ASCO (now an Emerson brand) series 531 and 325 are two solenoid valve families with very different positioning: the 531 is a European pilot-operated spool valve, 3/2 and 5/2, with an aluminum body and NAMUR direct mount, driven by pilot differential pressure; the 325 is a compact direct-acting valve, 3/2, with a brass body operating from zero differential. This article covers the operating principles, technical data and order codes of both, and compares their Ex options and applications, with sources cited item by item and no invented data.

I. Positioning and Differences

DimensionASCO 531 seriesASCO 325 series
Delivered modelSCG531C001MS 24DCSCXG325B006.24/50-60.22355
ActionPilot-operated spool valve, driven by pilot differential pressureDirect acting, zero minimum working pressure
Ports3/2 and 5/2, 15/16" spool, single / double solenoid3/2 (distributor page marked 3/2 NC)
Body materialAluminum, black anodized (version C); version H is 316L Ex versionBrass (stainless body version optional)
Connection1/4" NAMUR direct mount + G(BSPP) thread1/8" (DN5) G ISO228/1-BSPP thread
FlowKv 0.95 m3/hSeries Kv 0.04 to 0.2 and below 0.04
Typical applicationsActuator control, NAMUR direct-mount manifolds, process controlCompact pneumatic control in packaging, analysis and diagnostic equipment
SourceASCO Series 531 official selection catalogEmerson official 325 product page and distributor model pages (web verified)

The most common confusion is the body material: the 531 body is aluminum (black anodized), not brass or stainless. Brass bodies are typical of the 210 general-purpose 2/2 pilot series and the 325 compact direct-acting series, while 316 stainless bodies appear in the 327 / 8327 direct-acting series. Do not assign "brass / stainless body" to the 531.

Source: ASCO Series 531 official selection catalog; 325 series data obtained via web search from the Emerson official ASCO Series 325 product page https://www.emerson.com/en-us/catalog/asco-325 and distributor model pages, cited in the sections below. Parameters are subject to the official data sheet / nameplate.

ASCO SCG531 solenoid valve
ASCO SCG531 product photo, for selection reference only

II. 531 Working Principle (Pilot Spool)

The 531 is a pilot spool valve: the solenoid pilot stage first switches the air path of the control chamber, and the medium differential pressure then moves the main spool to change the port connections for 3/2 or 5/2 switching. Single-solenoid versions return by spring and double-solenoid versions are bistable. Because it relies on differential pressure, the standard configuration needs 2 to 10 bar working differential; fitting an external pilot supply by reversing the gasket gives zero minimum operating pressure.

StageActionNotes
Pilot switchingThe coil actuates the pilot spool and changes the control chamber air pathLow-power coil, SC prefix approx. 2 to 3W
Differential moves main spoolControl chamber differential shifts the 15/16" main spoolStandard requirement 2 to 10 bar differential
Switching outputPort connections change for 3/2 or 5/2 switchingFunction code sets the port group; 001 is NAMUR 3/2 NC
Reset / holdSingle solenoid spring return, double solenoid bistableMS operator for manual override during power loss or commissioning
External pilot optionReverse gasket and connect external pilot supply (TPL20547, prefix X)Achieves zero minimum operating pressure

The 531 offers both NAMUR direct mount and threaded mounting: the 1/4" NAMUR direct mount comes with two interface plates (position A1 for 3/2 NC and A2 for 5/2), and the external pilot port is a 1/8" pipe thread. Media are air, inert gas and filtered gas.

Source: ASCO Series 531 official selection catalog (pilot construction, 3/2 and 5/2, 15/16" spool, NAMUR mounting, external pilot TPL20547 and 2 to 10 bar differential).

III. 531 Data and Order Code

ItemValue (SCG531C001MS 24DC)
Code decodingSC (epoxy molded coil, non-hazardous IP65, EN 60730, spade connector, BP basic power) + G (ISO G/BSPP thread) + 531 (European pilot spool series) + C (version C) + 001 (NAMUR 3/2 NC, single solenoid) + MS (push-pull / screw lock manual operator) + 24DC (24V DC coil)
Construction / ports3/2 and 5/2, 15/16" pilot spool, single-solenoid spring return or double-solenoid bistable
Body materialAluminum, black anodized (version C), not brass / stainless; version H is 316L Ex version
Connection / mounting1/4" NAMUR direct mount + G(BSPP) thread; two NAMUR interface plates; external pilot port 1/8"
FlowKv 0.95 m3/h (approx. 1100 l/min ANR); Cv not listed by the manufacturer, nothing invented
Working differential2 to 10 bar; external pilot (TPL20547, prefix X) gives zero minimum operating pressure
Media / temperatureAir, inert gas, filtered gas; -25 to +60 C (SC prefix)
Seal / internalsNBR + PUR; moving parts Zamak / stainless / POM / aluminum, end caps and adapter plates glass-filled PA
Coil / powerSC prefix BP basic power, low power approx. 2 to 3W; 24V DC; spade connector
Ex formsSC = non-hazardous IP65; JPIS = Ex ia IIC T6 (Pi no more than 1.5W, barrier required); LPKF = Ex d IIB+H2 T4 to T6; EF/VCEFCM = Ex mb / Ex dmb encapsulation

The exact port group of function code 001 is not fully listed in the compact material and is subject to the ASCO 531 official catalog; when the port is 8 = NPT the series number is written 8531. Ex ia intrinsic safety is NOT Ex d flameproof enclosure and they must not be interchanged.

Source: ASCO Series 531 official selection catalog (preferred model details 2.2, code tables, prefix electrical characteristics and materials); exact ports of function code 001 and Cv are subject to the official catalog, nothing invented.

IV. 325 Working Principle (Direct Acting)

The 325 is a compact direct-acting valve: when energized the coil directly drives the armature to open the orifice, so it operates from zero differential pressure; the internal parts are removable for cleaning, it can be manifold-rail mounted and installed in any orientation, suiting compact pneumatic control on small equipment.

StageActionNotes
Energized openingThe coil directly drives the armature and opens the orificeDirect acting, zero minimum working pressure
Switching outputCompletes 3/2 switching (Universal / NC)Specific port function subject to official data sheet / nameplate
ResetSpring returns on de-energizationSingle solenoid, spring return
Mounting / serviceManifold rail mounting, any orientation, internal parts removable for cleaningCompact construction for equipment integration

Data obtained via web search. Source: Emerson official ASCO Series 325 product page https://www.emerson.com/en-us/catalog/asco-325 (series construction, direct acting, brass / stainless bodies, media and mounting features); Kempston Controls and KSCdirect model pages (3/2 NC, 1/8" DN5, orifice 1.6mm). Web data is not a written official guarantee; specific specifications are subject to the official data sheet / nameplate.

Data obtained via web search. Source: https://www.emerson.com/en-us/catalog/asco-325 ; https://www.kempstoncontrols.com/SCXG325B006-24-DC-22355/Emerson-Asco/sku/963734 ; https://kscdirect.com/itemDetail/9446465/scxg325b006-24-50-60-tpl22355-complete-sol-valve-valve-so .

V. 325 Data and Order Code

ItemValue (SCXG325B006.24/50-60.22355)
Series / action325 compact solenoid valve, direct acting, zero minimum working pressure, manifold rail mounting
Ports / function3/2 (Universal / NC, distributor page marked 3/2 NC); port function subject to official data sheet
Body materialBrass, with stainless body version optional
Size / connection1/8" (DN5), G ISO228/1-BSPP pipe thread; distributor page lists orifice 1.6mm
Voltage / frequency24V AC, 50-60Hz (.24/50-60); series standard voltages also include 24 DC / 115 AC / 230 AC
PressureVacuum to 150 psig (approx. 10.3 bar) at the 325 series level; specific differential subject to official data sheet
Flow Cv / KvSeries Kv 0.04 to 0.2 and below 0.04; specific value for construction 006 not published, please consult for confirmation
Seal materialDistributor page lists brass with resilient seal; specific elastomer not published, please consult for confirmation
ExSeries can offer hazardous area versions per ATEX / CENELEC; this SCX prefix is SC standard coil (IP65 non-hazardous) + X special construction, Ex status unclear, please consult for confirmation
Standards / approvalsEmerson official page lists CSA, UL and Type 1/2/3/3S/4/4X/6/6P/7/9
MediaAir, inert gas, light oil, water; temperature range subject to official data sheet
Order codeSCX (SC standard coil + X special construction, requires TPL) / G (G thread BSPP) / 325 (series) / B (version) / 006 (construction: 1/8" DN5, orifice 1.6) / .24/50-60 (24V AC 50-60Hz) / .22355 (TPL22355 parts list)

The suffix .22355 is the temporary parts list number TPL22355 and must be checked together when ordering; .24/50-60 differs from the same-construction .24/DC (24V DC) version only in voltage / frequency and must not be confused. Some digit definitions after G are not published by the manufacturer and require confirmation.

Data obtained via web search. Source: Emerson official ASCO Series 325 product page https://www.emerson.com/en-us/catalog/asco-325 ; Kempston Controls https://www.kempstoncontrols.com/SCXG325B006-24-DC-22355/Emerson-Asco/sku/963734 ; KSCdirect https://kscdirect.com/itemDetail/9446465/scxg325b006-24-50-60-tpl22355-complete-sol-valve-valve-so . Unlisted items are not invented.

VI. Ex Differences and Application Comparison

Both series have hazardous and non-hazardous versions but use different prefix systems. Ex ia intrinsic safety and Ex d flameproof enclosure are two different protection forms; if data cannot be found write "please consult for confirmation" and never interchange them.

Dimension531 series325 series
Prefix of this modelSC = epoxy molded coil, non-hazardous IP65, EN 60730SCX = SC standard coil (IP65 non-hazardous) + X special construction
Intrinsic safety optionJPIS = Ex ia IIC T6 (Pi up to 1.5W, 24VDC only, barrier required, air / inert gas only)Series can offer hazardous area versions per ATEX / CENELEC; specific prefix requires confirmation
Flameproof optionLPKF = Ex d IIB+H2 T4 to T6 (2W, low temperature); EF/VCEFCM = Ex mb / Ex dmb encapsulation (CCC Ex)Please consult for confirmation; not to be mixed with the Ex ia / Ex d of the 8327
ApplicationsActuator control, NAMUR direct-mount manifolds, 3/2 and 5/2 switching in process controlCompact air / inert gas / light oil / water control in packaging, analysis and diagnostic equipment
MountingNAMUR direct mount + G thread, external pilot for zero minimum differentialCompact direct acting, manifold rail mounting, any orientation, cleanable internals

The 531 excels in NAMUR direct mounting and 5/2 switching for pneumatic circuits with actuators; the 325 excels in compactness, zero-differential direct action and multi-media compatibility for equipment integration. When intrinsic safety or flameproof enclosure is required, the 531 has a defined prefix system (JPIS / LPKF), while the Ex status of the 325 must be confirmed order by order.

Source: ASCO Series 531 official selection catalog; web sources for the 325 series are listed in section V. Ex ia and Ex d are strictly distinguished.

VII. Selection Guide and Common Models

Selection guide: First define action and ports: choose the 531 when a pilot 3/2 or 5/2 spool valve, NAMUR direct mount + G(BSPP), Kv 0.95 and 2 to 10 bar differential are needed; choose the 325 when a compact direct-acting 3/2 valve, zero differential, 1/8" G and small flow are needed. Then check body material (531 aluminum, 325 brass), connection, voltage (this 531 model 24V DC, this 325 model 24V AC 50-60Hz), flow and media. For Ex: 531 uses SC for non-hazardous, JPIS for intrinsic safety (barrier required), LPKF for flameproof and EF/VCEFCM for encapsulation; the Ex status of the 325 requires confirmation. Red lines: 1. Ex ia is NOT Ex d and they must not be interchanged; 2. the 531 aluminum body and the 325 brass body are not interchangeable, and brass / stainless bodies do not apply to the 531; 3. the .22355 of the 325 is a TPL parts list number and must be checked together; 4. unpublished items such as exact ports of code 001, Cv / Kv of construction 006 and seal material require confirmation, and nothing is invented.

Common models: 531 series SCG531C001MS 24DC (delivered, non-hazardous SC version, aluminum body, Kv 0.95), plus SCG531C017MS 24VDC, SCG531C001MS 230VAC, VCEFCM8531G301MO 24DC (flameproof encapsulated) and JPIS8531B301MO 24DC (intrinsically safe complete valve); 325 series SCXG325B006.24/50-60.22355 (delivered, brass, 24V AC) and SCXG325B006.24/DC.22355 (24V DC version).

If you are selecting a solenoid valve for a pneumatic circuit, want to decide between the pilot-operated 531 and the direct-acting 325, between an aluminum and a brass body, or between intrinsic safety and flameproof enclosure, or want to verify an order code and TPL parts list number, please feel free to contact us. We can check the model and specification together against your media, differential, mounting interface and area certification.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.