| Bifold VBP Series Pneumatic Volume Booster - Technical Data & Selection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-21 13:41:01 | Views: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Bifold VBP series (Bifold Fluidpower, UK, now part of Rotork) is a piston-type pneumatic volume booster that converts a small-flow pilot pressure signal into a 1:1 high-flow output. Its standard body is 316L stainless steel, used to speed up the stroke of large-volume actuators and for fast ESD shutdown. This article covers its technical data, order-code digit structure, selection tables and stainless-steel features, and clarifies the difference between the arrival marking VBP-11-12-V and the official field order. I. Product Positioning
Data obtained via online search. Source: Bifold official datasheet "Bifold Volume Booster & Filter Booster Range" BFD03/8 (bifold.co.uk), Rotork VBP product page (rotork.com). No VBP technical entry is held internally; parameters are subject to the latest official datasheet and nameplate / order.
II. Core Technical Data
Data obtained via online search. Source: Bifold official datasheet BFD03/8, Rotork VBP product page, cross-checked by a distributor digit-decoding page (radward.co.uk). Unlisted approvals and inlet pressure values are subject to the nameplate / official manual. III. Working Principle and Flow CapacityPilot pressure is applied to sensing port P; the main valve opens so high flow passes from inlet 1 to outlet 2. When outlet pressure equals pilot pressure, the valve enters a fully closed static position; if outlet pressure is high the valve exhausts at high flow, and if low the main valve supplies make-up air, maintaining a 1:1 pressure ratio.
ESD fast-closing example: the official selection table takes a 50 L actuator set at 5 bar with upstream above 10 bar; a 1" volume booster opens in about 1.2 s and closes in about 2.5 s at 5 bar, with no extra pilot valve or quick-exhaust valve required. Data obtained via online search. Source: Bifold official datasheet BFD03/8 (Cv tables and ESD selection table); 1-1/2" and 2" sizes are not offered as filter boosters. IV. Order-Code Structure and Arrival MarkingThe official field order is VBP - [port] - [ratio] - [seal] - [option] - [revision]. The arrival marking VBP-11-12-V swaps ratio code 11 with port code 12; the official order form is VBP-12-11-V.
Data obtained via online search. Source: Bifold official datasheet BFD03/8, Rotork VBP product page, distributor digit-decoding page radward.co.uk. The arrival marking versus official order discrepancy must be confirmed by nameplate / order; no other fields are invented. V. Related Models and Selection Table
Data obtained via online search. Source: Bifold official datasheet BFD03/8, radward.co.uk and bifold.su order-code entries. Different port sizes require rechecking flow and ESD times. VI. Selection Guide and Common ModelsSelection guide: First confirm the function: the VBP is a pure pneumatic volume booster that drives a high-flow output from a small pilot signal, speeding up large-volume actuator stroke and ESD closure, without built-in regulating / filtering (the filter booster is a separate form). Then check the code: port 12 = 3/4" NPT, ratio 11 = 1:1, seal V = Viton (-20 to +180 deg C); for extreme cold choose AL fluorosilicone, and for sour gas confirm the Inconel X-750 spring and material compatibility. Match Cv and open / close times to actuator volume and required stroke time (the 3/4" version has a distributor-listed Cv of about 8.50, to be confirmed with the manufacturer); pilot 2-10 bar g, maximum inlet 15 bar g, accuracy +/-5 %, two 1/8" NPT gauge ports. For hazardous areas confirm SIL 3 and other applicable certificates per system design and product certificate; intrinsic safety and flameproof enclosure must not be mixed. Most importantly, the arrival marking VBP-11-12-V does not match the official field order, so confirm port size and ratio by nameplate / order before ordering or purchasing spares. Common models: This arrival: BIFOLD VBP series pneumatic volume booster (316L stainless, arrival marking VBP-11-12-V, indicating per official code 3/4" NPT, 1:1, Viton); the purchase record also lists VBP-12-11-V. The above data comes from online-sourced Bifold official datasheet BFD03/8 and Rotork product page, for selection and spare-part cross-check only, not a guarantee; the discrepancy between arrival marking and official field order is subject to nameplate / order, and unlisted items are not invented. If you are selecting a volume booster for a large-volume actuator, or want to confirm the port size, ratio and seal configuration of the VBP, please feel free to contact us. We can check the model and order code together against your actuator volume, pilot pressure and ESD closing time requirements. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |