Home » Service & Support » Technical Documentation
YTC Valve Positioners - Technical Data & Selection Rules
Release time:2026-11-21 13:41:01 | Views:

The YTC (Young Tech, Korea; official manuals are signed Rotork YTC Limited) YT-1000 / 1050 is a widely used electro-pneumatic valve positioner that converts a 4-20 mA DC signal into a pneumatic output. The range also includes the YT-1200 compact, YT-3300 smart HART and YT-2500 / 2600 explosion-protected versions. This article organizes parameters, options, Ex approvals and selection rules based on the official YTC product manual. No in-house YTC material is available; all online-sourced data is annotated with sources in the text, and parameters are subject to the official catalog.

I. Product Positioning

ItemDescription
BrandYTC (Young Tech Co., Korea; official manuals signed Rotork YTC Limited)
SeriesYT-1000 / 1050 (conventional electro-pneumatic), YT-1200 (compact), YT-3300 (smart HART), YT-2500 / 2600 (explosion protected)
Product typeElectro-pneumatic valve positioner / smart valve positioner (converts a current signal into a pneumatic pressure output)
Input signal4-20 mA DC (conventional); HART overlay on smart versions
Supply air0.14-0.7 MPa (1.4-7 bar, approx. 20-100 psi)
Travel range10-150 mm linear; 0-90 degree rotary (55-100 degrees on some versions)
Ingress protectionYT-1000: IP66 / Type 4X (FM); YT-1050: IP66
Source documentYTC YT-1000 / 1050 Product Manual (Product Manual Eng ver1.07)

The YT-1000 uses an aluminum housing and the YT-1050 a 316 stainless housing; both come in linear and rotary, single-acting and double-acting versions, with cam adjustment for linearization and outstanding vibration resistance, and are widely used for general process control in chemical, paper and power plants. Selection must fix four items at once: housing material, motion type, acting type and Ex approval, not just the model prefix.

Source: YTC official YT-1000 / 1050 Product Manual (http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf). Brand and parameters are subject to the latest official catalog.

Digital valve positioner appearance reference
Digital valve positioner appearance reference only, not an actual YTC unit; refer to the official catalog

II. Series Split and Selection Positioning

The following data was obtained via online search. Sources: YTC YT-1000 / 1050 Product Manual (http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf); YTC positioner technical guide (https://www.kinkoflow.com/industry-news/ytc-valve-positioners-the-ultimate-technical-user-guide; smart and compact data comes from this online technical source and is subject to the official catalog).

SeriesTypeSignal / protocolTypical service
YT-1000Conventional electro-pneumatic, aluminum housing4-20 mA DC, split range availableGeneral process control in chemical, paper and power plants
YT-1050Conventional electro-pneumatic, 316 stainless housing4-20 mA DC, split range availableService with higher corrosion-resistance needs
YT-1200Compact, for small-bore / rack-and-pinion actuators4-20 mA DC, direct / reverse actionOEM skid packages, compact valve assemblies
YT-3300Smart, with diagnostics and configuration4-20 mA DC + HART 7.0, two-wireCritical loops needing valve signature, friction calculation and predictive maintenance
YT-2500 / 2600Explosion-protected4-20 mA DC; Ex ia / Ex d approvalsHazardous areas in oil and gas and petrochemical plants

The YT-1000 is the most widely installed conventional series; the YT-3300 represents the smart HART route, supporting valve signature analysis and friction calculation with lower steady air consumption than analog models; the YT-2500 / 2600 targets Zone 0 / Zone 1 hazardous areas. Smart and compact data comes from an online technical source and serves only as a selection reference; verify against the official YTC catalog before ordering.

The above data was obtained via online search. Sources: https://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf, https://www.kinkoflow.com/industry-news/ytc-valve-positioners-the-ultimate-technical-user-guide. Non-official data is subject to the official catalog.

III. YT-1000 / 1050 Core Technical Data

The following data was obtained via online search. Source: YTC YT-1000 / 1050 Product Manual (http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf).

ParameterYT-1000 (aluminum)YT-1050 (316 stainless)
Housing materialAluminumStainless steel 316
Motion typeLinear / rotaryLinear / rotary
Acting typeSingle / doubleSingle / double
Input signal4-20 mA DC4-20 mA DC
Supply pressure0.14-0.7 MPa (1.4-7 bar)0.14-0.7 MPa (1.4-7 bar)
Stroke range10-150 mm linear; 0-90 degree rotary10-150 mm linear; 0-90 degree rotary
ImpedanceMax. 250 +/- 15 ohmMax. 250 +/- 15 ohm
Air / gauge connectionPT (G or NPT) 1/4; PT or NPT 1/8NPT 1/4; NPT 1/8
Conduit entryG(PF) 1/2 or NPT 1/2 or M20 x 1.5PG(PF) 1/2
Ingress protectionIP66, Type 4XIP66
LinearitySingle +/-1% F.S.; double +/-2% F.S.Single +/-1% F.S.; double +/-2% F.S.
Hysteresis / sensitivity / repeatability+/-1% / single +/-0.2%, double +/-0.5% / +/-0.5% F.S.Same as left
Flow capacity / air consumption80 LPM (supply 0.14 MPa); 2.5 LPM at 0.14 MPa idleSame as left
Feedback signal (option)4-20 mA (DC 9-28 V)4-20 mA (DC 9-28 V)
Weight2.7 kg (linear) / 2.8 kg (rotary)5.71 kg

Ambient temperature depends on the version: standard -20 to 70 C, high -20 to 120 C, low -40 to 70 C; the temperature range of an Ex version must be taken from its certificate chapter and must not reuse ordinary-version data. Both linearity and sensitivity of double-acting units are lower than single-acting, so the actual control requirement must be checked during selection.

The above data was obtained via online search. Source: http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf. Test conditions: ambient 20 C, absolute pressure 760 mmHg, humidity 65%; consult the manufacturer for detailed test specifications.

IV. Options

The following data was obtained via online search. Source: YTC YT-1000 / 1050 Product Manual (http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf).

OptionKey dataDescription
SPTM-6V smart position transmitter (external)Input 10-150 mm linear / 0-90 degree rotary, output 4-20 mA DC, supply 9-28 V DC, load no more than (Vs-9)/20 mA (750 ohm at 24 V)Linearity +/-1% F.S., hysteresis +/-0.2%, IP67, weight 1.3 kg
Internal limit switches (L/S)Mechanical 2 x SPDT (OMRON V-165-1A5), AC 250 V 16 A; DC 125 V 0.6 A / 250 V 0.3 A8-point terminal, ambient -25 to 80 C
4-20 mA position feedback4-20 mA (DC 9-28 V)Returns valve position to the control system
Ex approval optionsApplied separately per ATEX / IECEx / KCs / NEPSI / FM / CSA / TIIS / INMETRO / TRCUThe certificate name must be stated on the purchase order

The external SPTM-6V has an aluminum housing and fits both linear and rotary motion; its Ex rating is Ex d IIC T6 (KCs), operating temperature -40 to 85 C (LCD -30 to 85 C) and Ex temperature -40 to 60 C. The positioner and its option certificates must be checked as a set; do not add a certificate to the body without checking the options.

The above data was obtained via online search. Sources: http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf, https://www.restavalve.com/wp-content/uploads/2023/04/YT-1000_1050.pdf. Options are subject to the official ordering catalog.

V. Ex Approvals and the Ex ia / Ex d Distinction

The following data was obtained via online search. Source: YTC YT-1000 / 1050 Product Manual (http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf).

Ex form (excerpt)Marking exampleIssuing body
Non-hazardousOrdinary industrial environment—
Flameproof plus encapsulationEx db mb IIB T5 GbATEX / IECEx / KCs / INMETRO
Flameproof plus encapsulation (IIC)Ex dmb IIC T6 GbNEPSI
Intrinsically safeEx ia IIB T6 GbKCs
Flameproof plus encapsulation (TRCU)1Ex d mb IIB T5 Gb XTRCU
Flameproof (FM / CSA)Ex d m IIB T5FM / CSA

Ex ia intrinsic safety and Ex d flameproof enclosure are two different forms. The YT-1000 / 1050 manual lists both options with different order codes and temperature classes. The exact marking must be specified when ordering (Ex db mb IIB T5 Gb and Ex ia IIB T6 Gb are completely different); if unavailable or uncertain, write "please consult for confirmation" and never invent an approval.

The above data was obtained via online search. Source: http://www.ytc.co.kr/wp-content/uploads/2018/08/YT-1000-1050_Product_Manual_Eng_ver1.07_2018-08-28.pdf. Ex markings are subject to official certificates; Ex ia intrinsic safety is not Ex d flameproof enclosure.

VI. Selection Rules and Common Models

StepItem to confirmSelection point
1Define the seriesGeneral YT-1000; corrosive YT-1050; compact actuator YT-1200; smart HART YT-3300; hazardous area YT-2500 / 2600
2Define motion and acting type10-150 mm linear or 0-90 degree rotary, single or double acting; double-acting linearity per +/-2% F.S.
3Define signal and feedbackBasic 4-20 mA DC; add SPTM-6V or 4-20 mA feedback for position return; smart type for HART
4Define Ex protection and temperatureSelect Ex db mb / Ex dmb / Ex ia / Ex d m by zone, check gas group, temperature class and ambient version
5Define connections and optionsAir 1/4, gauge 1/8, conduit G1/2 / NPT1/2 / M20 x 1.5; check limit switches and feedback module as a set

Selection rules: YTC positioner selection follows "define series, define motion / acting type, define signal and feedback, define Ex protection and temperature, define connections and options". Core red lines: 1. Ex ia intrinsic safety is NOT Ex d flameproof enclosure and must be confirmed against official certificates; 2. the smart YT-3300 and conventional YT-1000 have different roles, and the HART loop and load resistance must be recalculated; 3. Ex cable entries and option certificates must match as a set; 4. specific order codes are subject to the official YTC catalog and are not invented.

Common models: YT-1000 (aluminum conventional), YT-1050 (316 stainless conventional), YT-1200 (compact), YT-3300 (smart HART), YT-2500 / YT-2600 (explosion protected); options include the SPTM-6V smart position transmitter, internal mechanical limit switches (2 x SPDT) and 4-20 mA position feedback.

If you are selecting a positioner for an actuator, or want to decide on the YTC series, single or double acting and the Ex option, please feel free to contact us. We can check the model and order code together against your travel, signal protocol and area certification requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.