Emerson AMS Trex 2 TREX2CHPNAWS1S Device Communicator - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Emerson AMS TREX 2 second-generation field communicator TREX2CHPNAWS1S. This is the entry-level HART configuration of the new TREX 2 platform; the ordering code decodes digit by digit as TREX2 (second-generation hardware platform) / C (Device Communication Module, HART + FF communication hardware) / H (HART application only) / P (rechargeable Li-Ion power module) / NA (No Approval, no intrinsic-safety certification, safe areas only) / W (Wireless, Wi-Fi + Bluetooth Low Energy) / S1 (1-year product support) / S (soft carrying case). The knowledge base returned only purchasing and supply-capability records and no dedicated technical document for the AMS TREX; the specifications below are taken from the Emerson official product data sheet of August 2026, for selection and spare-part verification. This arrival must be strictly distinguished from the first-generation TREXCHPNAWS1 (No. 1357) and TREXLHPKLWS3S (No. 1365).
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | Emerson (AMS asset-management software / field-device-management product line) |
| Category | AMS TREX 2 device communicator (field communicator), a second-generation handheld field instrument with loop-check and diagnostic functions |
| Model | TREX2CHPNAWS1S (second-generation TREX2 basic HART configuration; distinct from the first-generation TREXCHPNAWS1 and TREXLHPKLWS3S) |
| Ordering code decoded | TREX2 = second-generation base platform; C = Device Communication Module (HART + FOUNDATION Fieldbus communication hardware); H = HART application only (FF requires the F licence); P = rechargeable Li-Ion power module; NA = No Approval; W = Wireless (Wi-Fi + BLE); S1 = 1-year product support; S = soft carrying case |
| Core capabilities | Field configuration, calibration and diagnosis of HART devices; pre-installed DD library for over 2,500 HART / FF / Bluetooth devices; Auto Sync to AMS Device Manager via Wi-Fi/USB; 5.7 in touchscreen and embedded Bluetooth |
| Key limitations | This unit uses the C module, not the L / Device Communication Plus module, so it has no ammeter and does not support Power the Loop or Loop Diagnostics; NA means no intrinsic-safety certification, safe areas only; FOUNDATION Fieldbus requires the separate F application licence |
| Generation distinction | The second-generation TREX 2 (1.2 GHz quad-core Cortex-A53 / custom Android 14 / 64 GB + 4 GB / BLE) and the first-generation TREX (800 MHz Cortex A8 / Windows Embedded Compact 2013 / 2 GB + 32 GB + 512 MB / Bluetooth 2.1) are different platforms and their specifications must not be interchanged |
| Source status | No dedicated technical document exists in the knowledge base; parameters were obtained online from the Emerson official product data sheet and distributor pages; digit-by-digit ordering details are subject to the official ordering guide, nameplate or purchase order |
III. Technical Data
The specifications below are taken from the Emerson official product data sheet "Next Generation AMS Trex Device Communicator with embedded Bluetooth connectivity" (August 2026 edition; Specifications table and Ordering Information table) and the official ordering-code notes. The second-generation TREX 2 platform uses a 1.2 GHz quad-core Cortex-A53 / NXP i.MX 8M Mini, custom Android 14, 64 GB NAND + 4 GB RAM and Bluetooth Low Energy; its specifications must not be interchanged with those of the first-generation TREX (Nos. 1357 / 1365), which uses an 800 MHz Cortex A8, Windows Embedded Compact 2013, 2 GB + 32 GB + 512 MB and Bluetooth 2.1. This unit carries the C module (Device Communication Module, HART + FF hardware) with the H application enabling HART only, and the NA (no approval) certification position. Items not listed item by item in the official materials are flagged honestly and are subject to the nameplate / purchase order or the official manual, with no values assumed.
| Item | Specification |
|---|---|
| Platform / generation | TREX2 second-generation hardware platform; 1.2 GHz quad-core ARM Cortex-A53 / NXP i.MX 8M Mini microprocessor. A different generation from the first-generation TREXCHPNAWS1 and TREXLHPKLWS3S |
| Operating system and memory | Custom Android 14 platform; internal flash 64 GB NAND; RAM 4 GB LPDDR4 SDRAM (the first generation uses Windows Embedded Compact 2013 / 2 GB + 32 GB / 512 MB) |
| Display and keypad | 5.7 in (14.5 cm) colour VGA resistive touchscreen, 640 x 480 pixels; adjustable backlight and glove-operable; X / four-way / checkmark keys |
| Communication module C | Device Communication Module: HART terminal and FOUNDATION Fieldbus terminal (two banana jack plugs each). Note: the C module has no ammeter and does not support Power the Loop / Loop Diagnostics, which belong to the L / Device Communication Plus module |
| Protocols and applications | H = HART Application (HART only) in this unit; FOUNDATION Fieldbus requires the separate F application licence (HART + FOUNDATION Fieldbus Applications); pre-installed DD library for over 2,500 HART / FF / Bluetooth devices |
| Wireless (W) | W = Wireless: Wi-Fi 802.11 b/g/n 2.4 GHz (range up to 33 m) plus Bluetooth Low Energy (range up to 15 m); embedded Bluetooth is a hallmark of this generation |
| Power and battery (P) | P = rechargeable Li-Ion power module; 8+ hours of typical use, 3-4 hour charge time; AC adapter input 100-240 VAC, 50-60 Hz |
| Approval (NA) | NA = No Approval: this unit carries no ATEX / CSA / CCC / IECEx / FISCO intrinsic-safety certification and is for safe areas only; other TREX 2 configurations offer KL (intrinsically safe). NA and KL must not be interchanged |
| Operating / storage temperature | Usage -20 to +55 degC (-4 to +131 degF); -20 to +50 degC for IS approval; charging +10 to +45 degC; storage with power module -20 to +50 degC (less than 1 month), without power module -20 to +60 degC |
| Enclosure and shock | IP54; survives a 1 m all-sides-and-corners drop test onto concrete; enclosure designed to limit static electrical build-up per intrinsic-safety principles |
| Weight | Unit approx. 2.9 lbs (1330 g); shipping weight 6-7 lbs (approx. 3.1 kg, based on TREX2LHPKLWP3) |
| Applications and sync | Pre-installed Field Communicator, AMS Device Configurator, Loop Diagnostics, Fieldbus Diagnostics, WirelessHART Provisioning, ValveLink Mobile, Calculator, Trex Help and PDF Viewer apps; Auto Sync time-stamps and synchronises changes to AMS Device Manager |
| Ordering-code positions | Full designation TREX2-C-H-P-NA-W-S1-S: platform / communication module / application / power / approval / radio / support / option positions are explained in the Brand section; details are subject to the official ordering guide, nameplate or purchase order |
| Documentation note | The data sheet is the August 2026 edition; digit-by-digit ordering codes and approval marking of TREX2CHPNAWS1S are subject to the official ordering guide, nameplate or purchase order; items not listed in the available materials are not assumed |
These data were obtained via online search. Sources: the Emerson official product data sheet "Next Generation AMS Trex Device Communicator with embedded Bluetooth connectivity" (August 2026, emerson.com/trex; original PDF published under emerson.com/is/content/emerson/en/systems-and-software/ams/product-data-sheets/documents/), whose Specifications and Ordering Information tables are the primary basis for the technical data and the digit-by-digit ordering code (TREX2 / C / H / P / NA / W / S1 / S); distributor pages from Transcat, Eurotron Benelux and xktransmitter listing the TREX2CHPNAWS1S stock configuration corroborate the model designation. The knowledge base returned only purchasing records (TREX2CHPNAWS1S and TREX2CHPNAWS1 communicators), the Baoman supply-capability summary and similar documents, with no dedicated technical document for the AMS TREX, so online verification was performed. The first-generation TREX (Nos. 1357 / 1365) and the second-generation TREX 2 have been strictly distinguished; the C and L modules and the NA and KL approvals are not interchanged.
IV. Related Models
| Item | Specification |
|---|---|
| TREXCHPNAWS1 (No. 1357, first generation) | Classic first-generation TREX platform: 800 MHz ARM Cortex A8 / Windows Embedded Compact 2013 / 2 GB + 32 GB + 512 MB / Bluetooth 2.1, with the C module (HART + FF). A different generation from the second-generation TREX2 in this arrival; specifications must not be interchanged |
| TREXLHPKLWS3S (No. 1365, first generation) | First-generation L configuration (Device Communication Plus module with mA measurement and Power the Loop), with KL intrinsic-safety approval and S3 three-year support; this arrival is a second-generation C module with NA no approval and S1 one-year support - a different configuration |
| TREX2 L-module high configuration (e.g. TREX2LHPKLWP3S) | Second-generation Device Communication Plus module with built-in ammeter, Power the Loop, NIST-traceable calibration and Loop Diagnostics; the C module in this arrival does not have these functions, so selection must distinguish them |
| TREX2 C H P KL W S1 S (basic HART intrinsically-safe version) | The Basic HART Model Number in the official data sheet: same C/H/P/W/S1/S positions as this unit but with KL approval (ATEX/CSA/CCC/IECEx intrinsically safe); this arrival is the NA no-approval version for safe areas only, and the two must not be interchanged |
| 375 / 475 HART communicators | Previous-generation HART communication devices, a different product class from the AMS TREX 2; this arrival is the second-generation TREX 2 platform |
V. Selection Guide & Common Models
Selection guide:Selection starts with the generation and module: this arrival is a second-generation TREX2 with the C module (HART + FF communication hardware), HART application only and NA no approval. If mA measurement, loop powering (Power the Loop) and loop diagnostics are required, choose the L / Device Communication Plus module instead; FOUNDATION Fieldbus requires the separate F application licence. Pay particular attention to the approval position: NA carries no intrinsic-safety certification and is for safe areas only; hazardous areas require the KL intrinsically-safe configuration, and the two must not be interchanged. Then check the application against the 5.7 in touchscreen, -20 to +55 degC operating range, IP54 rating, 8+ hour runtime and Wi-Fi / Bluetooth BLE conditions, and confirm that the one-year S1 support meets your needs. Digit-by-digit ordering details and approval markings are subject to the official ordering guide, nameplate or purchase order. Please feel free to inquire for an item-by-item check against your field protocols and device list.
Common models:This arrival: the Emerson AMS TREX 2 second-generation field communicator TREX2CHPNAWS1S (C communication module, HART application only, NA no approval, wireless, 1-year support, soft carrying case). Parameters were obtained online from the Emerson official product data sheet and are for selection and spare-part verification only, not guaranteed values. The specific configuration, position decoding and approval markings are subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed. It is strictly distinct from the first-generation TREXCHPNAWS1 and TREXLHPKLWS3S.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文