| Rosemount Pressure Transmitters - Working Principle & Selection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-21 13:41:01 | Views: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rosemount (an Emerson brand) pressure transmitters are represented by the 3051 series, which uses capacitive or piezoresistive sensing elements together with silicone-oil isolation and microprocessor compensation to output 4-20 mA HART or fieldbus signals. This article organizes their working principle, 3051 / 2088 technical data, communication protocols and selection points based on Emerson official data, with delivered-model examples appended. I. Product Positioning
This delivery includes 3051TG3A2B21AS1KBQ4M5HR7 (3051TG gauge pressure transmitter), 3051GP3A2B21AB4M5Q4HR5 (3051GP gauge pressure transmitter), plus 3144PD6A2NAM5CQ4HR7 and 644HAKBJ2M5Q4 (temperature transmitters). The 3051TG / 3051GP are gauge pressure transmitters supporting multiple communication protocols with reference accuracy up to +/-0.04%. The above data was obtained via online search. Source: Emerson official site (emerson.com). Parameters are subject to the latest original-manufacturer data.
II. Working Principle (Capacitive / Piezoresistive Sensors)The following data was obtained via online search. Source: Emerson official Rosemount 3051 product data (https://www.emerson.com/is/content/emerson/en/measurement-instrumentation/technical/products/unaudited/documents/rosemount-3051.pdf).
Both principles follow the chain "isolating diaphragm, fill fluid, sensing diaphragm, electrical signal, microprocessor compensation, standard output". The isolating diaphragm keeps the sensor away from corrosive media, and the small fill-fluid volume reduces temperature drift. The microprocessor performs linearization, temperature compensation and zero / span calibration. Gauge (GP) uses atmosphere as the low-side reference, absolute (AP) uses a sealed vacuum, and differential (DP) measures the difference between two sides; the sensing principle is identical, with only the chamber connections differing. The above data was obtained via online search. Source: https://www.emerson.com/is/content/emerson/en/measurement-instrumentation/technical/products/unaudited/documents/rosemount-3051.pdf. The specific sensor configuration is subject to the official data of the corresponding model. III. 3051 Core Technical DataThe following data was obtained via online search. Source: Emerson official site (emerson.com), Rosemount 3051 product data.
The 3051T integrates the sensor, electronics and a single isolating diaphragm, with calibrated spans for gauge and absolute pressure from 0.3 to 10000 psi. The 3051GP has a calibrated span starting around 0 to 1.5 psi and up to 0 to 4000 psi. Selection must first fix the measurement type and span, then wetted materials and protocol, never just the appearance. The above data was obtained via online search. Source: Emerson official site (emerson.com). Parameters are subject to the latest original-manufacturer data. IV. Communication Protocols and Signal Output
HART allows a handheld communicator or asset management system to remotely read process variables, configure spans and diagnose faults without disturbing the 4-20 mA control signal. The 644 / 3144 temperature transmitters support HART / FF / PROFIBUS PA, with outputs of 4-20 mA / HART, FF and PROFIBUS PA. The above data was obtained via online search. Source: Emerson official site (emerson.com). The supported protocol range is subject to the ordering data of the specific model. V. Related Models and Temperature TransmittersThe following data was obtained via online search. Source: Emerson official site (emerson.com), Rosemount product data.
Temperature transmitters support Callendar-Van Dusen sensor matching to improve temperature accuracy; the 644H is head-mounted and the 3144PD is DIN-rail / field mounted. Pressure and temperature transmitters belong to different product lines but share the same protocol family, allowing unified configuration and diagnostics in one asset management system. The above data was obtained via online search. Source: Emerson official site (emerson.com). Functions and mounting are subject to the official data of the corresponding model. VI. Selection Guide and Common Models
Selection guide: Rosemount pressure transmitter selection follows "define measurement type and span, define protocol, define wetted materials, define accuracy and safety approval, define mounting". Note that 3051 and 2088 have different sensor configurations; HART / FF / PROFIBUS support must be confirmed against the ordering data of the specific model; intrinsic safety and flameproof enclosure are two different Ex forms and must be confirmed against the nameplate and certificates, writing "please consult for confirmation" when unavailable. Final selection is subject to Emerson official data and confirmation at the time of inquiry. Common models: This delivery includes 3051TG3A2B21AS1KBQ4M5HR7 (3051TG gauge), 3051GP3A2B21AB4M5Q4HR5 (3051GP gauge), 3144PD6A2NAM5CQ4HR7 and 644HAKBJ2M5Q4 (temperature transmitters); related series include 3051S, 2051, 4051S, 2088 and the 248 temperature transmitter. If you are selecting a pressure or temperature transmitter for a process, or want to confirm the span, protocol or wetted materials of a 3051 / 2088, please feel free to contact us. We can check the model and order code together against your media, span and system protocol. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |