Control valve noise is a common companion of high-differential service, arising from aerodynamic noise, hydrodynamic noise (including cavitation) and mechanical vibration. Noise prediction is generally based on IEC 60534-8-3 (gas) and IEC 60534-8-4 (liquid). This article addresses Masoneilan (a Baker Hughes brand, not GE) control valves and covers noise sources and criteria, evaluation methods, anti-noise trim selection paths and engineering cautions. Noise data for specific models are subject to Masoneilan official samples and sizing software, and model parameters are not invented.

I. Noise Sources and Classification

SourceMechanismCharacteristicTypical service
Aerodynamic noiseHigh-velocity gas at vena contracta, shock waves and jet shearMostly high frequency, rising with differential and velocityHigh-differential gas / steam
Hydrodynamic noiseTurbulence, cavitation bubble collapseCrackling sound, high-frequency pulsesHigh-differential liquid, cavitation
Flashing noiseHigh-velocity two-phase erosionContinuous hissingFlashing where P2 <= Pv
Mechanical noisePlug guide wear, looseness, resonanceLow-frequency vibration and impactWear, poor assembly

Sizing must first determine whether the noise is aerodynamic, hydrodynamic or mechanical, then choose the corresponding prediction standard and mitigation.

Source: IEC 60534-8-3 / IEC 60534-8-4 and recognized engineering classification; specific model data are subject to official samples.

Masoneilan control valve noise and anti-noise trim selection reference
Masoneilan digital positioner, appearance reference only, not the actual model; parameters subject to official samples

II. Prediction Standards and Evaluation

ItemDescription
Gas noise standardIEC 60534-8-3: Industrial-process control valves Part 8-3: Noise considerations - aerodynamic noise
Liquid noise standardIEC 60534-8-4: hydrodynamic noise and cavitation prediction
Common indexesSound pressure level dB(A), sound power level, frequency spectrum
Evaluation pointUsually sound pressure level at 1 m from the valve body, considering piping attenuation
Allowable valueSet by project specification and occupational health requirements; common target around 85 dB(A)
Input dataMedium, P1/P2, temperature, flow, molecular weight / density, specific heat ratio, pipe wall thickness

The table gives a general evaluation basis; actual noise calculation must follow standard formulas or manufacturer sizing software. Masoneilan noise data for specific models are subject to official samples and sizing software.

Source: IEC 60534-8-3, IEC 60534-8-4. Allowable values and evaluation points are general engineering practice; specifics are subject to project specifications and official samples.

III. Aerodynamic Noise Control

MeasurePrincipleApplicable
Multi-stage pressure-reduction trimDistribute total differential over stages, lowering exit velocity per stageHigh-differential gas / steam
Low-noise cage trimMulti-hole throttling with jet interference to reduce noiseGas pressure-reducing stations
Diffuser / outlet diffuser tubeReduce outlet Mach number and jet intensityHigh outlet velocity
Larger size / lower differentialReduce velocity and pressure drop per stageNew-project sizing stage
Pipeline silencer / thick-wall pipeEnd-of-line treatment and piping attenuationWhen noise still exceeds limits

The core of gas noise reduction is "lower vena contracta and outlet velocity, distribute the pressure drop". Anti-noise trim usually affects Cv and rangeability, so size and control quality must be rechecked.

Source: IEC 60534-8-3 and common engineering noise-control practice; specific Masoneilan low-noise trim models and parameters are subject to official samples.

IV. Liquid Noise and Cavitation Noise Control

PhenomenonNoise characteristicMitigation direction
Turbulent noiseBroadband hiss rising with velocityLower velocity, optimize flow passage
Cavitation noiseCrackling sound, high-frequency pulsesEliminate cavitation: staged reduction keeps each stage above Pv
Flashing noiseContinuous hiss, two-phase flowControl velocity, use angle valve / expanded chamber, hard materials
Mechanical noiseLow-frequency impact, resonanceCheck guide clearance, fastening and supports

Liquid noise mitigation largely overlaps cavitation / flashing mitigation: first judge the relationship between P2 and Pv, then decide whether to eliminate cavitation (staged reduction) or mitigate flashing (material and velocity).

Source: IEC 60534-8-4; specific mitigation trim is subject to Masoneilan official samples and sizing software.

V. Selection Guide and Common Practice

Selection guide: Noise control follows "judge source first, calculate level next, select trim then, verify size last". Gas noise is checked per IEC 60534-8-3, liquid noise and cavitation per IEC 60534-8-4. For any specific model's noise data, low-noise trim model and allowable differential, always rely on official samples / sizing software; if unavailable write "please consult for confirmation" and do not invent model parameters.

Common practice: For high-differential gas prefer low-noise cage / multi-stage trim with a diffuser; for high-differential liquid eliminate cavitation before addressing noise; finalize all schemes with manufacturer sizing software and official samples, and recheck Cv, rangeability and actuator thrust.

If you are troubled by excessive noise under high-differential service and want to decide which anti-noise trim to use or whether a diffuser is needed, please feel free to contact us. We can check the noise criteria and selection direction together against your medium, differential and piping conditions.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.