Fisher EZR Series Pressure Regulator - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Fisher EZR series pressure reducing regulator. The EZR is a pilot-operated pressure reducing regulator from Fisher (the brand now belongs to Emerson) for natural gas, air or other non-corrosive gases, suitable for transmission and distribution networks and industrial / commercial lines. It uses a Type 112 orifice with a 161AY, 161EB, 161EBH or PRX series pilot, and can be converted to a high-capacity relief valve / backpressure regulator by fitting a relief pilot (Bulletin 71.4:EZR); some configurations include integral shut-off (EZROSX / OS2) providing OPSO / UPSO protection. The EZR differs from the 133H (direct-operated), EZH (high-pressure transmission) and EZL (low pressure); their bore, pressure and flow specifications must not be interchanged. The specifications below are taken from the original manufacturer's instruction manuals D102600X012 / D103681X012 and the official Bulletin recorded in the knowledge base, for selection verification.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | FISHER (now part of Emerson) |
| Model | EZR series (pilot-operated pressure reducing regulator) |
| Positioning | High-capacity pressure reducing regulator for natural gas, air and other non-corrosive gases in transmission / distribution and industrial lines; used with a 161AY (low pressure), 161EB (high precision), 161EBH (high pressure) or PRX series pilot, convertible to a relief / backpressure regulator with a relief pilot, with optional integral shut-off (OPSO, OPSO+UPSO or dual overpressure) |
| Series features | Powder coating, maintenance-friendly pilot, Hydrogen Ready (materials compatibility assessment for hydrogen service); body rating up to ANSI Class 600 and outlet setpoint range approx. 0.35 to 69 bar depending on pilot |
| Arrival designation | The arrival note only states 'EZR series pressure reducing regulator / EZR regulating valve' and gives no bore, end connection, pilot or shut-off options; the specific ordering model is subject to the nameplate / purchase order |
| Source status | The knowledge-base 'Fisher Regulator Technical Data Supplement', volumes 1 and 3, cites the official D102600X012 / D103681X012 manuals and Bulletins; the manual includes a Dimensions and Weights chapter that was not expanded in the retrieved snippets, so item-by-item weights are flagged honestly and not assumed |
III. Technical Data
The specifications below are taken from the Fisher official 'EZR Series Pressure Reducing Regulator' instruction manuals D102600X012 / D103681X012, the EZR Series Bulletin and Bulletin 71.4:EZR (emerson.com), as compiled and cross-checked in the knowledge-base documents 'Technical Data Supplement 01 - Regulators / Reducers (General and Gas)' and 'Technical Data Supplement 03 - Backpressure / Relief / Vent Valves'. The manuals include a Dimensions and Weights chapter that was not expanded in the retrieved snippets; items not listed in the available documents are flagged honestly and are subject to the nameplate / purchase order or the official manual, with no values assumed.
| Item | Specification |
|---|---|
| Construction and principle | Pilot-operated main valve; pressure-balanced with soft seat; the pilot senses downstream pressure and controls main-valve throttling. Used with a Type 112 orifice and a 161AY / 161EB / 161EBH / PRX series pilot, and convertible to a relief valve / backpressure regulator by fitting a relief pilot |
| Body size | NPS 1, 2, 3, 4, 6 (DN 25, 50, 80, 100, 150); the official product page summarises Valve Size as NPS 1 to NPS 30 depending on configuration |
| End connections | Flanges CL150 RF / CL300 RF / CL600 RF, PN 16B / 25B / 40B (others available on order); control line 1/4 in NPT (external sensing) |
| Maximum inlet pressure | Main-valve maximum inlet pressure depends on body size and ASME rating, up to ANSI Class 600; the EZR nominal operating pressure reaches up to 72.4 bar (approx. 1050 psig) |
| Maximum / emergency differential pressure | PN20 / 50 / 100 correspond to max operating differentials of approx. 2 to 3 bar / 18.6 bar / 50 bar, with a maximum emergency differential up to 100 bar (body dependent); the European version has Pmax 96.7 bar (A216 WCB) / 100 bar (A352 LCC) |
| Outlet pressure range | Approx. 0.35 to 69 bar depending on pilot: PRX/120 1 to 40 bar, 161EB 0.34 to 24.1 bar (5 to 350 psig), 161EBH 17.2 to 48.3 bar (250 to 700 psig), 161AY low pressure 6 in w.c. to 7 psig |
| Flow coefficient Cg (100% open) | DN25 480, DN50 1800, DN80 3400, DN100 5550, DN150 11200; no single Cv is given by Emerson, and capacity varies with body size and trim, see manual Table 4 and the Bulletin |
| Main materials | Body carbon / stainless steel depending on end connection and rating (e.g. A216 WCB / A352 LCC); bonnet steel, plug stainless steel; diaphragm and O-rings nitrile (NBR), with diaphragm material selected per the manual's Diaphragm Material Selection Information |
| Temperature range | Diaphragm -17 to 66 °C; body A216 WCB up to 71 °C, A352 LCC down to -30 °C (European version TS -20 to 71 °C / -30 to 71 °C) |
| Spring selection note | Red / black and similar springs are only recommended where inlet pressure may exceed 34.5 bar / 500 psig; the specific spring and outlet-range mapping is in official manual Table 2 |
| Integral shut-off option | EZROSX / EZROS2 include integral shut-off providing overpressure protection (OPSO), over- plus under-pressure (OPSO / UPSO), or dual overpressure protection |
| Applications | Natural gas, air and other non-corrosive gases (hydrogen service optional), used in city gate stations, district regulator stations, transmission and distribution networks and industrial / commercial lines; can serve as a high-capacity relief valve / backpressure regulator |
| Certifications and ordering | The related EZH / EZHSO series is officially stated to comply with PED 2014/68/EU Category IV (see D103680X012); the specific EZR certifications and complete ordering model (bore, rating, pilot, shut-off, materials) are subject to the nameplate / purchase order or the official selection catalogue |
Sources: the knowledge-base documents 'Fisher Regulator Technical Data Supplement 01 - Regulators / Reducers (General and Gas)' (entry_id 331cddb249cd4242b79bd47ff2cce835) and 'Fisher Regulator Technical Data Supplement 03 - Backpressure / Relief / Vent Valves' (entry_id 6f3352eff6e343a4a8d0151fc942112e), Product Materials space; based primarily on the Fisher official instruction manuals D102600X012 / D103681X012, the EZR Series Pressure Reducing Regulator Bulletin and Bulletin 71.4:EZR (emerson.com). The two volumes corroborate each other on body sizes, pressures, Cg, materials and relief capability. The arrival text only states 'EZR series' and gives no bore, connection, pilot or shut-off configuration; items not listed in the manuals are flagged honestly and no values are assumed.
IV. Related Models
| Item | Specification |
|---|---|
| EZH / EZHSO series | Fisher high-pressure pilot-operated pressure reducing regulators for high-pressure transmission, city gates, large-capacity distribution and power plants; used with a PRX/120-AP pilot (outlet 30 to 80 bar) and Type SA/2 pilot supply filter, compliant with PED 2014/68/EU Category IV (D103680X012) |
| EZL series | Fisher low-pressure pilot-operated reducer (D103091X012) with cast-iron CL125 FF / steel CL150 RF bodies, maximum body pressure 290 psig / 20 barg, minimum operating differential approx. 2.9 psid, NBR / FKM elastomers, for low-pressure applications |
| 133H series | Direct-operated (non-pilot) gas pressure reducing regulator with a 1.5 to 10 psig outlet and 2 in body; its construction and flow rating are completely different from the pilot-operated EZR and specifications must not be interchanged |
| EZR relief / backpressure configuration | With a relief pilot fitted, the EZR serves as a high-capacity relief valve / backpressure regulator (Bulletin 71.4:EZR), typically for overpressure protection at city gate and district stations; its pilot configuration differs from the pressure-reducing duty |
| Fisher 61 series pilot | Fisher pilot used with 1098-EGR, EZL and other pilot-operated reducers (its counterpart is used with the 99 series regulator), loading the actuator diaphragm by reducing inlet pressure to drive the main valve; a different model from the 161 / PRX pilots used on the EZR |
V. Selection Guide & Common Models
Selection guide:Selection starts with the medium and pressure rating: the EZR handles natural gas, air and other non-corrosive gases (hydrogen service optional); choose the pilot according to inlet pressure (up to approx. 72.4 bar nominal, depending on ASME rating and body size) and the required outlet range - 161AY (6 in w.c. to 7 psig), 161EB (5 to 350 psig), 161EBH (250 to 700 psig) or the PRX series - and check the corresponding 0.35 to 69 bar setpoint range. Then verify the NPS 1 to 6 (DN 25 to 150) body size, CL150/300/600 RF or PN 16B/25B/40B flanges, external 1/4 in NPT sensing line, Cg table against flow demand, temperature (diaphragm -17 to 66 °C), whether integral shut-off (OPSO / UPSO) is required, whether a relief / backpressure duty is intended, and the spring material note where inlet may exceed 500 psig. No single Cv is given by Emerson, so flow must be checked by body size and trim against manual Table 4 or with Emerson; the complete ordering model is subject to the nameplate / purchase order or the official selection catalogue. Please feel free to inquire for an item-by-item check against your service conditions.
Common models:This arrival: the Fisher EZR series pilot-operated pressure reducing regulator (pressure regulating valve), NPS 1 to 6 / DN 25 to 150. Parameters come from the Fisher official instruction manuals D102600X012 / D103681X012 and Bulletins recorded in the knowledge base, for selection verification only, not guaranteed values; the arrival note gives no bore, connection, pilot or shut-off configuration, so the specific configuration is subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文