The SAMSON 3730-1 and 3730-2 are non-communication digital positioners in the 3730 family: the 3730-1 adds an LCD and autotune, while the 3730-2 further provides full parameterization and EXPERTplus self-diagnostics. Both use 16-digit order codes and share the 3730 platform pneumatics and mounting interfaces. This article compares their differences, data, codes and typical applications.

I. Product Positioning

Item3730-13730-2
BrandSAMSONSAMSON
PositioningBasic digital positionerFull-featured digital positioner
Display / operationLCD plus single rotary pushbuttonLCD plus single rotary pushbutton
AutotuneYes (INIT key)Yes (INIT key)
Self-diagnosticsBasicEXPERTplus enhanced diagnostics
CommunicationNoneNone
Data sheetT 8384-1 EN (TROVIS version T 8484-1)T 8384-2 EN (subject to the latest official data sheet)

Both are digital models without a fieldbus, distinct from the purely mechanical 3730-0 and the HART-enabled 3730-3. Some official overview catalogs list 3730-0/-1/-3/-4/-5/-6 but do not list the 3730-2 separately; confirm availability with the data sheet and official selection tool for a specific project.

Source: SAMSON official data sheets T 8384-1 EN, T 8384-2 EN and NA 0122; SAMSON official product catalog (Ed. Nov 2025).

SAMSON 3730 series intelligent electro-pneumatic positioner
SAMSON 3730 series positioner, same-series illustration; for illustration only, not the actual model; parameters subject to the official data sheet

II. Core Technical Data

ParameterTypical value for 3730-1 / 3730-2
Input signal4-20 mA two-wire, reverse-polarity protected
Supply pressure1.4-7.0 bar (software limit 1.4 / 2.4 / 3.7 bar)
Travel / angle3.6-300 mm linear; 24-100 degrees rotary
Hysteresis / sensitivityless than or equal to 0.3% / 0.1%
CharacteristicsLinear / equal percentage / reverse equal percentage (configurable)
Ingress protectionIP66 / IP67 optional
Ambient temperature-40 to +80 C (Ex option dependent)
Electrical interfaceM20x1.5; 2 x 1/2 NPT optional
Software / interfaceTROVIS-VIEW plus SSP (RS-232 / USB)

Both models share one platform; differences lie mainly in diagnostics and configurable functions. Exact figures are subject to the respective data sheets.

Source: SAMSON official data sheets T 8384-1 EN, T 8384-2 EN and NA 0122.

III. Functional Differences and Diagnostics

Dimension3730-13730-2
ParameterizationLocal knob and menuLocal knob and menu plus TROVIS-VIEW
Self-diagnosticsBasic status indicationEXPERTplus with NE 107 status
Optional additional equipmentLimit switch / solenoid (per data sheet)Position transmitter / external sensor / leakage sensor / binary input
Typical positioningCost-sensitive applications needing LCD and autotuneApplications needing full diagnostics and parameter records
HART / fieldbusNot supportedNot supported (select 3730-3/4/5 for communication)

If HART, PROFIBUS PA or FF is required, choose the 3730-3/4/5 directly and do not promise communication on the 3730-1/2. If Ex d flameproof enclosure is required, choose the 3731 series.

Source: SAMSON official data sheets T 8384-1 EN, T 8384-2 EN, T 8384-3/4/5 EN and T 8387-3/5 EN.

IV. 16-Digit Order Code, Digit by Digit

Complete code = "3730-1" or "3730-2" plus 16 digits; no fixed bus identification digit. The table follows the published 3730 platform assignment; positions marked with an asterisk are subject to data sheets T 8384-1 / T 8384-2 EN and the official ordering tool.

PositionOptionCode and meaning (excerpt)
P1Explosion protection0 none; 1 ATEX Ex ia IIC; 3 CSA; 5 dust; 8 Ex nA
P2Inductive limit switch0 none; 1 SJ2-SN (NC)
P3Solenoid valve0 none; 4 24 V DC
P4-P7Additional equipment (mutually exclusive)Position transmitter 1000; external sensor; analog input; leakage sensor; binary input; 0000 none
P8Self-diagnostics4 EXPERTplus (3730-2); 0 standard
P9Fixed position0
P10Housing material0 aluminum; 1 stainless steel
P11-P12Fixed positions0 / 0
P13Special application0 none; 1 paint-compatible; 2 1/4 NPT exhaust; 6 VDI/VDE 3847 adapter; 7 additional vent
P14Fixed position0
P15-P16Special version marker00 standard; 12 IECEx; 34 Ex tb; 13 Ex nA; 14 EAC

Platform-based example: 3730-2 1100000400000000 reads as ATEX intrinsic safety, SJ2-SN limit feedback, EXPERTplus diagnostics and standard aluminum housing. The exact combination must be generated and compatibility-checked by the official selection tool.

Source: SAMSON official data sheets T 8384-1 EN, T 8384-2 EN and NA 0122; digit structure per the published T 8384-3 EN table. Asterisked positions must be confirmed with the official ordering tool.

V. Applications and Commissioning Points

ApplicationRecommendation
Ordinary single-acting control valve3730-1 with basic ATEX Ex ia configuration; commission with INIT autotune
Position feedback to DCSSelect the P4-P7 position transmitter (4-20 mA feedback) or a discrete limit switch
Diagnostic records required3730-2 with EXPERTplus; read parameters and status via TROVIS-VIEW
Communication requiredMove to 3730-3 (HART) / 3730-4 (PA) / 3730-5 (FF)
Flameproof hazardous areaMove to 3731-3 / 3731-5 (Ex d); Ex ia must not be treated as Ex d
Pressure monitoring requiredMove to the 3730-6 (14 digits, supply / output pressure monitoring)

Commissioning sequence: verify nameplate spring range and fail-safe action (FA / FE), confirm air quality and supply, set ATO / ATC and feedback rod pin position, run INIT initialization, check terminals and Ex sealing, then record the configuration.

Source: SAMSON official data sheets T 8384-1 EN, T 8384-2 EN, NA 0122 and the 3730 series mounting and start-up manual.

VI. Selection Guide and Common Models

Selection guide: The choice between the 3730-1 and 3730-2 hinges on whether EXPERTplus diagnostics and full parameterization are needed: select the 3730-1 for LCD and autotune only, and the 3730-2 for diagnostics. Neither has communication; move to 3730-3/4/5 for HART / PA / FF and to the 3731 or 3730-6 for flameproof enclosure or pressure monitoring. The final 16-digit code must come from the official ordering tool.

Common models: 3730-1 (basic digital) and 3730-2 (full-featured digital); adjacent models are the 3730-0 (basic mechanical), 3730-3 (HART), 3730-4 (PROFIBUS PA), 3730-5 (FF), 3730-6 (pressure monitoring) and the 3731-3/3731-5 flameproof models.

If you need to choose between the 3730-1 and 3730-2 non-communication digital positioners, or want to verify the diagnostic and additional-equipment digits in an order code, please feel free to contact us. We can check the configuration and code against your diagnostic needs, feedback signal and certification requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.