Samson 3730-4 Stainless Steel Valve Positioner 1000000411007009 - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Samson Type 3730-4 stainless-steel valve positioner (article code 3730-4 1000000411007009). The 3730-4 is a distinct sub-model of the 3730 family using a 16-digit grouped article code; its communication is bus-powered PROFIBUS-PA (IEC 61158-2), not a 4-20 mA/HART device (the HART version is the 3730-3 and must not be confused with this model). Checking digit by digit against the official article-code table: digit 10 = 1 denotes the stainless-steel housing (1.4581), digit 1 = 1 denotes ATEX intrinsic safety Ex ia, the trailing 009 corresponds to CCC Ex intrinsic-safety certification, digit 8 = 4 denotes EXPERTplus diagnostics and digit 13 = 7 denotes the additional vent hole. The data are taken from the knowledge-base document "SAMSON Smart Valve Positioner Technical Data and Model Coding Rules" (entry_id df754f4751924cb0a1d456b48cd55428, a 23-page full position-by-position table) and the official SAMSON data sheet T 8384-4 EN (entry_id c7a4dbb863694ba9bdbcc7a4312289e9), for selection and spare-part verification only.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | SAMSON (SAMSON AG, Germany; an independent automation brand) |
| Model | Type 3730-4 smart electropneumatic valve positioner with LCD and rotary pushbutton, PROFIBUS-PA communication, bus-powered (article code 1000000411007009) |
| Positioning | A distinct bus sub-model of the 3730 family (alongside the non-communicating 3730-0/1/2, the 3730-3 HART and the 3730-5 FF); microprocessor-controlled, it compares the set point transmitted cyclically over PROFIBUS-PA with the valve travel and issues a signal pressure, with integrated EXPERTplus valve diagnostics (T 8389) |
| Important protocol clarification | The 3730-4 is PROFIBUS-PA (IEC 61158-2 / IEC 61784), bus-powered with a bus digital set point; the 4-20 mA two-wire loop with HART belongs to the 3730-3 and does not apply to this model, which must not be described as a HART device |
| Arrival designation | The arrival note marks a "stainless-steel valve positioner", corroborated by housing-material digit 10 = 1 (stainless steel 1.4581); the complete ordering configuration is subject to the nameplate / purchase order |
| Source status | The knowledge base contains a dedicated technical compilation based on the official data sheets T 8384-4 EN and T 8384-3 and the SAMSON catalogue; digit-by-digit decoding follows the official article-code table, and items not listed in the available documents are flagged honestly with no values assumed |
III. Technical Data
The technical data are taken from the official SAMSON data sheet "Type 3730-4 Electropneumatic Positioner, T 8384-4 EN" (knowledge-base entry_id c7a4dbb863694ba9bdbcc7a4312289e9, including Table 1 technical data, Table 2 explosion-protection certificates and the Article code table). The digit-by-digit decoding is cross-checked against the knowledge-base document "SAMSON Smart Valve Positioner Technical Data and Model Coding Rules" (entry_id df754f4751924cb0a1d456b48cd55428, a 23-page full position table) and the official T 8384-5 article-code table for the CCC Ex 009 designation; the CCC Ex certificate number also appears in T 8384-4 EN Table 2. Note: the article code on the received goods is 3730-4 1000000411007009, and the official table requires digit 4 to be mandatorily 0 (PROFIBUS identifier); any form such as "10010004..." conflicts with that rule, and the nameplate / purchase order and the official selection tool govern. Items not listed in the available documents are flagged honestly; no values are assumed.
| Item | Specification |
|---|---|
| Article code digit-by-digit (16 digits) | 3730-4 1000000411007009 → digit 1 = 1: ATEX intrinsic safety Ex ia; digit 2 = 0: no inductive position switch; digit 3 = 0: no solenoid valve; digit 4 = 0: mandatory PROFIBUS identifier; digit 5 = 0: no external position sensor; digit 6 = 0: fixed; digit 7 = 0: no binary input; digit 8 = 4: EXPERTplus diagnostics; digit 9 = 1: fixed (PROFIBUS-PA version marker); digit 10 = 1: stainless-steel housing; digits 11/12 = 0: fixed; digit 13 = 7: additional vent hole; digits 14/15/16 = 0/0/9: special version 009 (CCC Ex intrinsic safety) |
| Communication and power supply | PROFIBUS-PA, transmission technology per IEC 61158-2 / IEC 61784, bus-powered field device (FISCO); certified to PROFIBUS-PA Profile 3.01 and fulfilling the mandatory requirements of Profile 3.02, with automatic ID adaptation to Profile 2.0/3.0; integratable via DTM (FDT 1.2) and SIMATIC PDM/EDD. Supply 9 to 32 V DC over the bus line, maximum operating current 15 mA, additional current in case of error 0 mA; limits in the type examination certificate additionally apply to explosion-protected versions |
| Input signal and protocol clarification | Set point comes from the bus, plus one binary input for DC voltage signals to report process information over PROFIBUS-PA; local commissioning uses the SAMSON SSP interface and TROVIS-VIEW with database module 3730-4. The 4-20 mA two-wire loop with HART belongs to the 3730-3 and does not apply to this model, which must not be confused with it |
| Explosion protection (digit 1 = 1) | ATEX: II 2G Ex ia IIC T6 Gb; II 2D Ex ia IIIC T80°C Db (EC type examination certificate PTB 04 ATEX 2109). Further certificates include CSA, FM, IECEx, TR CMU 1055, CCoE and ERL Ex (T 8384-4 EN Table 2). Note that intrinsic safety Ex ia is not flameproof Ex d; where Ex d is required, the 3731 series should be selected |
| CCC Ex certification (trailing digits 009) | Special version 009 together with digit 1 = 1 forms 1009, corresponding to CCC Ex Ex ia IIC T4~T6 Gb (certificate no. 2020322307002425, see T 8384-4 EN Table 2 and the official article-code table); certificate validity is subject to the documents delivered with the goods |
| Housing material (digit 10 = 1) | Stainless-steel housing 1.4581 (standard aluminium code is 0, die-cast aluminium EN AC-AlSi12(Fe); external parts stainless steel 1.4404/316L); approximate weight: aluminium version approx. 1.0 kg, stainless-steel version approx. 2.2 kg. The arrival note "stainless steel" agrees with the code |
| Diagnostics (digit 8 = 4) | EXPERTplus (firmware version K 2.xx) with integrated diagnostics for control valves (T 8389) and NAMUR NE 107 classified status alarms; code 2 is EXPERT+ (K 1.xx), while this arrival is code 4, i.e. EXPERTplus |
| Additional equipment (digits 2/3/5/7 = 0) | No inductive limit contact (1 = SJ2-SN NC contact), no solenoid valve (4 = with 24 V DC), no external position sensor and no binary input (01 = floating contact) |
| Special application (digit 13 = 7) | With additional vent hole; other options: 0 = without, 1 = version compatible with paint, 2 = exhaust port with 1/4-18 NPT thread, 6 = additional vent hole with VDI/VDE 3847 adapter |
| Supply air and air quality | Supply air 1.4 to 7 bar (20 to 105 psi), air quality per ISO 8573-1:2001: solids Class 4, oil Class 3, humidity and water Class 3; pressure dew point at least 10 K below the lowest expected ambient temperature; signal pressure output 0 bar up to the supply-pressure capacity |
| Travel and mounting | Linear travel 3.6 to 30 mm (direct attachment to Type 3277 actuator / NAMUR IEC 60534-6) or 3.6 to 300 mm (VDI/VDE 3847); opening angle 24 to 100 degrees (VDI/VDE 3845); adjustable within the initialized travel and limitable to 1/5 maximum; any mounting position, but not suspended |
| Control performance | Characteristics: linear, equal percentage, reverse equal percentage and user-defined (butterfly valve, rotary plug valve, segmented ball valve), deviation <= 1%; hysteresis <= 0.3%; sensitivity <= 0.1%; reversible direction of action; air consumption approx. < 110 l/h; temperature influence <= 0.15%/10 K, no influence of supply air |
| Protection, temperature and electrical connections | Degree of protection IP 66 / NEMA 4X; permissible ambient temperature -20 to +80 degrees C for all versions and -45 to +80 degrees C with metal cable gland; one M20 x 1.5 cable gland for 6 to 12 mm clamping range plus a second M20 x 1.5 threaded connection; screw terminals for 0.2 to 2.5 mm2 wire; CE marking, EMC per EN 61000-6-2/-6-3, EN 61326-1 and NAMUR NE 21 |
| Functional safety | With emergency venting at 0 V set point and an optional solenoid valve, the pilot valve has the systematic capability per IEC 61508 and can be used under IEC 61511 up to SIL 2 (single device, HFT = 0) and SIL 3 (redundant configuration, HFT = 1) in safety-instrumented systems |
Sources: (1) the knowledge-base document "SAMSON Smart Valve Positioner Technical Data and Model Coding Rules" (entry_id df754f4751924cb0a1d456b48cd55428, Product Selection Rules space, a 23-page full position table containing section 3.4.2 on the 3730-4 positions and verified examples); (2) the official SAMSON data sheet "Type 3730-4 Electropneumatic Positioner, T 8384-4 EN" (knowledge-base entry_id c7a4dbb863694ba9bdbcc7a4312289e9, PDF in the Product Materials space, with Table 1 technical data, Table 2 explosion-protection certificates and the Article code table); (3) the official T 8384-5 EN article-code table (knowledge-base entry_id 4bb45e7b4cc64ddaa952598f8e4ab3fe) used to cross-check the CCC Ex 009 designation. The three sources corroborate each other: the 3730-4 is a bus-powered PROFIBUS-PA device with a 16-digit code, digit 4 mandatorily 0, housing code 1 = stainless steel 1.4581, digit 8 = 4 for EXPERTplus, and the certificates PTB 04 ATEX 2109 and CCC Ex 2020322307002425. Items not listed or marked pending in the available documents are flagged honestly; no values are assumed.
IV. Related Models
| Item | Specification |
|---|---|
| 3730-3 (HART version) | Also a 16-digit-code member of the 3730 family, but with a 4-20 mA two-wire loop plus HART and housing code 1 = stainless steel 1.4408; the arrived 3730-4 is a bus-powered PROFIBUS-PA model, and the two protocols and code structures must not be interchanged (T 8384-3; knowledge-base entry ac94907665084332a88025ab9e8994b3) |
| 3730-5 (FOUNDATION Fieldbus version) | Also a bus-type 16-digit-code model using FF, with explosion protection occupying 4 digits (P1 + P14-P16) and a leakage-sensor option, likewise with digit 4 mandatorily 0; different from the PROFIBUS-PA of the 3730-4 (T 8384-5 EN) |
| 3730-0 / 3730-1 / 3730-2 (non-communicating basic versions) | Entry-level members of the 3730 family without a fieldbus, where digit 4 is not forced to 0; selection starts by deciding whether HART, PA or FF communication is needed, then by explosion protection and housing (T 8384-0 / T 8484-1) |
| 3731-3 / 3731-5 (flameproof Ex d versions) | The Ex d flameproof counterparts of the corresponding 3730 models, with 15-digit codes and cast-aluminium or stainless-steel housings for Zone 1 hazardous areas; the arrived 3730-4 is intrinsically safe Ex ia / Ex nA only, not a flameproof device (T 8387-3 / T 8387-5) |
| 3725 (basic smart positioner) | A 10-digit-code, 4-20 mA two-wire, intrinsically safe Ex ia positioner without a fieldbus, suited to cost-sensitive duties; different positioning and communication from the 3730 family (T 8394 EN) |
| 3730-6 (pressure-monitoring version) | A special design derived from the 3730-3 with a 14-digit code, supply/output pressure monitoring and an Ex d[ja] option (T 8384-6); a different functional role from the bus-type 3730-4 |
V. Selection Guide & Common Models
Selection guide:Selection starts with the communication protocol: the 3730-4 is for bus-powered PROFIBUS-PA duties; for a 4-20 mA plus HART loop choose the 3730-3, for FOUNDATION Fieldbus choose the 3730-5, for a non-communicating basic model choose the 3730-0/1/2, and where flameproof Ex d is required choose the 3731 series — intrinsic safety Ex ia must never be confused with flameproof Ex d. Next check explosion protection: digit 1 = 1 is ATEX intrinsic safety Ex ia IIC T6 Gb and the trailing 009 is CCC Ex Ex ia IIC T4~T6 Gb; verify each item against T 8384-4 EN Table 2 according to the zone certification required. Then set the housing and options: digit 10 = 1 is stainless steel 1.4581 (standard aluminium is 0), digit 8 = 4 is EXPERTplus, digit 13 = 7 is the additional vent hole, and the remaining positions cover inductive limit contacts, solenoid valves, external position sensors and binary inputs as actually needed. Also verify bus power 9 to 32 V DC / 15 mA, supply air 1.4 to 7 bar with ISO 8573-1 quality, travel 3.6 to 300 mm, IP66/NEMA 4X and -20 to +80 degrees C (-45 to +80 degrees C with metal cable gland). The complete 16-digit article code is finally governed by the official SAMSON selection/ordering tool and the nameplate and purchase order delivered with the goods; items not listed in the available documents are not assumed. Please feel free to inquire for an item-by-item check against your service conditions.
Common models:This arrival: the Samson Type 3730-4 stainless-steel valve positioner, article code 3730-4 1000000411007009 (bus-powered PROFIBUS-PA, not a 4-20 mA/HART device), with housing digit 10 = 1 for stainless steel 1.4581 agreeing with the arrival note. The parameters come from the official SAMSON data sheet T 8384-4 EN and the knowledge-base selection rules (entry_id df754f4751924cb0a1d456b48cd55428), for selection and spare-part verification only, not guaranteed values. The specific configuration is subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文