Home » Service & Support » Technical Documentation
Fisher 1061 / 1066 Piston Actuators - Technical Data & Selection
Release time:2026-11-22 09:38:23 | Views:

Fisher 1061 and 1066 are both pneumatic piston rotary (quarter-turn) actuators for throttling or on-off duty on ball, butterfly and eccentric plug valves. The 1061 uses a pneumatic pilot with a splined piston shaft; the 1066 / 1066SR are double-acting piston rotary actuators with spring-return variants. This article covers construction, technical data, selection calculations and installation points.

I. Product Positioning

ItemDescription
BrandFisher (Emerson)
Series1061 pneumatic pilot rotary actuator; 1066 / 1066SR piston rotary actuators
TypePneumatic piston quarter-turn actuators
ServiceThrottling or on-off duty on Vee-Ball, eccentric butterfly, butterfly, eccentric plug and triple-eccentric valves
Action1061 double-acting with no built-in fail-safe; 1066 double-acting; 1066SR spring-return
ControlPositioner for throttling, two-position signal for on-off
Compatible positioners3710 / 3610JP / 3620JP pneumatic or electro-pneumatic; FIELDVUE DVC6200 digital valve controller
Main documentsProduct Bulletin 61.2:1061 (D100095X012); 1066 / 1066SR Instruction Manual (D100331X012); SIL Safety Manual (11745518)

Although both are piston rotary designs, the 1061 is a pneumatic-pilot splined-shaft design about 30% smaller than comparable units and has no built-in fail-safe action, requiring external air circuitry for fail-safe operation. The 1066 is a double-acting on-off actuator and the 1066SR adds spring return. They are not interchangeable.

Source: Emerson / Fisher official product pages, Product Bulletin 61.2:1061 (D100095X012), Instruction Manual D100331X012. Section III data is web-sourced and annotated in place.

Fisher 2052 actuator
Fisher 2052 actuator, appearance reference only, not the actual model in this article; parameters subject to official data sheets

II. 1061 Technical Data and Construction

ItemDescription
ItemParameter / Description
ConstructionPneumatic pilot-operated rotary, double-acting; splined piston shaft with splined clamp linkage for low backlash
Valve connectionPDTO (push-down-to-open) or PDTC (push-down-to-close), four mounting orientations
Size and operating pressureDouble-acting 20 psig (1.5 bar) to 100 psi (7 bar), 80 psig (5.5 bar) standard; spring-return 80 psig standard
RotationStandard adjustable travel stops of at least 80 degrees; fixed 84 degrees on certain sizes; fixed travel available
TorqueDouble-acting gives the same torque at all angles; series maximum about 150,000 lbf-in (approx. 16,950 N-m per official table 6)
TemperatureStandard -40 to 80 C (-40 to 176 F)
Fail-safeNo built-in fail-open / fail-close protection; external air circuitry required
HandwheelOptional side-mounted handwheel for auxiliary / emergency manual operation
Accessories377 series trip valves; DVC6200 and other positioners
SourceProduct Bulletin 61.2:1061 (D100095X012), SIL Safety Manual (11745518)

The 1061 is about 30% smaller than comparable actuators, fully encloses the valve connection while allowing packing adjustment without disassembly, and provides a highly visible travel indicator. It is rugged and corrosion-resistant for throttling and on-off duty on rotary valves such as Vee-Ball.

Source: Emerson / Fisher official product pages and Product Bulletin 61.2:1061 (D100095X012). Parameters are subject to the official bulletin.

III. 1066 / 1066SR Technical Data (Web-Sourced)

Item10661066SR
Sizes20, 27, 7520, 27, 75
Max allowable cylinder pressureSizes 20/75: 8.3 bar (120 psig); size 27: 4.1 bar (60 psig)Sizes 20/75: 8.3 bar; size 27: up to 8.3 bar depending on spring
Minimum recommended pressure2.8 bar (40 psig)3.4 bar (50 psig)
Maximum rotation90 degrees, travel stops adjustable to 60 degreesSame
Max breakout torqueSizes 20/27: up to 225 N-m (2000 lbf-in); size 75: up to 850 N-m (7500 lbf-in)Size 20: 111 N-m; size 27: 225 N-m; size 75: 478 N-m
Approximate weightSize 20: 15 kg; 27: 28 kg; 75: 38 kgSize 20: 15 kg; 27: 34 kg; 75: 49 kg
TemperatureNitrile O-rings -40 to 82 C; fluorocarbon -18 to 149 CSame
Pressure connection1/4 NPT femaleSame
OptionsDVC6200, 3710/3720 positioners, TopWorx DXP limit switch, solenoid, bypass valve, trip valve, handwheelSame

This data is from web search, sources: https://www.emerson.com/documents/automation/manual-type-1066-on-off-piston-rotary-actuator-h-mounting-adaptation-fisher-en-142240.pdf and https://www.manualslib.com/manual/1893456/Emerson-Fisher-1066.html. The manual number is D100331X012 (October 2012). The figures come from the official installation manual; exact order configuration, materials and approvals are subject to the nameplate and latest manual.

Source: Fisher 1066 / 1066SR Instruction Manual D100331X012; web-sourced data from https://www.emerson.com/documents/automation/manual-type-1066-on-off-piston-rotary-actuator-h-mounting-adaptation-fisher-en-142240.pdf and https://www.manualslib.com/manual/1893456/Emerson-Fisher-1066.html

IV. Working Principle and Construction Comparison

Dimension10611066 / 1066SR
Driving principlePneumatic pilot controls pressure differential across piston; splined shaft drives valve shaft directlyDouble-acting piston rotates under cylinder pressure; 1066SR adds bias spring for fail position
Fail modeNo built-in fail-safe; external circuitry / trip valves required1066 double-acting without spring; 1066SR spring-return for fail-open / fail-close
BacklashSpline plus clamped linkage, low backlashDepends on mounting adaptation and shaft connection
Position indicationHigh-visibility travel indicatorGraduated scale and pointer
Typical positionersDVC6200, 3710, 3610JP, 3620JPDVC6200, 3710 / 3720, TopWorx DXP
ApprovalsSIL Safety Manual (11745518) listedPED / ATEX etc. per specific certificate

Both are piston rotary designs whose torque output depends directly on supply pressure. With spring return, net available torque must be reduced by spring torque: at 60/70 psig on the 1061 net torque drops significantly and is no longer balanced with spring torque, hence 80 psig is the standard recommendation.

Source: Fisher Product Bulletin 61.2:1061 (D100095X012) and Instruction Manual D100331X012. Net torque statements are subject to the official bulletin.

V. Selection Calculation and Installation Points

ItemDescription
StepContentCaution
1. Determine valve torqueRequired torque from valve type, size, differential pressure and flow direction, with marginCalculate closing torque and breakout torque separately
2. Choose actionFail-safe requirement decides 1066 double-acting vs 1066SR spring-return; 1061 needs external fail-safe air circuitDo not assume the 1061 fails safe by itself
3. Verify supply1061 double-acting 1.5-7 bar, 80 psig standard; 1066 min 2.8 bar / 1066SR 3.4 barDo not exceed maximum allowable cylinder pressure
4. Check torqueNet output torque at selected supply must exceed required torqueDeduct spring torque for spring-return versions
5. Check rotationStandard 90 degrees, stops adjustable to 60 degrees on 1066; 1061 at least 80 degreesConsult for ranges beyond standard
6. Install and commissionFix per mounting adaptation, connect positioner and verify full travelMind PDTO / PDTC and rotation direction

Air must be clean, dry and oil-free per ISA 7.0.01 / ISO 8573-1; tubing should be short with adequate bore. Torque data are subject to official manuals / curves; this article does not perform safety integrity arguments.

Source: Fisher 1061 bulletin D100095X012, 1066 manual D100331X012; air standard ISA 7.0.01 / ISO 8573-1. Required valve torque must come from valve data.

VI. Selection Guide and Common Models

Selection guide: First choose between the 1061 (pilot-operated, double-acting, external fail-safe) and the 1066 / 1066SR (double-acting / spring-return) based on valve torque and fail-safe requirements. Then verify supply range, rotation, mounting adaptation and shaft diameter; determine positioner and limit switch accessories; finally check approvals and temperature options. Write subject to official manual / nameplate or please consult for confirmation for unavailable dimensions, weights and approvals. The 1066 figures are web-sourced and annotated in the text.

Common models: 1061 (pneumatic pilot rotary actuator, double-acting, optional side handwheel and DVC6200); 1066 (double-acting piston rotary actuator, sizes 20/27/75); 1066SR (spring-return version, sizes 20/27/75).

If you are selecting feedback rods and mounting kits, verifying spring range and supply pressure, or making a preliminary Cv and size calculation, please feel free to contact us. We can work through the selection and verification together against your valve service, interface standards and installation conditions.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.