Home » News Center » Product Arrival Display
Flowserve Valtek XL XLL3W1L11B100 Valve Positioner - Arrival & Data
Flowserve Valtek XL XLL3W1L11B100 Valve Positioner - Arrival & Data
Flowserve Valtek XL XLL3W1L11B100 Valve Positioner - Arrival & Data

Flowserve Valtek XL XLL3W1L11B100 Valve Positioner - Arrival & Data

Details

Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Flowserve XL series XLL3W1L11B100 valve positioner with pressure gauges. The Valtek XL series is a two-stage high-performance analog positioner (not a microprocessor-based smart positioner), available with a pneumatic P/P module (3-15 psi) or an NT3000 electro-pneumatic I/P transducer module (4-20 mA), for single/double-acting and linear/rotary service, field reversible with changeable flow characteristics. The received unit carries two stainless-steel pressure gauges and a nameplate showing an NT3000 Transducer with EXPLOSION PROOF / INTRINSICALLY SAFE markings. The knowledge base contains only Flowserve Logix digital positioner and PMV positioner material, with no XL-series technical entry and no digit-by-digit table for XLL3W1L11B100; web verification was therefore performed and sources are explicitly cited. Public official literature does not publish a per-character explanation of this complete order string, so undocumented fields are not assumed. Note in particular that the XL is an analog positioner, a different product line and brand scope from the Logix 3800/3800e digital positioners and the PMV D3/D20/D30, and they must not be interchanged. Parameters are for selection and spare-part verification only.

I. Arrival Photos

Flowserve Valtek XL series XLL3W1L11B100 high-performance analog valve positioner with pressure gauges arrival photo 1
Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Flowserve Valtek XL series XLL3W1L11B100 high-performance analog valve positioner with pressure gauges arrival photo 2
Arrival and unboxing detail (taken by Baoman Industrial)

Flowserve Valtek XL series XLL3W1L11B100 high-performance analog valve positioner with pressure gauges arrival photo 3
Arrival and unboxing detail (taken by Baoman Industrial)

II. Brand & Model

ItemSpecification
BrandFLOWSERVE (Valtek Control Products, USA; the XL is a Valtek analog positioner platform)
ModelXLL3W1L11B100, designated on arrival as an XL series high-performance valve positioner with pressure gauges; no per-character explanation of this complete order string is published in the available official literature
PositioningA two-stage, high-gain analog positioner for control loops requiring fast response; field-convertible between P/P (3-15 psi pneumatic) and I/P (NT3000, 4-20 mA) modules; for single/double-acting and linear/rotary service with split ranging, sharing mounts with Beta/80R (the XL90 shares rotary brackets with the Logix 1000)
Boundary with Logix/PMV (red line)The XL is an analog (P/P or I/P) positioner with no microprocessor, no HART/FF/PA communication and no self-diagnostics. The Logix 3800/3800e are digital positioners and the PMV D3/D20/D30 belong to another brand of digital positioner (PMV has been divested). Their technical data must not be mixed and spare parts / orders must be strictly separated by product line
Arrival designation and unitPhotos show the red XL SERIES badge, two Ashcroft stainless-steel pressure gauges and an NT3000 transducer nameplate marked EXPLOSION PROOF / INTRINSICALLY SAFE. A closely related complete order string appears in a CNPC procurement record, "XLL3W1L21B100-NT3002042SN1W00", where one field is 21 rather than 11 in this arrival; the meaning of that field must be confirmed with Flowserve or against the nameplate / purchase order
Source statusThese data were obtained via web search: official Flowserve Valtek XL-series literature and IOM plus a public procurement record. The knowledge base has no XL-series technical entry. Per-character decoding of the order string is not public and is not assumed; undocumented fields are marked "confirm with the manufacturer / subject to the nameplate or purchase order"

III. Technical Data

These data were obtained via web search. Sources: the Flowserve/Valtek datasheet "Valtek XL Series Positioners" (VLATB048 / FCD VLATB045-07, PDF at https://pro-quip.com/wp-content/uploads/2024/01/Valtek-XL-Positioner.pdf), the "Valtek XL Series High-Performance Positioner" IOM (Pub. 10077320 / 45-1, PDF at https://pro-quip.com/wp-content/uploads/2024/01/Valtek-XL-High-Performance-Positioner.pdf), the Flowserve XL/XL90 product page (https://www.flowserve.com/en/products/products-catalog/actuators-instrumentation/positioners/analog-positioners-valtek-xl-xl90/), and a CNPC procurement notice PDF containing "XLL3W1L21B100-NT3002042SN1W00" to corroborate that this order-string format belongs to the Flowserve XL series. The knowledge base has no XL-series technical entry (only Logix and PMV material, entry_ids a88cc5db092d46bea8b83fdbbb899cfd and 3d5bf01927394a32b93cb59b51744c24), so web sources were used and explicitly cited as required. The official literature publishes the XL90 model-numbering fields (prefix / input model / indication / gauges / temperature / cam / conduit / options / output shaft) but not a per-character explanation of the complete string XLL3W1L11B100; undocumented parts are flagged as pending confirmation and no values are assumed.

ItemSpecification
Data obtained via web searchAll specifications below are from the official Flowserve/Valtek XL-series datasheet and IOM; no XL technical entry exists in the knowledge base, with sources in the src field
Decoding basis for order code XLL3W1L11B100No per-character explanation of this complete order string is published in the available official literature, so none is assumed. What can be confirmed: XLL3W1L...B100 is a Flowserve XL-series order-string format (a CNPC procurement record also lists XLL3W1L21B100-NT3002042SN1W00, with an NT3000... suffix for the I/P transducer module). The exact meaning of the XL prefix, the numeric fields and B100 must be confirmed with Flowserve or against the nameplate / purchase order
Official XL90 model-numbering fields (for reference only, not a digit-by-digit conclusion for this model)The official datasheet publishes the XL90 numbering as: prefix (manufacturer / finish, e.g. VW = Valtek white epoxy) / input model (90 = pneumatic 3-15 psi; 91 = general-purpose NT3000 I/P; 92 = FM/CSA explosion-proof and intrinsically safe; 93 = CENELEC EEx d; 94 = CENELEC EEx ia/ib; 95 = SAA Ex d / Ex ia) / indication / gauges (2 = stainless gauge with brass fittings standard, 4 = bar/psi/kPa, 8 = stainless gauge, Z = no gauge) / temperature (7 = standard, 8 = extended) / cam / conduit (P = 1/2 NPT, R = M20) / options / output shaft (D = Double D, L = NAMUR)
ConstructionA two-stage, high-gain positioner: signal pressure acts on the input capsule against feedback-spring tension (via feedback arm and cam); imbalance moves the capsule and pilot valve to change output pressures on both actuator sides until equilibrium. Designed as a four-way device, it becomes three-way by plugging one output port
Input signalP/P pneumatic module 3-15 psi (0.21-1.03 bar), optional 6-30 psi (0.41-2.1 bar) with two-, three- and four-way split range; I/P module 4-20 mA, optional 10-50 mA with two-, three- and four-way split range. The I/P version uses an NT3000 series transducer (the I/P 2000 is not acceptable)
Air supply and qualitySupply pressure 30-150 psi (2.1-10.3 bar); all ports withstand 150 psi so a supply regulator is usually unnecessary, but a 5-micron filter is required for pneumatic positioners and a coalescing filter for I/P positioners; air per ISA S7.3 (dew point at least 18 F / 10 C below ambient, particles below 5 microns, oil not exceeding 1 ppm)
Dead band and linearityDead band 0.1% FS; hysteresis 0.1% FS; resolution 0.1% FS; independent linearity +1.0% FS; repeatability 0.1% FS, identical for pneumatic and I/P models
Air consumption and flowSteady-state consumption at 60 psi: pneumatic 0.28 SCFM (0.47 m3/h), I/P 0.34 SCFM (0.58 m3/h); maximum flow capacity at 60 psi is 16.5 SCFM (28 m3/h) for both; gain 400-1100:1 (pneumatic) and 535-1465:1 (I/P)
Pressure gauges (arrival feature)The received unit carries two stainless-steel pressure gauges (Ashcroft). The official GAUGES field lists 2 = stainless gauge with brass fittings (standard), 4 = bar/psi/kPa stainless gauge, 6 = kg/cm2/psi, 8 = stainless gauge and Z = no gauge; gauge connections are 1/8" NPT (also listed as 0.12-inch NPT)
Connections and materialsSupply, instrument and output ports 1/4" NPT; signal conduit 1/2" NPT (M20 optional); gauge port 1/8" NPT. Standard materials are stainless steel, anodized aluminium, epoxy powder-painted steel and nitrile; cover and base are epoxy powder-painted and continuously purged internally with instrument air
Temperature and weightStandard temperature: pneumatic -29 to +85 C (-20 to +185 F), I/P -29 to +82 C (-20 to +180 F); extended temperature: pneumatic -45 to +121 C, I/P -40 to +82 C; net weight approx. 1.4 kg (3 lb) pneumatic and 2.5 kg (5.5 lb) I/P
Hazardous-area approvals (per module and nameplate)With the NT3000 I/P: FM/CSA explosion-proof Class I Div 1 Grp B/C/D and intrinsically safe Class I/II/III Div 1 Grp A-E, CENELEC EEx d IIB+H2 T6 and CENELEC EEx ia IIC T4 (Ta = 80 C). The arrival nameplate shows EXPLOSION PROOF / INTRINSICALLY SAFE markings; the exact certificates, gas group and temperature class must be checked against the nameplate, and intrinsically safe Ex ia and flameproof Ex d must not be mixed
Boundary with digital positionersThe XL has no microprocessor, no communication protocol and no diagnostics. The Logix 3800/3800e are digital positioners and the PMV D3/D20/D30 are digital positioners of another brand. Spare parts, configuration and selection data are not interchangeable

These data were obtained via web search. Sources: (1) the Flowserve/Valtek datasheet "Valtek XL Series Positioners", VLATB048 / FCD VLATB045-07, at https://pro-quip.com/wp-content/uploads/2024/01/Valtek-XL-Positioner.pdf (Table I specifications, Table II NT3000 approvals and the XL90 Model Numbering System); (2) the "Valtek XL Series High-Performance Positioner" IOM, Pub. 10077320 / 45-1, at https://pro-quip.com/wp-content/uploads/2024/01/Valtek-XL-High-Performance-Positioner.pdf; (3) the Flowserve "Analog Positioners - Valtek XL-XL90" product page at https://www.flowserve.com/en/products/products-catalog/actuators-instrumentation/positioners/analog-positioners-valtek-xl-xl90/; (4) a CNPC Daqing procurement notice PDF containing "electro-pneumatic valve positioner XLL3W1L21B100-NT3002042SN1W00" to corroborate the order-string format and NT3000 suffix, and the arrival page https://bit-cd.com/index.php?id=1605 confirming the model, pressure gauges and NT3000 nameplate. The knowledge base has no XL technical entry (the Logix document, entry_id a88cc5db092d46bea8b83fdbbb899cfd, and the PMV document, entry_id 3d5bf01927394a32b93cb59b51744c24, were used only to mark the boundary). Per-character decoding not published in the available literature is flagged as pending confirmation; no values are assumed.

IV. Related Models

ItemSpecification
XLL3W1L21B100-NT3002042SN1W00A closely related XL-series order string in a public procurement record, carrying an NT3000... I/P transducer suffix. It differs from this arrival in one field (21 versus 11); the meaning of that field is not public and must be confirmed with Flowserve or against the nameplate / purchase order; source: CNPC procurement notice PDF
Valtek XL90The rotary version of the XL family with a rotary feedback mechanism up to 180 degrees, sharing rotary brackets with the Logix 1000 and offering a dome indicator, limit switches and 4-20 mA position feedback; source VLATB048
NT3000 I/P transducerThe electro-pneumatic transducer module used with the XL, converting 4-20 mA to 3-15 psi with FM/CSA explosion-proof and intrinsically safe and CENELEC EEx d / EEx ia approvals; visible on the arrival nameplate; source IOM 45-1 and Table II
Flowserve Logix 3800 / 3800eFlowserve digital positioners with HART, a microprocessor and diagnostics, completely different from the analog XL here. The knowledge-base document "Flowserve Logix Positioner Technical Data and Model Rules" (entry_id a88cc5db092d46bea8b83fdbbb899cfd) covers them; selection and spare parts must not be mixed
PMV D3 / D20 / D30Digital positioners of the former Flowserve PMV brand (the brand has been divested), intended only for installed-base maintenance and not a substitute for the XL or Logix. See the knowledge-base document "PMV D3/D20/D30 Digital Positioner Technical Data and Model Rules" (entry_id 3d5bf01927394a32b93cb59b51744c24)

V. Selection Guide & Common Models

Selection guide:Selection first draws the product-line boundary: this XL is an analog positioner, so if the host system requires HART/FF/PA communication or valve diagnostics, choose a digital positioner such as the Logix 3800/3800e rather than expanding the XL; PMV digital positioners are for installed-base maintenance only and must not be used as substitutes here. Next confirm the input type: a 4-20 mA electrical signal needs the NT3000 I/P module (visible on the arrival nameplate), while a 3-15 psi air signal uses the P/P module; the two are field-convertible by swapping modules. Check single/double-acting and linear/rotary service against the actuator (the XL90 covers rotary duty), along with supply 30-150 psi, ISO/ISA air quality with 5-micron filtration (coalescing filter for I/P), dead band 0.1% FS, linearity +1.0% FS, maximum flow 16.5 SCFM at 60 psi, temperature range and weight. Confirm the two stainless-steel gauges and their scale ranges from the arrival photos. For hazardous areas, check the NT3000 module's FM/CSA/CENELEC certificates and nameplate for the exact Ex d or Ex ia gas group and temperature class; intrinsically safe and flameproof types must not be mixed. Most importantly, no per-character decoding of XLL3W1L11B100 is published, so confirm each field with Flowserve against the nameplate / purchase order before ordering. Please feel free to inquire for further assistance.

Common models:This arrival: the Flowserve Valtek XL series XLL3W1L11B100 high-performance analog valve positioner with two stainless-steel pressure gauges (NT3000 I/P module, nameplate marked EXPLOSION PROOF / INTRINSICALLY SAFE). These data were obtained via web search, sourced from the official Flowserve XL-series datasheet VLATB048 and IOM 45-1 among others, for selection and spare-part verification only, not guaranteed values. It belongs to a different product line from the Logix/PMV digital positioners; the per-character decoding of the order code is not public and is subject to the nameplate / purchase order or official confirmation, with no values assumed for items not listed in the available materials.

These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.

Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.

Ordering & Inquiry

The photos above show the models currently in stock. If you are working through a similar selection, or would like to know more about a model's configuration and availability, feel free to get in touch — we can look at the right combination together based on your valve type and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area