| Masoneilan Actuator Diaphragms & Spare Parts List (incl. 035104040-716-0000) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-21 02:05:02 | Views: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The diaphragm is a key wear part of a Masoneilan (now part of Baker Hughes, not GE) spring-diaphragm actuator, distinguished by actuator series and size number; diaphragms of different series or size numbers are not interchangeable. This article lists common Masoneilan actuator diaphragm spare part numbers (including 035104040-716-0000), identification methods and verification precautions. The specific fit and rubber material are subject to the official spare parts manual and nameplate. I. Product Positioning
The diaphragm converts the actuator signal pressure into thrust on the pushrod and is the power-conversion element of a spring-diaphragm actuator. After prolonged pressure and repeated deformation it tends to age, crack or leak, making it a common replacement item. Masoneilan diaphragms are distinguished by "actuator series + size number" with one-to-one part numbers; they must not be substituted merely because the appearance or dimensions look similar. Source: Masoneilan official spare part number data. Diaphragm specifications, materials and fit are subject to the official spare parts manual and the actuator nameplate.
II. Diaphragm Spare Part Number Cross-Reference
The table is grouped as "eccentric rotary valve actuator diaphragms to Series 37/38 diaphragms to Series 87/88 diaphragms", with each group ordered by size number (inch size or number) from small to large. Among them, 035104040-716-0000 corresponds to the 4.5-inch eccentric rotary valve actuator diaphragm, a frequently requested part number. This table lists only part numbers and applicable series / sizes, with no prices; the specific material, validity and substitution relationships are subject to the official spare parts manual. Source: Masoneilan official spare part number data. Size numbers and fit are subject to the official spare parts manual; materials or substitute models are not invented here. III. Part Number Identification Method
The middle segment and suffix of a part number usually correspond to the size, material or design version; parts cannot be considered interchangeable just because the prefix matches. For example, different size numbers of Series 37/38 diaphragms correspond to different middle-segment and suffix combinations, and a single wrong digit leads to a wrong spare being shipped. When a fit cannot be found, write "subject to the official spare parts manual" and do not invent it. Source: Masoneilan official spare part number data. The digit-by-digit meaning of part numbers is subject to the official spare parts manual. IV. Replacement and Storage Precautions1. Depressurize and isolate first: before replacing a diaphragm, vent the actuator, isolate the air supply and disconnect the control signal; confirm no residual pressure before removing the diaphragm casing. 2. Record the orientation: mark the relative position and direction of the casing, diaphragm and pushrod before disassembly to avoid reversing or misaligning them on reassembly. 3. Inspect in pairs: diaphragm aging is often accompanied by wear of the casing, spring and pushrod seal; inspect them together so that leaks do not persist after the diaphragm is replaced. 4. Verify the specification: on receipt, recheck the part number against the nameplate for series and size before installation. 5. Storage conditions: store rubber diaphragms away from light and heat and out of contact with oil and sharp objects, following the official storage requirements. 6. Restore and test: tighten the casing to the torque specified in the manual, then supply air gradually and perform travel and leak tests to confirm no leakage or sticking. It should be emphasized that the diaphragm is only one part of the actuator. If a valve shows inaccurate positioning, oscillation or leakage, first determine whether the problem lies in the positioner, air supply or actuator diaphragm, rather than replacing the diaphragm blindly. Specific disassembly steps, tightening torques and test pressures are subject to the official manual. Source: general Masoneilan actuator maintenance requirements. Specific steps, torques and test values are subject to the official manual. V. Selection Guide & Common ModelsSelection guide: diaphragm spare verification follows the sequence "read the nameplate for the series, determine the size number, look up the official part number, check the suffix, confirm the material". 035104040-716-0000 is the 4.5-inch eccentric rotary valve actuator diaphragm; 035106040-716-0000 and 035107040-716-0000 correspond to the 6-inch and 7-inch sizes respectively. Series 37/38 and Series 87/88 diaphragms each have their own part number systems and must not be mixed with eccentric rotary valve diaphragms. All fit relationships and materials are subject to the official spare parts manual and nameplate; when unavailable, write "subject to the official spare parts manual" and do not invent them. Common models: eccentric rotary valve actuator diaphragms 035104040-716-0000 (4.5-inch), 035106040-716-0000 (6-inch) and 035107040-716-0000 (7-inch); Series 37/38 actuator diaphragms 010271018-686-0000 (size 9), 010272034-24250000 (size 11), 010273035-779-0000 (size 13), 010274040-24250000 (size 15) and 010275023-686-0000 (size 18); Series 87/88 actuator diaphragms 010866003-779-0000 (size 16) and 010867003-779-0000 (size 23). If you need to verify the diaphragm model of a Masoneilan actuator, or have a part number and want to confirm the applicable actuator series and size, please feel free to contact us. We can check the spare part number against the nameplate and site conditions to avoid shipping the wrong part. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |

简体中文