The Siemens SIPART PS2 is a smart electropneumatic valve positioner for linear and rotary, single-acting and double-acting pneumatic actuators. It supports 4 to 20 mA, HART, PROFIBUS PA and FOUNDATION Fieldbus with ingress protection IP66 / NEMA 4X. Its order code uses the 6DR5 prefix and splits into two independent tables for non-flameproof and flameproof housings whose options are not interchangeable. This article decodes the overall structure, housing codes, -Z options, function modules and accessories, plus selection red lines, based on the official Siemens selection manual. I. Product Positioning and Two Selection Branches
The key red line: the two code tables have non-interchangeable options and the same letter can mean different things. For example, explosion-protection digit E means intrinsic safety Ex i in the non-flameproof table but flameproof Ex d plus dust Ex t in the flameproof table. The branch must be determined by the housing digit before digit-by-digit configuration. Source: Siemens SIPART PS2 official selection-rules manual and technical data compilation. Current production status and codes are subject to the manufacturer's latest data / ordering tool.
II. Overall Order-Code Structure
Before selecting, gather: actuator type and action, travel or rotation, air-chamber volume, control signal and protocol, hazardous-area classification and protection form, housing material and corrosion environment, cable and air threads, power / air-loss action, whether SIL2 is required, limit signals and position feedback, pressure-gauge material, advanced diagnostics and Bluetooth / low-temperature / natural-gas options, air medium and pressure, mounting bracket and certificate requirements. Source: Siemens SIPART PS2 selection-rules manual (order-code structure and information checklist). Exact digits and options are subject to the official ordering manual / tool. III. Housing Codes and Materials
When the customer does not specify housing material, the sample's business practice defaults to code 0 (plastic top plus aluminium base); use 3 for Ex e / Ex t and 2 for strong corrosion / offshore / chlorine. Flameproof housings (5 / 6) reduce air volume by about 20%, which must be included in actuator sizing. Source: Siemens SIPART PS2 selection-rules manual (quick guide by housing material). Weights and materials are subject to the official data sheet. IV. -Z Option Codes
Some combinations are mutually exclusive: mechanical limit switches MLS are not for natural-gas service (conflicts with -Z K50); the VDI/VDE 3847 interface -Z K20 is not for flameproof housings; low temperature -40 C (-Z M40) cannot be combined with double-acting lock-up (this exclusion was confirmed by a Siemens office but is not listed directly in the sample and must be finally confirmed with Siemens). Source: Siemens SIPART PS2 selection-rules manual (-Z option table and constraints table). Exclusions and codes are subject to the official manual / manufacturer confirmation. V. Function Modules and Accessories
The separate NCS sensor uses order number 6DR4004-·N·· with cable lengths N=6 m, P=20 m, R=40 m and actuator types 2 for linear travel up to 14 mm, 3 for linear 14 to 130 mm and 4 for rotary; it is not for flameproof applications. The three extension digits are shared fields, so L1A for internal NCS and R** for a pressure gauge cannot appear together. Source: Siemens SIPART PS2 selection-rules manual (common accessories and order-number tables). Order numbers are subject to the official ordering manual. VI. Selection Guide and Common ConfigurationsSelection guide: The sequence is "branch by housing digit (0/2/3 non-flameproof table or 5/6 flameproof table), define signal type, define single / double acting, define housing material, define explosion-protection code, define cable and air threads, select -Z options, then verify accessories and extension digits". Red lines: 1. the two code tables must not be mixed because the same letter has different meanings; 2. Ex ia intrinsic safety is not Ex d flameproof enclosure and must be looked up in the correct branch; 3. SIL2 applies only to single-acting 6DR5.1.*; 4. flameproof housings have about 20% less air volume and require actuator rechecking; 5. exclusions are subject to the official manual / final manufacturer confirmation, and order codes are never invented. Common configurations: Indoor non-hazardous service commonly uses 6DR5..0 (plastic top plus aluminium base); strong corrosion or offshore uses 6DR5..2 stainless; Zone 1 flameproof uses 6DR5..5 or 6DR5..6. Wide-range diagnostics use P01 / P02, SIL2 uses -Z C20 and Bluetooth commissioning uses -Z F50. Signal versions follow the DCS protocol: 4 to 20 mA HART, PA or FF. If you have a 6DR5 order code but are unsure which code table it belongs to, or want to confirm a positioner's housing, explosion protection and diagnostic options, feel free to send us the complete code and site environment. We can check it digit by digit against the official manual and flag any items needing manufacturer confirmation. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |