A control valve leakage class defines how much fluid may pass through the seat when the valve is fully closed. It is the data-sheet clause most often overlooked yet directly affects safety and factory acceptance. The most widely referenced standard is ANSI/FCI 70-2 (internationally mirrored by IEC 60534-4), which defines six seat leakage classes from Class I to Class VI. This article explains each class limit, test procedure, allowable leakage tables and service-based selection; figures are subject to the standard original and official manufacturer samples.

I. Subject Positioning and Standards System

ItemDescription
SubjectControl valve seat leakage classes (ANSI/FCI 70-2, Class I to VI)
Corresponding standardANSI/FCI 70-2; international projects often cite IEC 60534-4; terminology and class logic are consistent
Easily confused standardANSI/FCI 70-2 applies to control valves; FCI 70-3 applies to regulators with Class I to VIII and must not be interchanged
Defined quantitySeat internal leakage with the valve closed, not stem-packing fugitive emissions (covered separately by ISO 15848-1)
Nature of testFactory acceptance test on a new, clean valve at room temperature; not a guarantee after long service, thermal cycling or erosion
Data basisClasses and limits are recognized standard content; figures are subject to the ANSI/FCI 70-2 original / official samples

Data sheets must state the standard number, class, test medium and test differential pressure. Writing only "zero leakage" or "bubble-tight" without standard and conditions is a typical invalid description: allowable leakage differs by three orders of magnitude between classes.

Standards system references FCI official material (data obtained via web search, source: https://www.fluidcontrolsinstitute.org/assets/downloads/SeatLeakageOverview.ppsx). Subject to the ANSI/FCI 70-2 original / official samples.

Control valve body appearance
Control valve body appearance reference, not the actual model; parameters subject to official samples

II. Class I to VI Allowable Leakage

ClassMaximum allowable leakageTest procedureTypical seat construction
Class INo specified test requirement (agreed between manufacturer and user)NoneMetal-to-metal, general purpose, no shutoff guarantee
Class II0.5% of rated full-open Cv (rated capacity)AMetal seat, unbalanced plug, general industrial service
Class III0.1% of rated capacityAMetal seat with better lapped fit
Class IV0.01% of rated capacityAPrecision-lapped metal seat, most common industrial baseline
Class V5 x 10^-4 mL of water per minute per inch of seat diameter per psi differential; equivalent to 5 x 10^-12 m3/s per mm per barB; air method B1 also definedMetal seat, precision lapped, high seat load for critical high-pressure or hazardous fluids
Class VITabulated by seat diameter, measured in mL/min of air or nitrogen or bubbles/min (see Section III)CSoft seat (PTFE, PEEK, elastomer insert), "bubble-tight" shutoff

Classes II to IV are expressed as a percentage of rated capacity, so for the same class a larger valve permits a larger absolute leakage. Classes V and VI are instead based on seat diameter and differential pressure or diameter alone, independent of Cv. Class V is far tighter than IV for metal seats and requires higher seat load and greater actuator thrust.

Limits per ANSI/FCI 70-2 Table 1 (data obtained via web search, source: https://www.fluidcontrolsinstitute.org/assets/downloads/SeatLeakageOverview.ppsx; https://www.changshuigroup.com/news/industry-news/control-valve-leakage-classes-how-to-read-test-and-select.html). Subject to the standard original / official samples.

III. Class VI Allowable Leakage by Seat Diameter

Nominal seat diameter mm (in)Maximum leakage mL/min (air or nitrogen)Bubbles per minute
less than 25 (less than 1)0.151
40 (1.5)0.302
50 (2)0.453
65 (2.5)0.604
80 (3)0.906
100 (4)1.7011
150 (6)4.0027
200 (8)6.7545

"Bubble-tight" for Class VI is a quantified result under test conditions, not absolute zero leakage or a permanent guarantee. Larger sizes continue per the standard table (250 mm is 11.1 mL/min, 300 mm is 16.0 mL/min, etc.). Selection should quote the official table directly rather than estimating from memory.

Figures per ANSI/FCI 70-2 Table 2 (data obtained via web search, source: https://www.fluidcontrolsinstitute.org/assets/downloads/SeatLeakageOverview.ppsx). Subject to the standard original / official samples.

IV. Test Procedures and Conditions

ProcedureTest medium and pressureApplicable classesNotes
AAir, nitrogen or water, 45 to 60 psig (approx. 3.5 bar)Class II, III, IVMeasured as a percentage of rated capacity
BWater, maximum service differential pressure (or as agreed)Class VMeasured per inch of seat diameter per psi differential
B1Air or nitrogen, 50 psigClass V (air method)Approx. 4.7 standard mL/min per inch of seat diameter
CAir or nitrogen, the lesser of maximum rated differential pressure and 50 psigClass VIMeasured in mL/min or bubbles per the Section III table
TemperatureRoom temperature (approx. 50 to 125 F)AllSeparate provisions apply to temperature regulators

Specifying different test procedures for the same valve can change the acceptance result substantially. In particular, requiring Class V to be tested with water at full operating differential pressure significantly increases required actuator thrust. The test medium, pressure and class should all be written into the specification to avoid FAT disputes.

Procedures per ANSI/FCI 70-2 Section 5 (data obtained via web search, source: https://www.fluidcontrolsinstitute.org/assets/downloads/SeatLeakageOverview.ppsx). Subject to the standard original / official samples.

V. Typical Product Capability and Service Selection

Product / service exampleAchievable class (excerpt)Notes
Fisher Finetrol FC / FG rotary eccentric plug valveSoft seat Class VI; metal seat Class IV (Class V optional)Soft and metal seats give different classes and must not be interchanged
Fisher CAV4 with Cavitrol IV high-pressure-drop valvePiston-ring construction Class IV; angle body Class VI; globe body Class V; TSO trim tested to Class VClasses differ by construction within one platform; verify the specific configuration
Fisher NotchFlo DST multistage anti-cavitation valveClass V (less than 5 x 10^-12 m3/s per bar per mm)Multistage trim for dirty, cavitating services
Cooling water, general utilitiesClass III or IVLeakage is not a safety or product-loss issue
Steam, condensate, boiler feedwaterClass IV (Class V for high-pressure bypass)Continuous leakage wastes energy and erodes the seat
Flammable, toxic or high-value fluidsAt least Class IV; Class V or VI for critical isolationBellows seal may be added with a separate fugitive-emission requirement

Red lines: 1. Class VI soft seats are temperature limited; PTFE-based seats typically reach approx. 200 to 230 C and PEEK approx. 260 to 300 C depending on load, so do not specify Class VI casually for hot service; 2. a leakage class is a factory test result, not a durability guarantee; 3. stem-packing external leakage is a fugitive-emission matter covered separately by ISO 15848-1; 4. a higher class requires greater actuator thrust, which must be verified.

Product data from official samples / manuals (Fisher Finetrol FC/FG data sheet, CAV4 installation manual 11744502, NotchFlo DST manual D103036X012). Service guidance references public technical material (data obtained via web search, source: https://www.kosavalve.com/NEWS_CENTER/control-valve-leakage-class-ansi-fci-70-2.html). Subject to the standard original / official samples.

VI. Selection Guide and Common Configurations

Selection guide: The sequence is "set the class range by fluid hazard, confirm achievability by temperature and seat construction, then verify actuator thrust and test conditions". General metal-seat control valves default to Class IV; Class V applies for high pressure, hazardous or high-value fluids; Class VI applies when bubble-tight shutoff is required and temperature is within soft-seat limits. The specification should state ANSI/FCI 70-2 (IEC 60534-4), class, test medium and test differential pressure; where data is unavailable or uncertain, write "please consult for confirmation" and rely on the standard original / official samples.

Common configurations: General control valves are typically metal-seat Class IV; steam and high-pressure bypass use Class IV / V; isolation and vacuum service use soft-seat Class VI; fugitive-emission requirements add bellows seals and low-emission packing. Different seat / trim combinations in one valve type give different classes, so the specific ordered configuration governs.

If a specification says "zero leakage" or "bubble-tight" without a verifiable class, or a valve fails its FAT seat leakage test, please share the medium, temperature, differential pressure and valve type. We can check the class, test conditions and achievability together.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.