TopWorx DXP / TXP / TXS Valve Position Switches - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the TOPWORX DXP-0H0GN4B / TXP-M20FLPM / TXP-N20GLPM00000N004 / TXS-L2CFLPM / TXS-N20GLPM00000N004 limit switches and discrete valve controllers. TopWorx is a brand of Emerson Process Management. This arrival spans two distinct series platforms: the DXP belongs to the D-series discrete valve controller (digital valve controller), while the TXP/TXS belong to the T-series compact direct-mount valve position feedback switches / limit switches; the TXP has a tropical-aluminium enclosure and the TXS a 316 stainless-steel enclosure, with identical Ex ratings. The Ex classification is determined by the third character 'zone classification' of the ordering code, not by the enclosure series letter: code 0 is intrinsic safety Ex ia IIC T4 and code C is flameproof Ex d IIC, which are strictly distinguished and must never be interchanged. The character-by-character decoding and parameters below are taken from the knowledge-base document TOPWORX and GO Switch Selection Rules Manual, for selection and spare-part verification.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | TOPWORX (a brand of Emerson Process Management) |
| Arrival models and series | DXP-0H0GN4B (D-series discrete valve controller, tropical aluminium); TXP-M20FLPM and TXP-N20GLPM00000N004 (T-series, tropical aluminium); TXS-L2CFLPM and TXS-N20GLPM00000N004 (T-series, 316 stainless steel) |
| Positioning | Discrete valve controllers and limit switches for on/off valve control and position monitoring, for rotary and linear actuators, with dry contacts, GO Switch, mechanical switches, proximity switches, NAMUR sensors or 4-20 mA transmitters, supporting FF, DeviceNet, AS-i, Profibus and HART protocols |
| Three series strictly distinguished | DXP (D-series) = world-class discrete valve controller, highest Ex rating (IIC), can carry pilot valves/spool valves/Cv options, up to 6 mechanical switches, DXS supports SIL-3 ESD; TXP (T-series) = compact direct-mount switchbox (tropical aluminium), no bracket required, up to 4 sensors, no pilot valve; TXS (T-series) = same construction as TXP but with a 316 stainless-steel enclosure |
| Determining factor for Ex rating | The Ex classification is set by the third character 'zone classification' of the ordering code: 0 = intrinsic safety Ex ia IIC T4/T6; 1 = flameproof Ex d IIB (Ex d IIB+H2 for DXP); C = fireproof Ex d IIC (non-pilot versions only); 2 = non-incendive Ex nA IIC; G = general purpose; W = no certification. It is independent of the enclosure series letter T/D or the P/S suffix |
| Source status | Character-by-character decoding is based on the coding tables in the knowledge-base document TOPWORX and GO Switch Selection Rules Manual; a few combined codes (e.g. 0H, N2) are not spelled out in the manual and are marked as subject to the original ordering code/nameplate, with no values assumed |
III. Technical Data
The character-by-character decoding and parameters below are transcribed item by item from the knowledge-base document TOPWORX and GO Switch Selection Rules Manual (entry_id bab2fc006bc046bb9d206dcaa897857e, Product Selection Rules space), based on the TopWorx Discrete Valve Controller product manual (TOPWORX.pdf, 32 pages) and the Chinese GO Switch product manual (20 pages). The coding structures follow sections 1.3.2 (D-series, 12 positions), 1.4.3 (T-series, 12 positions) and the zone-classification/sensor tables in sections 1.3.3/1.4.2; the Ex-misconception correction follows Part Four of the manual (supplement dated 2026-10-09). Pricing and arrival corroboration come from the Topworx-GOSWITCH Switch Price Sheet and purchasing cost records. Combined codes not spelled out in the manual are flagged honestly as subject to the original ordering code/nameplate, with no values assumed.
| Item | Specification |
|---|---|
| DXP-0H0GN4B decoded | DXP = D-series tropical-aluminium discrete valve controller; in suffix 0H0GN4B: 3rd position zone classification 0 = intrinsic safety (Ex ia IIC T4/T6); 4th position G = 90-degree green-open/red-close visual display; 5th position N = NAMUR 304 stainless-steel shaft; 6th position 4 = (2)3/4"NPT + (2)1/2"NPT conduit entries; 7th position B = nitrile O-ring. The leading combined code 0H (bus/sensor) is not spelled out in the manual and is subject to the original ordering code/nameplate |
| TXP-M20FLPM decoded | TXP = T-series tropical-aluminium direct-mount switchbox; M2 = (2) mechanical SPDT switches (15 A/120 VAC, zone classification cannot be 2); 0 = zone classification 0 intrinsic safety Ex ia IIC T4 (-50 to 85 C); F = flat knurled indicator; L = 1" extended linear shaft (TXP/TXS only); P = (2)1/2"NPT conduit entries; M = silicone O-ring |
| TXP-N20GLPM00000N004 decoded | TXP = tropical aluminium; 0 = zone classification 0 intrinsic safety Ex ia IIC T4; G = 90-degree green-open/red-close visual display; L = 1" extended linear shaft; P = (2)1/2"NPT conduit entries; M = silicone O-ring; the tail 00000N004 covers subsequent pilot/spool/Cv/manual/certificate extension positions. The leading combined code N2 is not listed in the manual's sensor table and is subject to the original ordering code/nameplate |
| TXS-L2CFLPM decoded | TXS = T-series 316 stainless-steel enclosure; L2 = (2) sealed GO Switch SPDT dry contacts (4 A/120 VAC, 3 A/24 VDC, non-pilot versions only); C = zone classification C fireproof Ex d IIC (flameproof, non-pilot TXP/TXS only); F = flat knurled indicator; L = 1" extended linear shaft; P = (2)1/2"NPT conduit entries; M = silicone O-ring |
| TXS-N20GLPM00000N004 decoded | TXS = T-series 316 stainless-steel enclosure; all other configuration positions are the same as TXP-N20GLPM00000N004, with 3rd-position zone classification 0 = intrinsic safety Ex ia IIC T4; tail extension 00000N004. The only difference from the TXP version is the enclosure material (316 stainless steel vs tropical aluminium); the Ex rating is identical |
| Ex classification strictly distinguished (red line) | Code 0 = Ex ia IIC T4/T6 intrinsic safety (TXP/TXS, safety barrier required for IS loops); code C = Ex d IIC flameproof (non-pilot versions only, e.g. TXS-L2CFLPM); DXP code 1 = Ex d IIB+H2 flameproof. Ex ia intrinsic safety is not Ex d flameproof and must never be interchanged; the Ex rating is set by the 3rd position, not by the enclosure letter T/D or the P/S suffix |
| TXP versus TXS | Both belong to the T-series with the same coding structure and the same Ex rating; the only difference is enclosure material: TXP = tropical aluminium (light, low cost, corrosion-resistant coating), TXS = 316 stainless steel (highest corrosion resistance, Ex IIC). Therefore TXP-N20GLPM and TXS-N20GLPM are not different Ex ratings but different enclosure materials |
| DXP versus TXP/TXS | DXP (D-series) requires a mounting bracket, can carry pilot/spool/Cv options, up to 6 mechanical switches, and DXS supports SIL-3 ESD; TXP/TXS (T-series) mount directly to ISO/NAMUR without a bracket, cannot carry a pilot valve, up to 4 sensors, with no SIL option. Selection depends on mounting/pilot/sensor count/SIL, never on Ex rating |
| Enclosure materials and protection | TXP = tropical aluminium, TXS = 316 stainless steel, DXP = tropical aluminium; T-series is II2GD, IP66/67, NEMA Type 4X; extreme environments -60 to +80 C; T-series features include TwistSet cam adjustment, stainless-steel shaft and fasteners, and up to 4 conduit entries |
| Sensors and switch ratings | M2/M4/M6 = mechanical SPDT (15 A/120 VAC); L2/L4 = sealed GO Switch SPDT (4 A/120 VAC, 3 A/24 VDC, intrinsically safe); E2/E4 = inductive NAMUR (p+f NJ2+V3-N, 8 VDC); PN/PS = proximity switches (1 A/250 mA max); P2 = 3 A proximity; X/H = 4-20 mA transmitter (HART, 8.5-34 VDC) |
| Visual display / shaft / conduit / O-ring | Visual display: G = 90-degree green-open/red-close, B = 90-degree black-open/yellow-close, Y = 90-degree yellow-open/black-close, F = flat knurled indicator (TXP/TXS only); shaft: N = NAMUR 304, L = 1" extended linear shaft (TXP/TXS only); T-series conduit entries: P = (2)1/2"NPT, M = (2)M20, E = (2)3/4"NPT, 3 = (4)M20, 4 = (2)3/4"NPT + (2)1/2"NPT; O-ring: M = silicone (T-series), D-series B = nitrile/S = silicone/E = EPDM/V = fluorocarbon |
| Electrical interfaces and protocols | Conduit entries 1/2", 3/4" NPT / M20 / M25 (up to 4), wiring via terminals, leads, cables, quick-disconnect (Micro/Mini Change, 3/4/5/7 pins) and submersible connectors; supports dry-contact switching, FF, DeviceNet, AS-i, Profibus DP, HART/4-20 mA and WirelessHART |
| Option compatibility limits | AS/DN/ES bus cannot use zone classification 0; M2/M4 mechanical switches cannot use zone 2; L2 only for non-pilot versions; PB requires zone 1/C/W; Ex Group I A/B must be sealed; DXP fireproof C type requires conduit entry E or M. Verify compatibility item by item before placing a combined order |
Sources: the knowledge-base document TOPWORX and GO Switch Selection Rules Manual (entry_id bab2fc006bc046bb9d206dcaa897857e, Product Selection Rules space), based primarily on the official TopWorx Discrete Valve Controller manual (TOPWORX.pdf, 32 pages) and the Chinese GO Switch product manual (20 pages). The D-series 12-position code, T-series 12-position code, zone classification (0 intrinsic safety / 1, C flameproof / 2 non-incendive / G general purpose / W no certification) and sensor tables are transcribed item by item; Part Four (supplement dated 2026-10-09) explicitly corrects the misconception that the enclosure series letter determines the Ex rating. The Topworx-GOSWITCH Switch Price Sheet (entry_id a1a892489fad45138fd1ed52bfadd970) and purchasing cost records (entry_ids 666b58c007d14314b19751831e12a61e and f714d1009ce04d0fabb551529578c647) contain purchase entries such as DXP-0H0GN4B that corroborate the arrival models. Combined codes not spelled out in the manual are flagged honestly; no values are assumed.
IV. Related Models
| Item | Specification |
|---|---|
| DXP-0H0GNEB | Same D-series discrete valve controller, zone classification 0 intrinsic safety, conduit entry E = (2)3/4"NPT, distinct from the arriving DXP-0H0GN4B whose entry 4 = (2)3/4"NPT + (2)1/2"NPT; listed in both the price sheet and purchasing records |
| TXP-M21GNPB1A1 | Knowledge-base ordering example, also a T-series tropical-aluminium unit like the TXP-M20FLPM, but with zone classification 1 = flameproof Ex d IIB, sensor M2, shaft N, entry P, O-ring B and pilot valve 1; used to contrast 0 intrinsic safety with 1 flameproof configurations |
| TXS-ASCGNPM1A1 | Knowledge-base T-series ordering example: 316 stainless steel, AS-i bus (AS), zone classification C = flameproof Ex d IIC, display G, shaft N, entry P, O-ring M; also flameproof like TXS-L2CFLPM but with a different bus/sensor |
| DXS series (316 stainless-steel version of DXP) | The 316 stainless-steel enclosure model within the D-series, supporting SIL-3 ESD partial-stroke testing (PST); a different platform from the T-series TXS and not interchangeable |
| TVA (T-series engineering-resin version) | T-series composite-resin switchbox, intrinsic safety/general purpose, Ex ia IIC T4 (II2G, -40 to 60 C), zone classification must be W or 0; different from the metal-enclosure TXP/TXS |
| GO Switch L2 / Z2 proximity switches | Common dry-contact sensors inside TOPWORX switchboxes: L2 = sealed SPDT, Z2 = sealed DPDT, 4 A/120 VAC, 3 A/24 VDC, intrinsically safe; the TXS-L2CFLPM is configured with L2 |
V. Selection Guide & Common Models
Selection guide:Selection starts with the series platform: choose the D-series for a discrete valve controller with pilot/spool/Cv options, up to 6 mechanical switches or SIL-3 ESD (DXS); choose the T-series (TXP tropical aluminium / TXS 316 stainless steel) for a compact direct-mount ISO/NAMUR valve position feedback switch requiring no bracket. Then configure character by character: 2nd position bus/sensor (L2, M2, E2, AS, FF, etc.), 3rd position zone classification (0 intrinsic safety Ex ia / 1, C flameproof Ex d / 2 non-incendive / G general purpose), 4th position visual display, 5th position shaft (N/L), 6th position conduit entry, 7th position O-ring, and the subsequent pilot/spool/Cv/manual/certificate positions. Always check Ex by the 3rd position and never infer it from the T/D series or P/S suffix: in this batch the TXS-L2CFLPM is classification C, Ex d IIC flameproof, while the others are classification 0, Ex ia IIC T4 intrinsic safety; Ex ia and Ex d must not be interchanged. Note compatibility limits such as L2 only for non-pilot versions, M2 not for zone 2, and AS/DN/ES not for zone 0. A few combined codes (0H, N2) and the tail extension positions are subject to the original ordering code/nameplate. Please feel free to inquire for an item-by-item check against your duty.
Common models:This arrival: TOPWORX DXP-0H0GN4B (D-series discrete valve controller), TXP-M20FLPM, TXP-N20GLPM00000N004, TXS-L2CFLPM and TXS-N20GLPM00000N004 (T-series valve position feedback switches / limit switches). The DXP and TXP/TXS belong to different series platforms; the TXP (tropical aluminium) and TXS (316 stainless steel) differ only in enclosure material with the same Ex rating; the TXS-L2CFLPM is Ex d IIC flameproof while the other classification-0 units are Ex ia IIC T4 intrinsic safety, strictly distinguished. Parameters come from the knowledge-base TOPWORX and GO Switch Selection Rules Manual, for selection and spare-part verification only, not guaranteed values. The specific configuration is subject to the nameplate/purchase order or the original ordering code, and combined codes not spelled out in the manual are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文