Home » Service & Support » Technical Documentation
SAMSON 3730-4 Model Code Decoding (PROFIBUS-PA Version)
Release time:2026-11-21 02:05:02 | Views:

The SAMSON 3730-4 is the PROFIBUS-PA fieldbus model in the 3730 series of smart electropneumatic positioners (not HART; the HART model is the 3730-3). It uses a 16-digit order code in which the 4th digit is fixed at 0 as the PROFIBUS bus identifier, the key coding difference from the 3730-3 / 3730-5. This article decodes the 3730-4 order code position by position and explains the meaning and options of each digit. The complete code is subject to the result generated by the SAMSON official selection / ordering tool.

I. Product Positioning

ItemDescription
BrandSAMSON
Model3730-4 smart electropneumatic positioner
CommunicationPROFIBUS-PA fieldbus (not HART; HART is the 3730-3, FF is the 3730-5)
Control principleAnalog PD control plus microprocessor (hybrid technology platform)
Hazardous areaMainly intrinsically safe Ex ia, with Ex nA non-incendive; no Ex d in the 3730-0-5
Order code16 digits, with the 4th digit fixed at 0 (PROFIBUS bus identifier)
Main data sheetSAMSON T 8384-4 EN (Type 3730-4, PROFIBUS-PA), master data sheet NA 0122

The 3730-4 is designed for PROFIBUS-PA fieldbus applications; the positioner is bus-powered and connected to the process control system. It shares the same 16-digit count as the 3730-3 (HART) and 3730-5 (FF), but the explosion protection coding method and dedicated option sets differ, so the digit tables are not interchangeable. The 4th digit of both the 3730-4 and 3730-5 is fixed at 0 as the bus identifier; for the 3730-4 explosion protection occupies a single digit (P1), while for the 3730-5 it occupies four digits (P1 + P14-P16).

Source: SAMSON official data sheets T 8384-4 EN and NA 0122; coding organized from the official data sheet digit rules. Parameters are subject to the latest official data sheet.

SAMSON 3730-4 smart electropneumatic positioner
Official product image, for selection reference only

II. Order Code Overall Structure

A complete order number is "3730-4" followed by 16 digits, in a "grouped by position" structure: the first digit is explosion protection, and each subsequent digit or group corresponds to one option. The mask example for the 3730-4 is: x x x 0 x 0 x x 0 x 0 0 x 0 0 0. The 4th digit is fixed at 0 and is the bus identifier for the PROFIBUS-PA model; no other digit may be entered there. This is the key digit distinguishing the 3730-4 from the 3730-3 / 3730-5.

Note in particular that explosion protection for the 3730-4 occupies only digit P1, with options 0 (none), 1 (ATEX intrinsically safe Ex ia), 3 (CSA/FM intrinsically safe / non-incendive) and 8 (ATEX Ex nA non-incendive). This is close to but not identical with the 3730-3 option set (P1, including ATEX / CSA / dust / Ex nA), and differs more from the 3730-5 (four digits for explosion protection). Inferred digit positions should be confirmed with the official ordering tool.

Source: SAMSON official data sheet T 8384-4 EN; digit structure organized from the official data sheet. Inferred digit positions are subject to confirmation with the official ordering tool.

III. Position-by-Position Code Breakdown

PositionOptionCode and meaning
P1Explosion protection0 none; 1 ATEX II 2G EEx ia IIC T6 / II 2D IP65 T80 C; 3 CSA/FM intrinsically safe / non-incendive; 8 ATEX II 3G EEx nA II T6
P2Inductive position switch0 none; 1 1x SJ2-SN type
P3Solenoid valve0 none; 4 with 24 V DC
P4Bus identifier (fixed)Fixed at 0, PROFIBUS-PA identifier
P4-P8*Remote position sensor0 none; 00100 with
P5-P6*Digital input00 none; 01 floating contact
P7Self diagnostics1 EXPERT (standard); 2 EXPERT+ (enhanced)
P9-P10*Housing material0 aluminum (standard); 01 stainless steel 1.4581
P12Special application0 none; 1 specified paint coating; 2 vent connection with 1/4-18 NPT thread
P?*Special version000 none; 1000099 NEPSI Ex ia; 8001100 NEPSI Ex nL/nA; 1001122 IECEx

Positions marked with * are organized from the official tables; verify them with the official ordering tool when filling in. Because P4 is used as the fixed PROFIBUS bus identifier, the position numbers of options such as the remote position sensor and digital input are not fully identical with those of the 3730-3, so the 3730-3 digit table cannot be copied over. The complete code is subject to the result generated by the SAMSON official selection / ordering tool.

Source: SAMSON official data sheet T 8384-4 EN and ordering rule organization; positions marked * are subject to confirmation with the official ordering tool and are not invented here.

IV. Confusion Points and Verification

1. The 3730-4 is PROFIBUS-PA, not HART: the HART model is the 3730-3; entering HART communication parameters for a 3730-4 causes configuration errors. 2. The 4th digit is fixed at 0: this is the bus identifier and cannot take another digit; the 3730-3 has no such mandatory position. 3. Different explosion protection digit counts: the 3730-4 uses only P1 while the 3730-5 uses four digits; the digit tables are not interchangeable. 4. Distinguish from the 3731: the 3731 series (3731-3 HART / 3731-5 FF) is the flameproof Ex d version with an ordering code based on T 8387 and a different digit count from the 3730; there is no Ex d in the 3730-0-5. 5. Distinguish from the 3730-6: the 3730-6 is a special design with pressure monitoring (14-digit code, T 8384-6 EN), not the 3730-4 coding system. 6. Refer to the official tool: for any doubtful digit, rely on the output of the official selection / ordering tool.

When selecting on site, first confirm the fieldbus protocol (PROFIBUS-PA), then fill in the P1 explosion protection code by area certification, add options such as position switch, solenoid valve, remote position sensor and digital input in the corresponding positions as needed, and finally verify the complete 16-digit code. For certifications or options that cannot be found, write "please consult for confirmation" and do not invent them.

Source: SAMSON official data sheets T 8384-3/4/5 EN, T 8384-6 EN and T 8387-3/5 EN; similar models are distinguished one by one, with sources subject to the official data sheets.

V. Selection Guide & Common Models

Selection guide: Selection of the 3730-4 follows the sequence "define communication (PROFIBUS-PA), define explosion protection (P1), add options, verify the 16-digit code". Always remember that the 3730-4 is the PROFIBUS-PA type rather than HART, the 4th digit is fixed at 0 as the bus identifier, and explosion protection occupies only P1. For specific digit positions, certification options and suffixes, refer to the SAMSON official selection / ordering tool and data sheet T 8384-4 EN; when unavailable, write "subject to the official manual" and do not invent an order code.

Common models: the 3730-4 (PROFIBUS-PA, the subject of this article); related models include the 3730-3 (HART, widely used), 3730-5 (FF), 3730-0/1/2 (non-communication basic versions), 3730-6 (pressure monitoring, 14-digit code) and the flameproof Ex d 3731-3 (HART) / 3731-5 (FF). The models have different digit counts and explosion protection coding methods, so their digit tables are not interchangeable.

If you are specifying a PROFIBUS-PA positioner for a valve, or want to confirm the 3730-4 order code, explosion protection options and bus identifier digit, please feel free to contact us. We can check the model and the 16-digit order code together against your protocol, area certification and option requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.