Home » Service & Support » Technical Documentation
Masoneilan BR200 Volume Booster - Working Principle & Technical Data
Release time:2026-11-21 02:05:02 | Views:

The Masoneilan BR200 is a high-capacity pneumatic volume booster relay from Masoneilan (now part of Baker Hughes), used to speed up the stroking of large-volume diaphragm or piston actuators. Note that the BR200 is a pneumatic volume booster relay (also called a booster relay), not an air filter regulator; the two are different categories with different functions and must not be confused. Based on the official instruction manual, this article covers its working principle, technical data, air supply requirements and selection points.

I. Product Positioning

ItemDescription
BrandMasoneilan, now part of Baker Hughes
ModelBR200 high-capacity pneumatic volume booster relay
Product categoryVolume booster (booster relay), not an air filter regulator
FunctionAmplifies a small-flow pneumatic signal into a high-flow output to speed up actuator travel, with an approximately 1:1 output
Applicable actuatorsDiaphragm or piston pneumatic actuators
Main manual"BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014)

The BR200 and BR400 belong to the same Masoneilan high-capacity volume booster family: the BR200 has a smaller port (lower Cv, 1/4 in connection) and the BR400 has a larger flow capacity (1/2 in connection). They are used on control valves with demanding stroking-time requirements or large actuator volumes, working with positioners to reduce response delay. A volume booster is a purely pneumatic accessory with no electrical body; it must be clearly distinguished from regulators, lock-up valves and other functional accessories.

Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014). Product category and parameters are subject to the official manual.

Masoneilan product reference
Masoneilan product image, for selection reference only

II. Working Principle

The BR200 uses a diaphragm force-balance 1:1 amplification principle, working as follows:

StepProcess
1. Signal inputThe input signal pressure from the positioner acts on the upper diaphragm, producing a downward force
2. Force-balance comparisonOutput pressure acts on the lower diaphragm through the seal plate orifice; upper and lower diaphragm forces are compared at about 1:1
3. Supply amplificationAs the input signal rises, the upper diaphragm is pushed down, opening the pilot valve and admitting high-flow supply to the output until the lower diaphragm force rebalances
4. Exhaust depressurizationAs the input signal falls, the exhaust valve opens and output pressure falls back to equal the input
5. Bypass stabilizationAn internal bypass valve with a lock screw routes part of the input signal directly to the output for stable control under small or slowly changing signals

Because output pressure follows input pressure at 1:1 while flow capacity is greatly increased, the BR200 substantially shortens actuator inflation and deflation times without significantly changing the steady-state setting. Its flow characteristics suit control valves, and a supply filter prevents air-source particles from entering the instrument; the corrosion-resistant coating and stainless-steel fasteners allow use in corrosive environments.

Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014). Working principle and construction are subject to the official manual.

III. Core Technical Data

ParameterBR200Description
Max Cv (supply)1.2Flow capacity; BR400 is 2.6
Max Cv (exhaust)1.2BR400 is 2.4
Maximum supply pressure150 psi (10.3 bar)Same as BR400
Maximum signal pressure150 psi (10.3 bar)Same as BR400
Input / output pressure ratio1:1Output follows input
Operating temperature (standard)-30 C to +83 C (-22 F to +181 F)Standard range in the manual
Operating temperature (low-temp option)-55 C to +60 C (-67 F to +140 F)Low-temperature option
Operating temperature (high-temp option)0 C to +100 C (32 F to +212 F)High-temperature option
Supply / output port1/4 in NPT or RcBR400 is 1/2 in NPT or Rc
Signal port1/4 in NPT or RcSame as BR400
Approximate weight0.7 kg (1.5 lb)BR400 is 1.4 kg
Body diameter (approx.)86 mm (3.4 in)Approximate from drawing; BR400 is 127 mm
Overall height (approx.)79.5 mm (3.1 in)Approximate from drawing; BR400 is 119 mm

Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), Table 1 Specifications and dimension drawings (Fig. 5 / Fig. 6, marked approximate). Dimensions and parameters are subject to the official manual.

IV. Air Supply Requirements & Installation

Air supply: use clean, dry, oil-free instrument-grade air complying with ANSI/ISA-S7.3 (R1981); a dew point at least 18 F (10 C) below the lowest expected ambient temperature; particles filtered to below 5 µm; oil content < 1 ppm (w/w or v/v); and no corrosive contaminants or flammable / toxic gases.

Installation: mount as close to the actuator as possible; connect the relay to the actuator with a short 1/2 in fitting that serves as both the pneumatic connection and mounting support; the exhaust pointing downward is preferred, though horizontal mounting is acceptable; supply and output lines should be at least 1/2 in, and anaerobic sealants such as Loctite Hydraulic Seal 542 are recommended, while PTFE tape is prohibited to avoid debris entering the instrument.

Hazardous area: this instruction manual (GEA30642A) does not list explosion / hazardous-area certification; the Masoneilan brochure lists ATEX, FM and CSA certifications for the BR200/BR400 with a temperature range marked -40 C to +83 C. A volume booster is a purely pneumatic amplifying accessory and is not itself an electrical explosion-proof device; certification is subject to the product certificate and selection brochure, and the specific certificates and area classification must be confirmed with Baker Hughes.

Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), air supply section, and the Masoneilan Condensed Catalog. Hazardous-area certification is subject to the product certificate and selection brochure; no certification class is invented here.

V. Materials of Construction

PartStandard material
Body / CaseDie-cast aluminum alloy
Upper / Lower diaphragmChloroprene / polyester
Seal plateAustenitic stainless steel
Exhaust seat / exhaust seal guide / plug capCopper alloy
Coil spring / plug / bypass valve plugAustenitic stainless steel
Supply / signal filterAustenitic stainless steel

The manual notes that a stainless-steel version of the BR400 is available for marine / offshore applications, but does not give a model suffix for that stainless version; this article therefore does not invent an order code. The complete parts list is subject to the official manual.

Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), Materials of Construction section (parts 1-17).

VI. Selection Guide & Common Models

Selection guide: BR200 selection follows "function category first, flow and port second, materials and certification last". First confirm the need is volume amplification to speed up actuator travel rather than pressure regulation; if stable supply pressure is required, select an air filter regulator (such as the Series 78) rather than misapplying the BR200. Second, set Cv and port from actuator volume and required stroking time: the BR200 (Cv 1.2, 1/4 in) has lower flow and the BR400 (Cv 2.6, 1/2 in) has higher flow. Third, choose the temperature range and materials by environment; consult about the BR400 stainless marine version for marine / offshore use. Fourth, verify hazardous-area certification with Baker Hughes. Ordering codes (port, material and certification suffixes) are not given in this manual and must be taken from the Masoneilan selection brochure / data sheet; this article does not invent model codes.

Common models: Masoneilan BR200 high-capacity pneumatic volume booster (Cv 1.2, 1/4 in NPT or Rc, about 0.7 kg); the related BR400 (Cv 2.6, 1/2 in port, about 1.4 kg, optional stainless marine version). Both are volume boosters, not filter regulators; specific ordering models are subject to the official selection brochure.

If you are specifying a volume booster for a large cylinder or diaphragm actuator, or want to confirm the difference in flow and port between the BR200 and BR400, please feel free to contact us. We can review the model and installation scheme together against your actuator volume, stroking-time requirement, air supply and certification needs.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.