A partial stroke test (PST) moves the actuator through a small travel without interrupting the process and compares the valve signature to verify that the valve can still move. On the Fisher FIELDVUE DVC6200, PST capability resides in the ODV diagnostics level and in the dedicated DVC6200 SIS model. This article explains the PST principle, SIS technical data, SIL application boundaries and implementation points.
I. Product Positioning
| Item | Description |
|---|
| Brand | Fisher (Emerson) |
| Series | FIELDVUE DVC6200 / DVC6200 SIS digital valve controllers |
| Function | PST verifies in-service valve movability without interrupting the process; periodic proof-testing for SIS / ESD loops |
| Standards | IEC 61508 / IEC 61511 functional safety; exida third-party certification |
| PST availability | ODV diagnostics level on DVC6200H (HART only); PS level on DVC6200F; standard on DVC6200 SIS |
| Main documents | DVC6200 manuals D103409X012 / D103605X012; DVC6200 SIS manual D103557X012 |
Red line: ODV is valid only on the HART protocol version DVC6200H; DVC6200F (FF) and DVC6200P (PROFIBUS PA) do not offer ODV. The PS level on DVC6200F is a different partial stroke test option and must not be written as ODV.
Source: Fisher FIELDVUE DVC6200 manuals D103409X012 / D103605X012 and DVC6200 SIS manual D103557X012. Brand ownership: Emerson.

Fisher DVC6200 digital positioner, same model, for selection reference only
II. PST Principle and Trigger Methods
| Item | Description |
|---|
| Stage | Content | Description |
| Preparation | Record baseline valve signature | Reference curve established during full-stroke commissioning |
| Stroke drive | Move a preset small travel toward closed (or open) position | Typically a percentage of full travel; set by safety requirements |
| Signature comparison | Compare slope, hysteresis and breakpoints of travel-pressure curve | Detects seat sticking, excessive packing friction, air leaks |
| Result | Pass / fail plus alarm | Uploaded over HART or digital output; can be recorded as NE107 status |
| Trigger | HART command / discrete input / local button / internal scheduler | Depends on model and configuration; SIS supports safety-related triggering |
| After test | Automatic return to original position | Normal control continues; process disturbance during the test must be assessed |
PST covers only a fraction of the travel. It cannot replace a full-stroke test and is not the sole evidence of valve integrity. Test percentage, interval and criteria should be defined in the safety requirements specification and assessed together with process disturbance risk.
Source: Fisher FIELDVUE DVC6200 manual D103605X012 (ODV / PST levels) and DVC6200 SIS manual D103557X012. Test parameters are subject to official and safety manuals.
III. DVC6200 SIS Technical Data
| Item | Description |
|---|
| Parameter | Specification / Description |
| Communication | HART 5 or HART 7 |
| Input signal | 4-20 mA DC; point-to-point minimum loop voltage 9.5 V (analog) / 10 V (HART); max 30 V DC with overcurrent and reverse polarity protection |
| Supply pressure | Max 10.0 bar (145 psig) or actuator rating, whichever is lower; per ISA 7.0.01 and ISO 8573-1 (particles Class 7 / oil Class 3 / dew point Class 3) |
| Output signal | Pneumatic output up to full supply pressure; travel span 0.4-9.5 bar; double-acting / single-acting direct / reverse |
| Electronic output | Integral 4-20 mA position transmitter (8-30 V DC, reference accuracy 1% / safety accuracy 5%, NAMUR NE43) plus integral switch |
| Steady air consumption | Low-bleed relay: 0.056 Nm3/h at 1.4 bar, 0.184 Nm3/h at 5.5 bar (average) |
| Max output capacity | 10.0 Nm3/h at 1.4 bar; 29.5 Nm3/h at 5.5 bar |
| Ambient temperature | -52 to +85 C |
| Independent linearity | Typical +/-0.50% of output span |
| Input impedance | Equivalent 500 ohm (10 V at 20 mA) |
| Ingress protection | CSA / FM Type 4X, IP66; ATEX / IECEx IP66 |
| Connections | Supply/output 1/4 NPT female; tubing 3/8 in; vent 3/8 NPT; electrical 1/2 NPT or M20 |
| Actuator compatibility | Linear 6.5-606 mm; rotary 45-90 degrees |
| Weight | Aluminum 3.5 kg / stainless 8.6 kg; DVC6205 SIS 4.1 kg; DVC6215 1.4 kg |
| Hazardous area approvals | CSA, FM, ATEX, IECEx, Lloyds Register, CUTR, INMETRO, KGS, NEPSI, PESO CCOE |
Source: Fisher FIELDVUE DVC6200 SIS manual D103557X012, Table 1-1 Specifications. Parameters are subject to the official manual.
IV. Diagnostics Levels and PST Availability
| Code | Meaning | PST | Protocol |
|---|
| AC | Automatic calibration via device communicator | No | DVC6200H; not for F / P |
| HC / FD | HART communication / fieldbus diagnostics, basic communication and alarms | No | HC for HART (DVC6200H), FD for FF (DVC6200F) |
| AD | Advanced diagnostics: communication diagnostics plus offline diagnostics (ValveLink) | No | HART / FF, not P |
| PD | Performance diagnostics: advanced plus online diagnostics (ValveLink) | No | HART / FF, not P |
| ODV | Optimized Digital Valve: all HC/AD/PD diagnostics plus PST and Lead/Lag set point filter | Yes (online verification of valve movability) | DVC6200H (HART) only |
| PS | Partial stroke action test | Yes | DVC6200F (FF) only, not H or P |
| SIS standard | SIS diagnostics plus PST plus low-bleed amplifier | Yes (standard) | DVC6200 SIS |
ODV is the fourth instrument level confirmed by the official manual, above PD performance diagnostics; PST is available only at this level. If PST is explicitly required, the selection must be ODV (HART) or an SIS model; never state that AD / PD include PST.
Source: Fisher FIELDVUE DVC6200 manual D103605X012 (diagnostic levels), D103409X012; DVC6200 SIS manual D103557X012.
V. SIL Application Points
| Item | Description |
|---|
| Dimension | Requirement / Description |
| Safety level | DVC6200 SIS is SIL3 certified and exida certified for ESD emergency shutdown positioner service |
| Safety manual | Evaluate the complete safety instrumented function per the official SIL Safety Manual and IEC 61508 / 61511 |
| Device and loop | Device-level certification does not make the loop compliant; sensor, logic solver, actuator and valve body must all be included |
| PST and SIL | PST reduces undetected dangerous failures and shortens proof-test intervals; diagnostics cannot replace SIL certification |
| Proof test | Periodic full-stroke proof testing remains mandatory; PST is only supplementary |
| Air supply | Low-bleed amplifier is standard; air must meet ISA 7.0.01 / ISO 8573-1 |
SIL applications must be verified by a qualified functional safety team per the official safety manual. This article is for selection and principle explanation only and is not a safety integrity argument.
Source: Fisher FIELDVUE DVC6200 SIS manual D103557X012, Fisher 1061 SIL Safety Manual (11745518) and other official data; functional safety assessment is subject to official safety manuals.
VI. Selection Guide and Common Models
Selection guide: First decide whether PST and SIL are needed. For general throttling without PST, HC / AD / PD is sufficient. For online verification of valve movability, choose DVC6200H + ODV on HART loops and DVC6200F + PS on FF loops. For ESD safety instrumented systems choose DVC6200 SIS. Then verify area approval codes (Ex ia and Ex d strictly distinguished; write please consult for confirmation if unavailable), air quality, travel range and actuator compatibility. The HART-only restriction of ODV is a red line and must not be promised on FF / PA models.
Common models: DVC6200H (HART) with ODV diagnostics; DVC6200F (FF) with PS diagnostics; DVC6200 SIS (HART 5 / HART 7, standard PST and low-bleed amplifier, SIL3 exida certified). Example: DVC6200-SIS 1D_2A_3A_4A_5A_6B_7F_8D_SV H7.
If you are verifying a positioner model, spare part or diagnostics level, or want to confirm air purification and area approval requirements, please feel free to contact us. We can check the model and configuration together against your protocol, actuator interface and site approval conditions.
Orders & Inquiries
Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China
The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.