Home » Service & Support » Technical Documentation
ASCO Series 8327 Solenoid Valves - Technical Data & Selection
Release time:2026-11-21 13:41:01 | Views:

ASCO (now an Emerson brand) series 8327 is a direct-acting 3/2 balanced poppet solenoid valve with a one-piece 316L stainless body that operates at zero differential pressure, widely used for on/off control of air and inert gas. Centered on the delivered model WSNFTIS8327B312 24DC, this article covers the working principle, core technical data, digit-by-digit order code decoding, the strict distinction between Ex ia intrinsic safety and Ex d flameproof enclosure, and differences among related models, with official catalog sources cited item by item.

I. Product Positioning

ItemDescription
BrandASCO (an Emerson brand; ASCO now belongs to Emerson)
Series8327 series (European designation 327; series number rewritten from 327 to 8327, sharing basic numbers such as 327B312)
Delivered modelWSNFTIS8327B312 24DC
Product typeDirect-acting balanced poppet valve, 3/2, single solenoid, for on/off control
Body materialOne-piece 316L stainless steel body (last digit of basic number 2 = 316L stainless, 1 = brass)
Ex formThis model has the WSNFTIS prefix = Ex ia IIC T6 Gb intrinsic safety; not the Ex d flameproof WSNF / NF prefix
Main documentASCO official Series 327 catalog, document 80020GB-2018/R01 (2018 edition)

The 8327 is direct acting rather than pilot operated: the solenoid directly lifts the poppet, so there is no minimum working pressure requirement and it switches reliably at zero differential pressure. Note that the standard function of the 8327 is 3/2; if a 4/2 or 5/2 spool function is needed on site, move to a pilot spool series such as the 531 rather than describing the 8327 as a four-way valve, subject to the official catalog.

Source: ASCO official Series 327 catalog (80020GB-2018/R01, 2018 edition) sections 4.3, 4.3.1 and 4.4, prefix table, electrical characteristics table and basic number decoding table. Parameters are subject to the latest official catalog.

ASCO 8327B312 stainless solenoid valve
ASCO 8327B312 product photo, for selection reference only

II. Working Principle and Construction

The key of the direct-acting balanced poppet valve is that it does not rely on differential pressure: when energized, the coil directly drives the armature and lifts the poppet off its seat, changing the connection between the three ports for 3/2 switching; on de-energization a spring returns it. The balanced construction largely cancels the axial force of the medium on the poppet, so it operates from vacuum / zero differential pressure up to the rated upper limit.

StageActionNotes
De-energizedThe spring presses the poppet onto the seat, ports remain in the normal positionSpecific NO / NC function is subject to the basic number and official catalog
EnergizedThe coil directly lifts the armature and poppet, switching port connectionsDirect acting, no pilot orifice, operates at zero differential pressure
Balanced constructionAxial forces of the medium on the poppet largely cancelReduces required solenoid force and widens usable pressure range
ResetOn de-energization the spring returns the poppet to the normal positionSingle solenoid, spring return
Intrinsic limitLow-power IS coil requires a safety barrierAir and inert gas only

The 327 / 8327 series is certified to IEC 61508 functional safety with SIL 3 capability (TUV and Exida), but a dedicated exhaust protector is required in a SIL loop; versions with MO / MS manual operators are excluded from the SIL certification scope and must be checked separately.

Source: ASCO official Series 327 catalog (80020GB-2018/R01), operating principle, zero differential pressure and SIL 3 specific rules.

III. Core Technical Data

ParameterValue (delivered model WSNFTIS8327B312 24DC)
Series and action8327 direct-acting balanced poppet, 3/2, single solenoid
Ports / function3/2, on/off control; no minimum working pressure
Body materialOne-piece 316L stainless steel (last digit of basic number 2)
Coils and ExWSNFTIS = 316L stainless intrinsically safe enclosure, Ex ia IIC T6 Gb / II2D Ex tb IIC Db, IP66/67; IS coil 0.5W DC
PowerIntrinsically safe type 0.5W (24V DC only); power digit 3 is the LP tier, and the IS prefix is rated at IS 0.5W rather than LP 1.85W
Voltage24V DC (marked 24DC); intrinsically safe type is DC only
Port connection1/4" NPT
Cable entry1/2" NPT thread (T variant, no cable gland supplied)
FlowCv 0.49 (port 1 to 2) / 0.56 (port 2 to 3); Kv 0.42 / 0.48
Seal and temperatureBasic number seal digit 1 = (F)VMQ low-temperature seal; 327B312 minimum fluid temperature approx. -60 C (subject to official catalog)
MediaAir, inert gas; intrinsic safety type limited to these two media
Ingress protectionIP66 / IP67
Functional safetyIEC 61508, SIL 3 capability (TUV and Exida); exhaust protector required, MO / MS versions excluded

Flow Cv / Kv and minimum temperature are given at the 8327 series level; specific port functions and temperature ratings are subject to the 327 official catalog. Items not listed by the manufacturer are not invented and are subject to the nameplate / order or official manual.

Source: ASCO official Series 327 catalog (80020GB-2018/R01) sections 4.3 / 4.3.1 / 4.4, electrical characteristics table, complete basic number decoding table, cable entry table and SIL 3 rules.

IV. Order Code Decoding

Taking the delivered model WSNFTIS8327B312 24DC as an example, the order code is decoded group by group as prefix / series / basic number / voltage:

Code segmentMeaningNotes
WSNFTISIntrinsically safe 316L stainless enclosure + T variantEx ia IIC T6 Gb, II2D Ex tb IIC Db, IP66/67; IS coil 0.5W DC; T = 1/2" NPT threaded entry with no cable gland
8327Direct-acting 3/2 seriesUS series number for the European 327 designation
BBasic flow versionOrifice 5.7mm in the 327 basic number
3LP low-power digitIS prefix is rated at IS 0.5W rather than LP 1.85W
1(F)VMQ low-temperature sealBasic number seal digit
2316L stainless bodyLast digit 1 is brass; verify digit by digit
24DC24V DC coilIntrinsically safe type is DC only

The TIS in the model indicates an original-factory variant of the WSNFIS intrinsically safe 316L family; the near model WSNFIS8327B312 24VDC in procurement records corroborates it. The complete order configuration is subject to the nameplate / order. The last digit of the basic number determines the body material and is the most easily misread digit in selection.

Source: ASCO official Series 327 catalog (80020GB-2018/R01) sections 4.3 and 4.4, prefix table and basic number decoding table; the order / nameplate is the final authority.

V. Ex Options: Ex ia is NOT Ex d

Intrinsic safety and flameproof enclosure are two different protection principles: intrinsic safety limits circuit energy and requires a certified safety barrier, while flameproof enclosure relies on a robust housing to contain an internal explosion and prevent flame transmission. Both versions exist in the 8327 series, strictly distinguished by prefix and never to be interchanged.

Prefix / versionEx formPower / coilConstraint
WSNFTIS / WSNFIS (this model)Ex ia IIC T6 Gb, II2D Ex tb IIC Db, IP66/67, 316L stainless enclosureIS coil 0.5W DCCertified safety barrier required; air and inert gas only
WSNF8327B102 / B112Ex d flameproof (Ex db IIC Gb), 316L stainless bodyRP power approx. 3.6 to 3.7WFPM / VMQ seals; not interchangeable with intrinsic safety type
NF8327B112 24VDCFlameproof (Ex d), 316L body + aluminum flameproof coil housing24V DCVMQ low-temperature seal approx. -40 C; differs from the intrinsic 316L enclosure
WSJE8327B102MOWith MO manual operator-MO / MS operator versions excluded from SIL certification

Ex ia intrinsic safety is NOT Ex d flameproof enclosure: their certificates, wiring and safety barrier requirements all differ. First confirm the loop attribute (intrinsic or flameproof) and then check the prefix and certificate. If a certificate number, temperature class or applicable zone cannot be found, write "please consult for confirmation" and rely on the official catalog and certificates.

Source: ASCO official Series 327 catalog (80020GB-2018/R01), prefix table, electrical characteristics and Ex marking table. Ex ia and Ex d are strictly distinguished.

VI. Related Models and Series Differences

Model / seriesKey featureDifference from this model
WSNFIS8327B312 24VDCNear model of the WSNFIS intrinsic 316L familySame family as the delivered model; T is the factory variant, differences subject to the 327 catalog
ASCO 327 (European direct acting)Shares basic numbers such as 327B312 with 8327European designation with optional G thread; media and temperature subject to official catalog
ASCO 531 seriesPilot spool valve, 3/2 and 5/2Pilot operated, aluminum body, Kv 0.95; differs from the 8327 direct-acting 3/2
ASCO 325 seriesCompact direct-acting 3/2, brass body, 1/8" GBrass body and smaller port; differs from the 8327 316L and 1/4" NPT
ASCO 210 series2/2 pilot diaphragm valve, Rp 3/4", Kv 5.7Pilot operated 2/2 requiring minimum differential; different application

Do not substitute models just because they are all "3/2 direct acting": body material (last digit 1 brass / 2 stainless), port connection (1/4" NPT versus 1/8" G), Ex prefix and flow rating must all be checked item by item.

Source: ASCO official Series 327 catalog (80020GB-2018/R01); features of the 531 / 325 / 210 series are based on their respective official selection catalogs, and parameters must not be mixed.

VII. Selection Guide and Common Models

Selection guide: 8327 selection follows the sequence "confirm loop attribute (Ex ia intrinsic or Ex d flameproof), confirm 3/2 direct-acting zero-differential function, check body material (last digit of basic number 2 for 316L and 1 for brass) and connections (port 1/4" NPT, cable entry 1/2" NPT), verify 24V DC, power at IS 0.5W, Cv 0.49/0.56 and (F)VMQ low-temperature seal, and if used in a SIL loop fit an exhaust protector and avoid MO / MS versions". Core red lines: 1. Ex ia is NOT Ex d, this model WSNFTIS is intrinsic while WSNF / NF are flameproof and must not be interchanged; 2. the 8327 is a direct-acting 3/2 valve, not a four-way or five-way spool valve, and 4/2 or 5/2 requirements should move to a series such as the 531; 3. the intrinsic safety type is limited to air and inert gas and requires a safety barrier; 4. unlisted items are subject to the nameplate / order or official manual and nothing is invented.

Common models: delivered ASCO (Emerson) stainless solenoid valve WSNFTIS8327B312 24DC, an 8327 intrinsically safe direct-acting 3/2 valve with a 316L stainless body and 24V DC; related models include WSNFIS8327B312 24VDC, WSNF8327B102 / B112 (Ex d), NF8327B112 24VDC, WSJE8327B102MO (with MO) and the European 327.

If you are selecting a 3/2 solenoid valve for a pneumatic circuit, want to decide between intrinsic safety and flameproof enclosure or between a 316L and brass body, or want to verify an order code and safety barrier configuration, please feel free to contact us. We can check the model and specification together against your media, differential pressure, area certification and SIL requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.