data will not be used routinely, so this should be clarified at selection stage. V. Common Faults and Actions
Source: Fisher Bulletin 62.1 "Digital Valve Controller" D104363X0CN; DVC6200 instruction manual D103409X012 (Table 1-2 Specifications); DVC6200 SIS manual D103557X012; diagnostic levels D103605X012. VI. Selection Guide and Common ModelsThe ValveLink workflow runs from mechanics and pneumatics, through communication setup, parameter configuration, calibration, diagnostic testing, to reporting and archiving. Every step depends on the correct diagnostic level and site software: AD for offline diagnostics, PD for online, and ODV (HART only) or SIS for PST. Do not treat diagnostic capability as equivalent to a SIL rating; they are different dimensions. Selection guide: Selection order: device and protocol, then diagnostic level, then software and host. ValveLink is a tool rather than a model; whether a diagnostic function is usable depends on segment 9 of the device order code, not merely on software installation. Common models: DVC2000 + HART communicator (basic configuration); DVC6200H + AD / PD / ODV (full ValveLink diagnostics and PST); DVC6200F + FD / AD / PD / PS (FF diagnostics); DVC6200-SIS (PST standard). If you cannot connect the communicator, initialization fails, or diagnostic functions are unavailable in the field, please share the device order code and symptoms. We can review the workflow against the diagnostic level, air supply conditions and software version. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |