Home » Service & Support » Technical Documentation
Fisher Positioners - Air Supply Interfaces & Piping Accessories Selection List
Release time:2026-11-21 13:41:01 | Views:

Reliable positioner operation begins with a clean, stable instrument air supply. The Fisher 67CFR is a direct-acting instrument supply filter regulator of the 67C series, delivering reduced-pressure air to positioners, converters and other instruments through a 1/4" NPT connection, 5 μm filtration and an internal relief valve. This article covers air supply connection specifications, filter regulator selection, a piping accessory checklist and matching points, and makes clear that the 67CFR connection is 1/4" NPT only, never 1/2".

I. Product Positioning

ItemDescription
BrandFISHER (an Emerson brand)
Core product67CFR filter regulator (67C series, direct-acting instrument supply regulator)
PurposeSupplies stable, clean reduced-pressure air to positioners, converters and other instruments
Connection1/4" NPT (67C platform); the 67D platform is 1/2" NPT
Matched equipmentValve positioners, electro-pneumatic converters, solenoid valves, cylinder / diaphragm actuators and other pneumatic devices
SourceFisher official "67C Series Instrument Supply Regulators" technical manual (Form 5469, May 2014) and 67D series regulator technical manual (document 5858)

The red line comes first: the 67CFR belongs to the 67C platform, with a 1/4" NPT connection only and main valve Cv 0.36; the 67DFR belongs to the 67D platform, with a 1/2" NPT connection and Cv 1.33. The two differ in size and flow capacity, their parameters must not be interchanged, and the 67CFR must never be written as "1/2 optional".

Source: Fisher official technical manuals Form 5469 (67C series) and document 5858 (67D series); the Form 5469 number was verified online against the Emerson public manual. Parameters are subject to the official manual and nameplate / order.

Fisher 67CFR filter regulator / air supply regulation
Fisher 67CFR filter regulator, same-brand product photo, for selection reference only

II. Air Supply Connection Specifications

Item67CFR (67C platform)67DFR (67D platform)
Body connection1/4" NPT (a second 1/4" NPT outlet can take a gauge or be plugged)1/2" NPT
Main valve flow coefficient Cv0.36 (Cq 11.7)1.33
Maximum inlet pressure250 psig (17.2 bar)Per official manual
Outlet pressure range0-20 / 0-35 / 0-60 / 0-125 psig, four ranges0-35 / 0-125 psig, etc. (see manual)
FilterStandard 5 μm polyethylene; options 5 μm cellulose / 40 μm PVDF or stainless steelWith 5 μm filter
Internal relief valveCv 0.045 (only for very small seat leakage, not complete overpressure protection)With internal relief valve
WeightAbout 0.5 kg (1 lb)Per official manual

When paired with a positioner, the common outlet pressure ranges are 0-20 or 0-35 psig, chosen by the instrument's required supply pressure. The internal relief valve Cv is only 0.045, serving only very small seat leakage and not complete overpressure protection; if inlet pressure may exceed the downstream equipment rating, a separate overpressure / limiting device is required.

Source: Fisher official technical manuals Form 5469 and 5858 (CN86 / CN87 / CN1800). The 67CFR is 1/4" NPT only and must not be written as 1/2 optional.

III. Filter Regulator Selection Quick Guide

Selection follows five steps: size and flow, material and service, outlet spring range, gauge or not, and special options.

StepItemPoints
1Size and flow1/4" leads to the 67C platform (67CFR aluminum / 67CFSR stainless); 1/2" or high flow leads to the 67D platform (67DFR / 67DFSR)
2Material and serviceNormal air / budget → aluminum 67CFR; corrosive / food / pharma / coastal humidity → stainless 67CFSR
3Outlet spring0-20 green / 0-35 silver / 0-60 blue / 0-125 red psig; never adjust the spring beyond its calibrated upper limit
4Gauge or notChoose with / without gauge for local indication; supply + outlet dual gauge also available
5Special optionsFor downstream bleed on air failure choose the Smart Bleed check valve (6 psig differential setting); for maintenance-free draining choose the automatic drain valve

Media compatibility: NBR standard for normal air / instrument air; FKM for high temperature / corrosive chemicals; silicone VMQ for low temperatures but incompatible with hydrocarbon gas, and the standard polyethylene element is prohibited for high-aromatic services. Common order numbers: 67CFR-224 (0-35, no gauge), 67CFR-226 (0-125), 67CFR-235 (0-125 with gauge); the complete code is subject to the official manual and nameplate / order.

Source: Fisher official technical manuals Form 5469 and 5858 (CN86 selection quick guide). Digit-by-digit order differences are subject to the official catalog and nameplate / order, without assumption.

IV. Piping Accessory Checklist

A typical piping run from the main air supply to the positioner requires the following accessories, item by item.

AccessoryFunctionSelection / notes
Filter regulator (67CFR / 67DFR)Filters impurities, reduces and stabilizes pressure, supplies clean instrument airSelect by size Cv, outlet range and material; the 67CFR is 1/4" NPT
Fittings (NPT / compression / push-in)Connect the regulator, tubing and positioner air portThread specification must match the port (1/4" NPT, etc.); do not mix standards
Tubing (copper / stainless / polyurethane)Carries instrument air to the positioner and actuatorSelect by pressure, corrosion environment and routing; ensure cleanliness and sealing
Pressure gaugeLocal indication of supply / outlet pressureSingle gauge or supply + outlet dual gauge, brass / stainless; range matched to outlet setting
Automatic drain valveDrains condensate from the filter bowl, maintenance-freeFor configurations with a large-capacity drip well
Smart Bleed internal check valveOn air failure, downstream media bleeds back upstream through the check valveSet at 6 psig (0.41 bar) differential, used as needed
Mounting bracket / panel mountSecures the regulator on siteChoose by installation space and method

Source: Fisher official technical manuals Form 5469 / 5858 (CN86 matching accessories and spare parts tables). Tubing and fitting specifications are subject to site routing conditions and the official manual.

V. Matching with Positioner Air Ports

Different brands of positioner have different air supply connection specifications; refer to each official manual. The table below shows the checking aspects for common positioner air connections; confirm specific specifications where required.

Positioner (example)Air connection aspectHandling principle
Fisher FIELDVUE DVC6200Pneumatic and conduit connections are listed separately (official order table lists 1/4 NPT pneumatic, 1/2 NPT conduit and other options)Subject to the official order table and nameplate; confirm connection specifications where required
SAMSON 3730 seriesMatched per NAMUR / IEC 60534-6-1 mounting faces and air connectionSubject to official data sheets T 8384-x
SIPART PS2Supply and output connections on the right side of the housing, with optional gauge block / booster blockSubject to the Siemens official manual
General principleRegulator outlet, tubing bore and positioner air port must be consistentFor mismatched sizes, consult for confirmation; do not assume adapter specifications

The key to matching is consistency of connection size, pressure range and air cleanliness: the 67CFR outlet is 1/4" NPT; if the positioner air port differs, use compliant fittings and tubing to adapt, with specifications subject to both official manuals; where a model is unavailable, write "please consult for confirmation".

Source: Fisher 67C/67D official manuals (5469 / 5858) and Emerson FIELDVUE DVC6200 official product selection data (D104363X012, obtained online); each positioner's air port specification is subject to its own official manual.

VI. Selection Guide and Common Models

Selection guide: 1. confirm the required size and flow: for a single instrument / low flow use the 67C platform 67CFR (1/4" NPT, Cv 0.36); for higher flow / multi-instrument headers use the 67D platform 67DFR (1/2" NPT, Cv 1.33); 2. choose the outlet spring range by instrument supply pressure (commonly 0-20 or 0-35 psig); 3. choose material by medium (aluminum / stainless); 4. select gauge, automatic drain, Smart Bleed check valve and other options as needed; 5. complete the set with fittings, tubing and a pressure gauge, keeping connection sizes consistent; 6. the 67CFR is 1/4" NPT only, never 1/2 optional; the internal relief valve is not complete overpressure protection and a separate device is required where limits may be exceeded; the complete order code is subject to the official manual and nameplate / order.

Common models: 67CFR-224 (0-35, no gauge), 67CFR-226 (0-125), 67CFR-235 (0-125 with gauge), 67CFR-237 (0-60, incl. 67CF-1663-38512), 67CFR-239 (1/4 NPT, 0-125, with gauge, incl. 67CF-1663-38550); the same platform includes stainless 67CFSR, plus the 67D platform 67DFR / 67DFSR. Specific configurations are subject to the nameplate / order or official selection catalog.

If you are arranging an air supply for a positioner, want to confirm the 67CFR connection, outlet range and gauge configuration, or want to verify tubing and fittings, please feel free to contact us. We can check the configuration together against your supply conditions and the positioner air port specification.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.