The IMI Norgren B38P (Norgren belongs to IMI plc) is a stainless steel high-flow filter regulator combining filtration, pressure reduction and relief in one body. Its stainless body meets NACE MR-0175, maximum flow is 4500 L/min, and it is intended for drilling platforms, nuclear power, coal chemical processing, food and other high-flow severe-duty applications. This article organizes its working principle, technical data and order code structure per the official IMI Precision Engineering B38P data sheet, and distinguishes the two delivered models B38P-244-B1MA and B38P-844-M1MA. The outlet regulation range, which is not listed in the data sheet, is honestly marked "please consult for confirmation". I. Product Positioning
The B38P combines filtration and regulation in one body, suited to actuator air supply where high flow and good air quality are both required. The two delivered models share the same temperature / seal, bracket, filter element and thread configuration, differing only in port size (1/4" vs 1") and drain bowl type (manual short bowl vs manual mid-size bowl). Source: IMI Precision Engineering B38P stainless steel high-flow filter regulator official data sheet; specific configuration is subject to nameplate, order or official manual.
II. Working Principle: Filtration + Pressure Reduction + Relief
Filtration, regulation and relief are completed in one body: air is cleaned first, then a diaphragm-spring-valve feedback mechanism stabilizes outlet pressure, and excess pressure is released through the relief port. Filter rating, drain method and port size should be selected together, since all three affect actual flow and maintenance. Source: IMI Precision Engineering B38P official data sheet; filtration / regulation / relief describe the general working principle of filter regulators, with specific construction and performance subject to the original manual and unavailable items marked "please consult for confirmation". III. Main Technical Data
Source: IMI Precision Engineering B38P official data sheet (port / temperature / bracket / drain / filter / thread codes, 4500 L/min, NACE MR-0175, 17 / 31 bar, accessory part numbers and flow curve conditions) corroborated by public selection data; the outlet regulation range is not listed in the data sheet, so it is marked for confirmation and not invented. IV. Order Code StructureThe B38P order code structure is B38P-[port][temperature][bracket]-[drain][filter]M[thread], where the M between the filter code and the thread code is a fixed placeholder and does not indicate the drain type. The two delivered models are decoded digit by digit below.
Do not confuse the drain code in digit 4 with the placeholder M: in B38P-844-M1MA the first M means manual mid-size bowl drain, while the M between the filter code and the thread code is only a fixed character. Complete order numbers and special options are subject to nameplate, order or official manual. Source: IMI Precision Engineering B38P official data sheet digit code table and public selection data; code meanings are subject to the original manual. V. Comparison of the Two Models and Related Models
Distinguish the two delivered models by port size and drain maintenance method, and do not mix them with B52G / B54G, different filter ratings or different drain configurations. The outlet regulation range is not listed in the data sheet, so please consult for confirmation. Source: IMI Precision Engineering B38P official data sheet and public price / selection data, with port, drain, filter and accessory part numbers corroborated; B52G / B54G parameters are subject to their official data sheets. VI. Selection Guide and Common ModelsSelection guide: First check the order code digit by digit: port (2=1/4", 3=3/8", 4=1/2", 8=1"), temperature / seal (4=NBR -40 to +80 °C, 5=FKM -20 to +80 °C), bracket (2=with, 4=without), drain (A=automatic, B=manual short bowl, M=manual mid-size bowl only for 1/2" and 1"), filter (1=5 µm, 2=25 µm, 3=40 µm, stainless 316), thread (A=NPT, G=ISO G), and note that the M between filter and thread codes is a fixed placeholder. Then check against operating conditions: maximum inlet pressure (31 bar manual drain, 17 bar automatic drain), maximum flow 4500 L/min, NACE MR-0175 material requirement and matching pressure gauge range; the outlet regulation range is not listed in the data sheet, so please consult for confirmation or rely on nameplate / order. The two delivered models differ only in port size and drain bowl type; distinguish them by piping and maintenance method and do not mix with B52G / B54G or 25 µm configurations. Common models: IMI Norgren stainless filter regulators B38P-244-B1MA (1/4" NPT, manual short bowl) and B38P-844-M1MA (1" NPT, manual mid-size bowl), both -40 to +80 °C NBR, no bracket, 5 µm stainless 316 element; related configurations include B38P-244-B2MA, B38P-444-M1MA and B38P-844-A1MA. Data comes from the IMI B38P official data sheet and is for selection and spare-part reference only, not guaranteed values; the outlet regulation range is subject to nameplate / order or official manual and is not invented. If you are selecting a filter regulator for actuator air supply, want to decide the B38P port size, filter rating and drain bowl type, or want to verify the pressure limits for manual versus automatic drain, please feel free to contact us. We can check the model and order code together against your air quality, port size and maintenance method. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||