Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the ControlAir 6100-EA high-flow pneumatic volume booster. ControlAir is a US brand and Baoman is its authorised distributor; the 6100-EA is the aluminium model of the Type 6100/6200 High Flow Capacity Volume Booster series, a 1:1 signal/output relay used to increase the stroking speed of large-flow control valves (diaphragm or piston actuators), widely applied on anti-surge valves. The model decodes as 6100 (aluminium body) + E (3/4" NPT port) + A (aluminium material mark); this model carries no option suffix (options such as E threaded exhaust, L low temperature, X ATEX must be added separately). The series is EXIDA-certified to IEC 61508 SIL 3 for use in safety instrumented systems (SIS). Parameters are taken from the original ControlAir specification sheet 6100-6200_SpecSheet.pdf (P/N 441-625-069) recorded in the knowledge base, for selection and spare-part verification.

I. Arrival Photos

ControlAir 6100-EA high-flow pneumatic volume booster (1:1 signal/output, aluminium body, 3/4
Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

ControlAir 6100-EA high-flow pneumatic volume booster (1:1 signal/output, aluminium body, 3/4
Arrival and unboxing detail (taken by Baoman Industrial)

ControlAir 6100-EA high-flow pneumatic volume booster (1:1 signal/output, aluminium body, 3/4
Arrival and unboxing detail (taken by Baoman Industrial)

ControlAir 6100-EA high-flow pneumatic volume booster (1:1 signal/output, aluminium body, 3/4
Arrival and unboxing detail (taken by Baoman Industrial)

ControlAir 6100-EA high-flow pneumatic volume booster (1:1 signal/output, aluminium body, 3/4
Arrival and unboxing detail (taken by Baoman Industrial)

II. Brand & Model

ItemSpecification
BrandControlAir (a US brand; Baoman Industrial Technology (Chengdu) Co., Ltd. is its authorised distributor)
Model6100-EA high-flow pneumatic volume booster, Type 6100/6200 series
Positioning1:1 signal/output pneumatic booster for applications requiring high forward flow and exhaust capacity, increasing the throttling speed of large-flow control valves (diaphragm or piston actuators); fixed deadband plus adjustable bypass valve, with tight shut-off from soft seats at steady state
Model decoded character by character6100 = series number, aluminium body (6200 = 316 stainless steel); E = Port Code 3/4" NPT (B = 1/4", D = 1/2", E = 3/4"); A = Material mark aluminium (S = 316 stainless steel, matched to the 6200). This model carries no option suffix
Typical applications and certificationAnti-surge valves, high-flow/high-temperature/radiation environments (e.g. nuclear industry); EXIDA-certified to IEC 61508 SIL 3 for SIS use; EAC (GOST) and other certification systems available on request, subject to the order confirmation
Source statusThe knowledge base contains a dedicated ControlAir Amplifier Technical Data and Model Rules Summary, whose Type 6100/6200 chapter is transcribed verbatim from six original specification-sheet PDFs; parameters follow the latest original specification sheet and no values are assumed

III. Technical Data

The specifications below are transcribed item by item from section five 'Type 6100/6200 - High Flow Capacity Volume Booster' of the knowledge-base document ControlAir Amplifier Technical Data and Model Rules Summary (entry_id 48403c848a9c4804a578c63be72fea04, Product Selection Rules space), whose data source is the original ControlAir specification sheet 6100-6200_SpecSheet.pdf (P/N 441-625-069, 6/3/26 edition). The SIL 3 and EAC certification background is supplemented from the knowledge-base documents Baoman Supply Capability Summary and Baoman Corporate Brochure. The Cv, pressure, ports and materials for the 6100-EA are taken from the 6100 column (3/4" port) of that original sheet, with the 6200 as the stainless-steel comparison column and no mixing of the two; option codes and accessory part numbers are transcribed as-is, with no values assumed.

ItemSpecification
Model decoded character by character6100 (series number, aluminium body) + E (Port Code: 3/4" NPT) + A (Material: aluminium, matched to 6100); the complete standard model 6100-EA = aluminium body, 3/4" NPT. Option codes E/L/P/S/X/Z are added separately, e.g. 6100-EA-E = 3/4" NPT aluminium body plus threaded exhaust
Construction and principle1:1 signal/output high-flow pneumatic booster; fixed deadband plus integral adjustable bypass valve, so small signal changes do not open the main valve; the bypass tunes dynamic response for stability across a wide range of actuator sizes; soft-seat design gives tight shut-off and eliminates leakage at steady state
Signal/output ratio1:1
Supply pressure250 psig (17.0 bar) maximum
Signal pressure150 psig (10.0 bar) maximum
Maximum flow coefficient Cv (6100, 3/4" port)Forward 5.0 / exhaust 3.5 (6100 3/4" NPT port column; note the 1/4" port is forward 2.0 / exhaust 2.5 and the 1/2" port is forward 4.5 / exhaust 3.5 - Cv differs by port and must not be interchanged)
Exhaust capacity (3/4")80 scfm (approx. 2,264 Nl/min)
Temperature range (standard)-40 to 200 F (-40 to 93 C); low-temperature option L: -62 to 194 F (-52 to 90 C); extended-temperature option P: -55 to 284 F (-48 to 140 C)
PortsSignal port 1/4" NPT; supply/output ports 1/4", 1/2" or 3/4" NPT (this model 3/4"); exhaust port for the 6100 is 7/16" or optional 1/4" NPT (option E threaded exhaust); gauge ports (2) 1/4" NPT
Materials of constructionBody 6100 = aluminium (6200 = 316 stainless steel); fasteners 6100 = zinc-plated steel (6200 = stainless steel); other external parts 6100 = aluminium; internal parts 6100 = aluminium; elastomers standard nitrile, low-temperature option = silicone, extended-temperature option = EPDM. Stainless-steel trim available (option S, 6100 only)
Output accuracy and deadbandOutput accuracy: 1.0% of 100 psi output span; deadband < 0.2 psig (0.01 bar); sensitivity 1" H2O (2.54 cm); a 25 psig (1.7 bar) supply change causes a 0.1 psig (0.007 bar) output change
Weight and bias6100 approx. 2.5 lbs (1.13 kg); 6200 approx. 5.7 lbs (2.60 kg). Optional negative bias 4 psi (0.3 bar), option Z = -4 +/-1 psi, for I/P converter zero reset
Safety certificationIEC 61508 SIL 3 (EXIDA third-party certification, usable in safety instrumented systems SIS); EAC (GOST) and other certification systems available on request (option X = ATEX 2014/34/EU Ex certification, subject to order confirmation). No specific certificate number is assumed here; refer to the original certificates and order documents
Options and accessoriesStackable options: E = (2)1/4" NPT threaded exhaust (6100 only), L = low temperature, P = extended temperature, S = stainless-steel trim (6100 only), X = ATEX, Z = negative bias. Mounting brackets and other accessories are ordered by separate part numbers (e.g. P/N 449-542-045) and are not included in the model suffix

Sources: the knowledge-base document ControlAir Amplifier Technical Data and Model Rules Summary (entry_id 48403c848a9c4804a578c63be72fea04, Product Selection Rules space), whose section five on Type 6100/6200 is transcribed verbatim from the original ControlAir specification sheet 6100-6200_SpecSheet.pdf (P/N 441-625-069, 6/3/26 edition); model coding, Cv, pressure, ports, materials, temperature and option codes are copied from that PDF. The SIL 3 / EAC and anti-surge-valve background is supplemented from the knowledge-base documents Baoman Supply Capability Summary (entry_id ff56f4683ec84bc0ab9ee501a1feba94) and Baoman Corporate Brochure (entry_id 144c03afaab14159b2ad7ce9b666eb51); a purchasing record (entry_id a9d9ab0f051447ca99f6ac7e74d261b1) contains a 6100-EA booster entry that corroborates the arrival model. Items not listed or pending confirmation are flagged honestly; no values are assumed.

IV. Related Models

ItemSpecification
6100-BA / 6100-DAThe 1/4" NPT (BA) and 1/2" NPT (DA) port versions of the same Type 6100 aluminium high-flow booster; Cv varies by port (1/4" forward 2.0, 1/2" forward 4.5) and must not be interchanged with the 6100-EA's 3/4" (forward 5.0)
6200-ESThe 316 stainless-steel model of the Type 6100/6200 series, 3/4" NPT; Cv is forward 4.0 / exhaust 4.0 and weight 5.7 lbs (2.60 kg), with materials and Cv different from the aluminium 6100-EA
6100-EA-EThe full designation of a 6100-EA with option E ((2)1/4" NPT threaded exhaust); this arrival is the base 6100-EA without that option, so the two must be distinguished when ordering
ControlAir 6500 / 6600Large Flow Capacity Volume Boosters, 3/4" or 1" NPT, Cv 8.0/9.0, exhaust 150 scfm, also IEC 61508 SIL 3; a higher flow class than the 6100 series, to be distinguished by duty
ControlAir 6000 / Type 600The 6000 is a volume booster (Cv 6.6/6.8, 300 scfm, no SIL certification); the Type 600 is a ratio relay volume booster (1:1 and 1:2/1:3/1:6 ratios, Cv 1.0, no SIL). Both differ from the 6100's 1:1 high-flow plus SIL 3 positioning
Fisher 2625 / Masoneilan BR400 volume boostersAlternative large-flow pneumatic boosters from other brands, compared in the knowledge-base documents Fisher Volume Booster Technical Data Summary and Masoneilan BR200/BR400 Volume Booster Technical Data and Model Rules; selection requires item-by-item checks of Cv, ports and certification, with no interchange of specifications

V. Selection Guide & Common Models

Selection guide:Selection starts with flow and actuator volume: the 6100-EA is a 1:1 high-flow pneumatic booster with 3/4" NPT ports, Cv forward 5.0 / exhaust 3.5 and exhaust 80 scfm, suited to large-flow diaphragm/piston actuators and anti-surge valves; for higher flow (Cv 8.0/9.0, 150 scfm) choose the 6500/6600, and for ratio amplification choose the Type 600. Then check pressures (supply 250 psig max, signal 150 psig max), ports (this model supply/output 3/4" NPT, signal 1/4" NPT), materials (6100 aluminium body/nitrile elastomers; for corrosive service choose the 6200 316 stainless steel or option S stainless-steel trim), temperature (standard -40 to 93 C, option L for low temperature, option P for extended temperature) and options (E threaded exhaust, Z negative bias, X ATEX). For SIS applications verify the IEC 61508 SIL 3 (EXIDA) certificate and the EAC/ATEX ordering options. Cv differs by port, so check against the actual port size; the complete ordering code is subject to the nameplate/purchase order or the original specification sheet. Please feel free to inquire for an item-by-item check against your actuator volume and duty.

Common models:This arrival: the ControlAir 6100-EA high-flow pneumatic volume booster (aluminium body, 3/4" NPT, 1:1, Cv forward 5.0 / exhaust 3.5, IEC 61508 SIL 3), strictly distinct from the 6200 stainless-steel series, the 6500/6600 large-flow series and the non-SIL 6000/Type 600 models. Parameters come from the original ControlAir specification sheet 6100-6200_SpecSheet.pdf (P/N 441-625-069) recorded in the knowledge base, for selection and spare-part verification only, not guaranteed values. The specific configuration and certification are subject to the nameplate/purchase order or the original certificates, and items not listed in the available materials are not assumed.

These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.

Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.

Ordering & Inquiry

The photos above show the models currently in stock. If you are working through a similar selection, or would like to know more about a model's configuration and availability, feel free to get in touch — we can look at the right combination together based on your valve type and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area