SAMSON 3730-6 Positioner - Technical Data & Ordering Code (14-digit)
Release time:2026-11-22 09:38:23 | Views:

The SAMSON 3730-6 is a separate design derived from the 3730-3 (HART) platform. Its defining feature is integrated supply-pressure and output-pressure sensors for online monitoring of air supply quality and valve thrust. Although it keeps the 3730-X name, its data sheet (T 8384-6 EN), 14-digit order code and Ex option set stand alone, including an exclusive Ex d[ja] option. This article decodes its order code digit by digit and clarifies the boundaries against the 3730-3 and 3731 series.

I. Product Positioning

ItemDescription
BrandSAMSON
Model3730-6 (pressure-monitoring type, a separate design outside the 3730-0-5 family)
Base platform3730-3 (HART) platform plus supply / output pressure sensing module
CommunicationHART (4-20 mA two-wire) with superimposed pressure measurement transmission
Explosion protectionMainly intrinsic safety Ex ia; exclusive Ex d[ja] / Ex db[ja] option (codes 210 / 211)
Order code / data sheet14 digits; T 8384-6 EN plus NA 0122
Safety version3730-6 TS (TROVIS SAFE) for SIS switching safety applications

The value of the 3730-6 is the integration of positioning and pressure diagnostics in one device, suited to early warning of air supply loss, actuator leakage or seat loading.

Source: SAMSON official data sheets T 8384-6 EN and NA 0122; certificates PTB 10 ATEX 2007 and IECEx PTB 10.0057.

SAMSON 3730 series positioner illustration
SAMSON 3730 series positioner illustration; for illustration only, not the actual model; parameters subject to the official data sheet

II. Pressure Monitoring and Technical Data

ParameterDescription
Pressure monitoringIntegrated supply-pressure and output-pressure sensors with online monitoring and alarms
Input signal4-20 mA two-wire; HART communication
Supply pressure1.4-7.0 bar (common platform parameter)
Platform dataTravel 3.6-300 mm; angle 24-100 degrees; IP66/67; -40 to +80 C; same as 3730-0-5
Self-diagnosticsEXPERT / EXPERTplus with NE 107 status indication
Exclusive Ex optionEx d[ja] IIC T6 (ATEX II 2G, code 210) / Ex db[ja] IIC T6 (IECEx, code 211)
Safety version thresholds3730-6 TS emergency shutdown at 3.8 mA / 4.4 mA (set by the function digit)

The 3730-6 has neither the fixed bus identification digit of the 3730-4 / 3730-5 nor the 16-digit assignment of the 3730-3; its order code has 14 digits with explosion protection occupying the first three.

Source: SAMSON official data sheets T 8384-6 EN and NA 0122.

III. 14-Digit Order Code, Digit by Digit

Complete code = "3730-6" plus 14 digits. The official article-code skeleton is: x x x (Ex) x (limit) x (vent) x x (additional) x (external sensor) x (function) x (housing) x (special application) 0 0 0 (fixed). The table follows the Article code table of T 8384-6 EN.

PositionOptionCode and meaning (excerpt)
P1-P3Explosion protection (3 digits)000 none; 110 ATEX Ex ia; 111 IECEx Ex ia; 112 CCC / NEPSI Ex ia; 116 TR; 130 FM IS; 131 CSA Ex ia; 210 ATEX Ex d[ja]; 211 IECEx Ex db[ja]; 510 / 511 / 512 / 516 dust; 810 / 811 / 816 Ex nA
P4Inductive position switch0 none; 1 SJ2-SN (NC)
P5Venting / solenoid0 none; 1 solenoid 24 V DC; 2 forced venting 24 V DC
P6-P7Additional equipment00 none; 10 position transmitter; 20 leakage sensor incl. cable and screws; 30 binary input
P8External position sensor0 none; 1 with 10 m connecting cable; 2 prepared for connection without sensor
P9Function0 standard control valve; emergency shutdown: 3.8 mA / 4.4 mA per order code
P10Housing material1 aluminum (standard); 2 stainless steel
P11Special application0 none; 1 paint-compatible; 2 rear-sealed 1/4-18 NPT exhaust port; 6 with VDI/VDE 3847 adapter; 7 additional vent hole
P12-P14Fixed positions0 / 0 / 0

Example: 3730-6 110000000000100 reads as ATEX Ex ia intrinsic safety, no additional equipment, aluminum housing and paint-compatible version. Verify the actual order against data sheet T 8384-6 EN and the official selection tool.

Source: SAMSON official data sheet T 8384-6 EN (Article code table); certificates PTB 10 ATEX 2007 and IECEx PTB 10.0057.

IV. Ex Options and the Difference between Intrinsic Safety and Flameproof Enclosure

CodeCertificationType of protection (excerpt)
110ATEX (PTB 10 ATEX 2007)II 2G Ex ia IIC T6 Gb; II 2D Ex ia IIIC T80 C Db
111IECEx (PTB 10.0057)Ex ia IIC T6 Gb; Ex ia IIIC T80 C Db
112CCC Ex / NEPSIEx ia IIC T4...T6 Gb; Ex ia IIIC T80 C Db
130 / 131FM / CSAIntrinsically safe IS / Ex ia IIC T4/T5/T6, Class I Zone 0
210ATEX (PTB 10 ATEX 2007)II 2G Ex d[ja] IIC T6 Gb; II 2D Ex tb IIIC T80 C Db
211IECEx (PTB 10.0057)Ex db[ja] IIC T6 Gb; Ex tb IIIC T80 C Db
810 / 811ATEX / IECExEx nA ic IIC T6 Gc; Ex tc IIIC T80 C Dc

Red line: Ex ia intrinsic safety is NOT Ex d[ja] flameproof enclosure. Codes 110/111/112/130/131 are intrinsically safe and must not be wired or promised as flameproof. Only 210/211 are flameproof: use certified cable entries per EN 60079-1, provide equipotential bonding and never open the cover while energized. If a project merely says "flameproof" without certification and code, please consult for confirmation.

Source: SAMSON official data sheet T 8384-6 EN explosion protection certificate summary; certificates PTB 10 ATEX 2007 and IECEx PTB 10.0057; wiring principles per EN 60079-14 and EN 60079-1.

V. Boundaries against the 3730-3 and 3731 Series

Dimension3730-63730-33731-3 / 3731-5
PositioningSeparate pressure-monitoring designFull-featured HART modelFlameproof Ex d series
Order code14 digits (Ex uses 3 digits)16 digits (Ex uses 1 digit)15 digits (separate structure)
Data sheetT 8384-6 ENT 8384-3 ENT 8387-3 / T 8387-5 EN
Pressure monitoringYes (supply plus output pressure)NoNo
FlameproofExclusive Ex d[ja] options 210/211No Ex dSeries based on Ex d enclosures
Safety application3730-6 TS for SISNot applicablePer certificate / configuration

Prefer the 3731 series when flameproof enclosure is required without pressure monitoring; choose the 3730-6 when pressure monitoring is required and intrinsic safety or its exclusive Ex d[ja] is acceptable. The two are not interchangeable and their digit assignments must not be mixed.

Source: SAMSON official data sheets T 8384-3 EN, T 8384-6 EN, T 8387-3/5 EN and NA 0122.

VI. Selection Guide and Common Models

Selection guide: First confirm whether supply / output pressure monitoring is truly needed: if not, prefer the 3730-3 (HART); if yes, select the 3730-6 and fill the 14 digits for explosion protection (110/111/112 intrinsic safety, 210/211 flameproof), limit switch, venting, additional equipment, external sensor, function, housing and special application. Where flameproof enclosure dominates and pressure monitoring is not needed, choose the 3731 series. Ex ia and Ex d[ja] must be strictly distinguished.

Common models: 3730-6 (14-digit pressure-monitoring type) and 3730-6 TS (SIS safety version with emergency shutdown at 3.8 / 4.4 mA); related models are the 3730-3 (HART), 3730-4 (PA), 3730-5 (FF) and the 3731-3 / 3731-5 flameproof range.

If you are evaluating whether online pressure monitoring is needed, or want to verify the 14-digit order code and Ex options of a 3730-6 (especially the 210/211 flameproof options), please feel free to contact us. We can check the model and code against your diagnostic needs, area certification and air supply conditions.