Home » Service & Support » Technical Documentation
Yokogawa Differential Pressure Transmitters - Technical Data & Selection
Release time:2026-11-22 09:38:23 | Views:

Yokogawa Electric DPharp digital-sensor differential pressure transmitters fall mainly into the EJA-E and EJX-A series: the EJA110E is a standard traditional-mount DP transmitter and the EJX110A is the high-performance version, both using a silicon resonant sensor that measures differential pressure, static pressure and sensor temperature simultaneously. This article covers performance data, capsule spans, wetted-material codes, model code structure and a selection checklist. All figures come from official samples and the official website, with sources noted item by item; the official manual / nameplate governs.

I. Brand and Product Positioning

ItemDescription
BrandYokogawa Electric (independent brand; do not confuse with any legacy or translated name)
SensorDPharp digital silicon resonant sensor measuring DP, static pressure SP and sensor temperature at once
Main seriesEJA-E (standard, representative model EJA110E); EJX-A (high performance, representative model EJX110A)
Typical applicationsLiquid, gas and steam flow, level, density and pressure measurement; used with manifolds or diaphragm seal systems
Communication4 to 20 mA with BRAIN / HART, plus FOUNDATION Fieldbus and PROFIBUS PA versions
Process connectionIEC 61518 compliant 3-valve / 5-valve manifold interface, universal mounting

Always select by the complete nameplate code: within one base model such as EJA110E the output signal, capsule, wetted materials, electrical connection, indicator and hazardous-area option can be completely different. The words "EJA110E" alone are not enough to identify a spare or replacement.

Data obtained via web search, source: https://www.yokogawa.com/solutions/products-and-services/measurement/field-instruments-products/pressure-transmitters/differential-pressure/eja110e/; https://mip.cys.com.cn/wp-content/uploads/library/gs/EJX110A.pdf. Subject to the official manual / nameplate.

Differential / pressure transmitter appearance
Differential / pressure transmitter appearance reference, not a Yokogawa unit and not the actual model; parameters subject to official samples

II. EJA110E and EJX110A Performance Comparison

ParameterEJA110EEJX110A
Reference accuracy (primary DP)+/-0.055% of span (optional +/-0.04%)High-performance type, per GS 01C25B01-01EN (typically +/-0.055%, high-accuracy option available)
Secondary variable (static pressure)+/-0.5%, response 360 msStatic pressure measured and shown on local indicator or remotely via BRAIN / HART
Response timePrimary variable 90 msUpdate period: DP 45 ms, static pressure 360 ms
Long-term stabilityPrimary variable +/-0.1% URL per 10 yearsHigh-stability design of the same family; see the data sheet
Overpressure effectPrimary variable +/-0.03% URLOverpressure tolerant design, returning within specification without recalibration
RangeabilityPrimary variable 100:1Set by capsule span range, see the official data sheet
Functional safetyEJA-E series Exida / TUV certified SIL 2 / SIL3Except FF and PA types: SIL 2 for single transmitter, SIL 3 capability for dual use
Advanced diagnostics40 self-checks, back-check technology, 10-segment signal characterizerImpulse-line blockage detection, heat-trace monitoring (depending on output signal code)

Different output signal codes (for example FF or PA) affect whether certain diagnostics and indicator functions are available. High-accuracy options such as /HAC change both accuracy and capsule ranges, so the complete order code must be checked.

Data obtained via web search, source: https://www.yokogawa.com/us/solutions/products-and-services/measurement/field-instruments-products/pressure-transmitters/differential-pressure/eja110e/; https://web-material3.yokogawa.com/GS01C25B01-01EN.pdf; https://www.onlysft.com/uploads/32788/files/pressure-transmitters/YOKOGAWA%20%20EJA110E%20Differential%20Pressure%20Transmitter.pdf. Subject to official manuals GS 01C31B01-01EN / GS 01C25B01-01EN.

III. Measurement Capsules (Span Codes)

CodeMeasurement range (kPa, excerpt)Conversion exampleNotes
F*0.1 to 5 kPa0.4 to 20 inH2ODraft range; applicable only with wetted material code S
L*0.1 to 10 kPa1 to 100 mmH2O (/D4)Low differential pressure
M0.5 to 100 kPa2 to 400 inH2OCommon mid range; accuracy given in segments for X within span and X above span
H2.5 to 500 kPa10 to 2000 inH2OHigh differential pressure
V0.07 to 14 MPa10 to 2000 psiHigh static pressure / large DP span

The capsule sets configurable lower and upper range values (LRV / URV); final range must be configured and verified for the actual service including static line pressure. Check DP span and line static pressure together: a transmitter with a suitable DP span but insufficient static-pressure rating is equally unusable.

Data obtained via web search, source: https://mip.cys.com.cn/wp-content/uploads/library/gs/EJX110A.pdf; https://www.onlysft.com/uploads/32788/files/pressure-transmitters/YOKOGAWA%20%20EJA110E%20Differential%20Pressure%20Transmitter.pdf. Subject to official manuals GS 01C25B01-01EN / GS 01C31B01-01EN originals.

IV. Wetted Material Codes

CodeCover flange / process connectorCapsule / diaphragmFeature
SASTM CF-8MHastelloy C-276 diaphragm, others F316L / 316L SSTMost common standard configuration
LASTM CF-3MHastelloy C-276 diaphragm, others F316L / 316L SSTLow-carbon stainless flange
HASTM CF-8MHastelloy C-276Hastelloy capsule
MASTM CF-8MMonelSuited to hydrofluoric acid, seawater and similar services
TASTM CF-8MTantalumSeverely corrosive service
A / DHastelloy C-276 equivalentHastelloy C-276 / tantalumCodes marked # conform to NACE MR0175 / ISO 15156 recommendations
BMonel equivalentMonelCodes marked # conform to NACE recommendations

Wetted materials must be checked against fluid corrosiveness. The official sample explicitly warns that with strongly corrosive media such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite and high-temperature steam at or above 150 C, incorrect materials can damage the diaphragm, leak fill fluid and contaminate the process. Codes marked # comply with NACE MR0175 / ISO 15156 and also NACE MR0103, subject to the latest standards.

Data obtained via web search, source: https://web-material3.yokogawa.com/GS01C31B01-01EN_007.pdf; https://web-material3.yokogawa.com/GS01C25B01-01EN_030.pdf. Subject to the wetted-materials table in the official manual.

V. Model Code and Option Structure

FieldOptions (excerpt)Notes
Base modelEJA110E / EJX110A (DP); related 130E / 130A high-static DP modelsDetermine base model from measurement function first
Output signal4 to 20 mA with BRAIN / HART; FF; PROFIBUS PAMust match the existing DCS and asset-management system
CapsuleF / L / M / H / VSee span ranges in Section III
Wetted materialsS / L / H / M / T / A / D / B / W (some models)See Section IV; confirm strongly corrosive media with the manufacturer
Electrical connection0: G1/2 single; 2: 1/2 NPT dual; 4: M20 dual; 5 / 7 / 9: dual with blind plug; A / C / D: SUS316 blind plugDetermines cable gland and installation space
IndicatorD: digital indicator; E: digital indicator with range-setting switch; N: noneLocal parameter setting requires an indicator version
Mounting bracketB / D (304 SST), J / K / M (316 SST), N (none)Select for horizontal / vertical piping or bottom process connection

For replacement or expansion, read the complete nameplate code and confirm static pressure, capsule, wetted materials, communication protocol and electrical connection. Instruments with the same base model but different suffixes may be mechanically and electrically incompatible, so ordering by the generic words "DP transmitter" is not sufficient.

Data obtained via web search, source: https://web-material3.yokogawa.com/GS01C25B01-01EN_030.pdf; https://tomarok.com/yokogawa-instrumentation/yokogawa-pressure-transmitter-model-code/. Exact code sequence and available options are subject to the official general specification / nameplate.

VI. Selection Guide and Common Configurations

Selection guide: The sequence is "define measurement function and base model, define output protocol, define capsule span and static pressure, define wetted materials, define electrical connection, indicator and bracket, verify hazardous-area approvals, then recheck the complete nameplate code". Red lines: 1. Yokogawa Electric is an independent brand and must not be written under any legacy or mixed name; 2. the same base model with different suffixes can differ greatly, so order by the complete code; 3. wetted materials for strongly corrosive media and steam above 150 C must be confirmed with the manufacturer; 4. FF / PA types differ from HART types in functional safety and some diagnostics; 5. all figures are subject to the official manual / nameplate (data obtained via web search, source: official manuals GS 01C31B01-01EN and GS 01C25B01-01EN, and the Yokogawa website).

Common configurations: General DP flow / level service commonly uses an EJA110E with M or H capsule, S wetted material, 4 to 20 mA HART, indicator and a 2-inch pipe-mount bracket. High accuracy and advanced diagnostics use the EJX110A. High static pressure uses 130E / 130A or the V capsule. Corrosive service selects H / M / T / A / D / B wetted materials by fluid. Replacement and spares require the full model code and configuration data.

If you only have a nameplate photo of an old transmitter, or need to confirm whether a DP transmitter's capsule, wetted material and communication version can be replaced, feel free to share the nameplate data and service conditions. We can check the model code and static-pressure condition together against the official specification.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.