Home » Service & Support » Technical Documentation
Rotork / AUMA Electric Actuators - Technical Data & Selection
Release time:2026-11-22 09:38:23 | Views:

An electric actuator converts electrical energy into linear thrust or rotary torque for a valve and is suitable where there is no instrument air, where precise travel control is needed, or where fieldbus integration is required. Rotork and AUMA are two independent electric actuator brands. This article compiles publicly available official data for their multi-turn and part-turn products and gives the selection basis for duty, torque and speed. All data below comes from online searches, with sources noted in each section.

I. Product Positioning

ItemRotorkAUMA
BrandRotork plc, UK, independent brandAUMA Riester GmbH & Co. KG, Germany, independent brand
Representative seriesIQ3 (intelligent multi-turn / part-turn), IQT3 (part-turn)SA (multi-turn, open-close / positioning), SAR (modulating), SQ (part-turn)
Output formDirect torque multi-turn; 90 degree part-turnMulti-turn; gearboxes for part-turn output
Typical loadGate and globe valves (multi-turn); ball and butterfly valves (part-turn)Gate and globe valves; GST/GK gearboxes for 90 degree valves
SourceRotork IQ3 Pro brochure PUB002-407; IQ3 catalogue PUB002-038AUMA official SA product page (auma.com)

The two brands have different strengths: the Rotork IQ3 emphasizes non-intrusive commissioning, absolute encoder position retention and a Bluetooth setting tool, while the AUMA SA emphasizes modularity, a wide torque range and diagnostics/fieldbus integration through AC actuator controls. Both must be sized to the actual valve torque demand, not by brand alone.

This data comes from online searches, sources: https://www.rotork.com/uploads/documents-versions/42883/1/pub002-038-00_0618.pdf ; https://media.rotork.com/api/public/content/pub002-407-000526iq3prorangeflyer2-page-pdf-sjyrvee8sto4j92j7czy.pdf ; https://www.auma.com/en_GB/products/product-p35477 . Rotork and AUMA are independent brands; data is cited only from each brand's own official site.

Electric / pneumatic actuator appearance reference
Electric / pneumatic actuator appearance reference, not the actual model shown; parameters subject to official catalogue

II. Rotork IQ3 / IQT3 Technical Data

ModelSupply / dutyDirect torque outputKey feature
IQ3 Pro3-phase, S2/S3 (class A/B), up to 60 starts/hr14-3000 NmOil-bath lubrication; IP66/IP68 (7 m/72 h); non-intrusive setup
IQ3S Pro1-phase10-450 NmLow-torque single-phase version
IQ3D ProDC 24/48/110 V11-305 NmDC powered version
IQ3H Pro3-phase high speed27-397 Nm, speed up to 259 rpmHigh speed, self-locking
IQ3M / IQ3ML Pro3-phase modulating, S4 / class C11-544 Nm; ML thrust up to 43 kNUp to 1200 starts/hr
IQT3 Pro (part-turn)3-phase / 1-phase / DC125-3000 Nm90 degree output, isolation or regulation

This data comes from online searches, sources: https://media.rotork.com/api/public/content/pub002-407-000526iq3prorangeflyer2-page-pdf-sjyrvee8sto4j92j7czy.pdf (IQ3 Pro Range Flyer) and https://www.rotork.com/uploads/documents-versions/42883/1/pub002-038-00_0618.pdf (IQ Range IQ3 catalogue). The IQ3 uses a contactless absolute encoder capable of measuring up to 8,000 output turns and retains valve position even without power.

This data comes from online searches, sources: Rotork IQ3 Pro Range Flyer (PUB002-407) and IQ3 data sheet (PUB002-038), URLs above. Specific order configurations and certificates are subject to Rotork official manuals.

III. AUMA SA / SAR Technical Data

ItemSA multi-turn (open-close / positioning)SAR multi-turn (modulating)
Torque range10-32000 NmBy size, covering modulating duty of the same platform
DutyClass A/B, short-time S2 - 15 min (S2 - 30 min by special design)Class C, S4 - 25% (S4 - 50% and S5 - 25% also available)
Output speed4-180 rpmBy size
Protection / temperatureIP68; -30 to +70 C; KS corrosion protectionSame platform
Motor / operation3-phase / 1-phase AC and DC motors; handwheelSame platform
Functional safetyUp to SIL 2 in selected configurations, up to SIL 3 with AC 01.2 SIL controlsSame platform

This data comes from online searches, source: https://www.auma.com/en_GB/products/product-p35477 (AUMA official SA product page). The AUMA SAEx explosion-protected version has a torque range of 10-16000 Nm, IP68, ATEX Ex db eb IIC / Ex db IIC and Ex tb IIIC; the exact Ex marking is subject to the AUMA product page and certificates.

This data comes from online searches, sources: AUMA official SA product page https://www.auma.com/en_GB/products/product-p35477 and SAEx product page. Rotork and AUMA data are taken only from each brand's own official site and are not cross-referenced.

IV. Selection Calculation and Key Points

ItemFormula / basisNote
Torque demandT_req >= T_valve x SF (safety factor typically 1.3-2.0 by service and valve type)Valve torque must come from the valve manufacturer, including shutoff differential and seat friction
Linear thrustF_req >= T_stem / r, or select directly by required stem thrustMulti-turn actuators convert rotation to thrust via the stem nut
Stroke timet = required turns / output speedCheck against the process full-stroke time
DutyOn-off S2/S3; modulating S4/S5 by starts per hourModulating duty has far more starts than on-off duty
Max stem torqueActuator output must not exceed MASTAvoid damaging the stem and drivetrain
Interface and fieldbusISO 5211 / DIN connection; Modbus TCP, EtherNet/IP, PROFINET, etc.Check against site fieldbus and mechanical interface

Selection sequence: (1) define the valve type and full-stroke torque curve; (2) decide multi-turn or 90 degree part-turn (large 90 degree valves often need a worm or spur gearbox); (3) select the torque rating by T_req and SF; (4) select on-off or modulating by duty; (5) set electrical configuration by site supply and fieldbus; (6) set Ex form and certificate by area classification; (7) verify mechanical interface, handwheel and torque limit setting.

Torque safety factors, stroke time and duty are general engineering bases; Rotork/AUMA parameters and certificates are subject to their own official manuals. No values are invented.

V. Selection Guide and Common Models

Selection guide: Follow "define valve torque, define rotary form, define torque rating, define duty, define electrical and fieldbus, define Ex and interfaces". Core red lines: (1) Rotork and AUMA are independent brands and data must be cited only from each own official site; (2) torque must be based on the valve manufacturer's actual duty value plus a safety factor and must not exceed MAST; (3) distinguish on-off duty S2/S3 from modulating S4/S5, which have different start rates; (4) Ex forms and SIL approvals are subject to official certificates; if unavailable write "confirm by inquiry".

Common models: Rotork IQ3 Pro (multi-turn, 14-3000 Nm), IQT3 Pro (part-turn, 125-3000 Nm), IQ3S/IQ3D/IQ3M variants; AUMA SA (multi-turn, 10-32000 Nm), SAR (modulating), SQ (part-turn), SAEx (Ex, 10-16000 Nm), plus GST/GK gearbox solutions for 90 degree duty. Full order codes are subject to official manuals.

If you are selecting an electric actuator for a valve, or want to decide between multi-turn and part-turn or to match the torque rating and duty, please feel free to contact us. We can check the model together against your valve torque curve, power supply and fieldbus requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.