| Masoneilan BR200 Volume Booster - Working Principle & Technical Data | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-21 02:05:02 | Views: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Masoneilan BR200 is a high-capacity pneumatic volume booster relay from Masoneilan (now part of Baker Hughes), used to speed up the stroking of large-volume diaphragm or piston actuators. Note that the BR200 is a pneumatic volume booster relay (also called a booster relay), not an air filter regulator; the two are different categories with different functions and must not be confused. Based on the official instruction manual, this article covers its working principle, technical data, air supply requirements and selection points. I. Product Positioning
The BR200 and BR400 belong to the same Masoneilan high-capacity volume booster family: the BR200 has a smaller port (lower Cv, 1/4 in connection) and the BR400 has a larger flow capacity (1/2 in connection). They are used on control valves with demanding stroking-time requirements or large actuator volumes, working with positioners to reduce response delay. A volume booster is a purely pneumatic accessory with no electrical body; it must be clearly distinguished from regulators, lock-up valves and other functional accessories. Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014). Product category and parameters are subject to the official manual.
II. Working PrincipleThe BR200 uses a diaphragm force-balance 1:1 amplification principle, working as follows:
Because output pressure follows input pressure at 1:1 while flow capacity is greatly increased, the BR200 substantially shortens actuator inflation and deflation times without significantly changing the steady-state setting. Its flow characteristics suit control valves, and a supply filter prevents air-source particles from entering the instrument; the corrosion-resistant coating and stainless-steel fasteners allow use in corrosive environments. Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014). Working principle and construction are subject to the official manual. III. Core Technical Data
Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), Table 1 Specifications and dimension drawings (Fig. 5 / Fig. 6, marked approximate). Dimensions and parameters are subject to the official manual. IV. Air Supply Requirements & InstallationAir supply: use clean, dry, oil-free instrument-grade air complying with ANSI/ISA-S7.3 (R1981); a dew point at least 18 F (10 C) below the lowest expected ambient temperature; particles filtered to below 5 µm; oil content < 1 ppm (w/w or v/v); and no corrosive contaminants or flammable / toxic gases. Installation: mount as close to the actuator as possible; connect the relay to the actuator with a short 1/2 in fitting that serves as both the pneumatic connection and mounting support; the exhaust pointing downward is preferred, though horizontal mounting is acceptable; supply and output lines should be at least 1/2 in, and anaerobic sealants such as Loctite Hydraulic Seal 542 are recommended, while PTFE tape is prohibited to avoid debris entering the instrument. Hazardous area: this instruction manual (GEA30642A) does not list explosion / hazardous-area certification; the Masoneilan brochure lists ATEX, FM and CSA certifications for the BR200/BR400 with a temperature range marked -40 C to +83 C. A volume booster is a purely pneumatic amplifying accessory and is not itself an electrical explosion-proof device; certification is subject to the product certificate and selection brochure, and the specific certificates and area classification must be confirmed with Baker Hughes. Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), air supply section, and the Masoneilan Condensed Catalog. Hazardous-area certification is subject to the product certificate and selection brochure; no certification class is invented here. V. Materials of Construction
The manual notes that a stainless-steel version of the BR400 is available for marine / offshore applications, but does not give a model suffix for that stainless version; this article therefore does not invent an order code. The complete parts list is subject to the official manual. Source: Masoneilan "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014), Materials of Construction section (parts 1-17). VI. Selection Guide & Common ModelsSelection guide: BR200 selection follows "function category first, flow and port second, materials and certification last". First confirm the need is volume amplification to speed up actuator travel rather than pressure regulation; if stable supply pressure is required, select an air filter regulator (such as the Series 78) rather than misapplying the BR200. Second, set Cv and port from actuator volume and required stroking time: the BR200 (Cv 1.2, 1/4 in) has lower flow and the BR400 (Cv 2.6, 1/2 in) has higher flow. Third, choose the temperature range and materials by environment; consult about the BR400 stainless marine version for marine / offshore use. Fourth, verify hazardous-area certification with Baker Hughes. Ordering codes (port, material and certification suffixes) are not given in this manual and must be taken from the Masoneilan selection brochure / data sheet; this article does not invent model codes. Common models: Masoneilan BR200 high-capacity pneumatic volume booster (Cv 1.2, 1/4 in NPT or Rc, about 0.7 kg); the related BR400 (Cv 2.6, 1/2 in port, about 1.4 kg, optional stainless marine version). Both are volume boosters, not filter regulators; specific ordering models are subject to the official selection brochure. If you are specifying a volume booster for a large cylinder or diaphragm actuator, or want to confirm the difference in flow and port between the BR200 and BR400, please feel free to contact us. We can review the model and installation scheme together against your actuator volume, stroking-time requirement, air supply and certification needs. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |