Fisher 912-264 LP-Gas Pressure Regulator - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Fisher 912 Series pressure-reducing regulator, model 912-264. The 912 Series comes from Fisher (the brand now belongs to Emerson) and is a family of direct-operated, spring-loaded pressure-reducing regulators that hold pressure by the outlet pressure acting directly on the diaphragm against the adjusting spring, with limited-capacity internal relief; it is commonly used for single-stage low-pressure (in. w.c. class) LP-Gas/gas service, or the high-pressure 912H variant. The arrival record (2026-03-27, item name "reducing valve", quantity 40 sets) designates 912-264 as another ordering configuration on the 912 platform, distinct from the same-batch 912-101. The 912-264, 912-101 and 912N-1070-166658 are three different configurations and must not be interchanged for ordering or spare parts. The specifications below are compiled from the knowledge-base document "Technical Data Supplement 01 - Regulators / Pressure-Reducing Regulators (General and Gas)" and the Emerson official manuals it cites, for selection verification; the specific body size, spring range and connections are subject to the nameplate / purchase order.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | FISHER (a brand of Emerson) |
| Model | 912-264, part of the Fisher 912 Series of direct-operated, spring-loaded pressure-reducing regulators |
| Positioning | Small self-operated gas reducing regulator: outlet pressure acts on the diaphragm directly against the adjusting spring, with limited-capacity internal relief to suppress overpressure; internal pressure sensing; for single-stage low-pressure supply and industrial regulation of LP-Gas, natural gas and other gases |
| Arrival designation | Purchase record dated 2026-03-27, item name "reducing valve", quantity 40 sets, unit price 360, lead time 4 weeks; designated as the 912 Series ordering configuration 912-264; the specific spring range / body size / connections are subject to the nameplate / purchase order |
| Distinction from 912-101 | The 912-264 and 912-101 are both 912 Series "reducing valve" arrivals at the same unit price but with different arrival dates and quantities (264: 2026-03-27 / 40 sets; 101: 2026-05-14 / 50 sets). The knowledge base does not list the body-size/spring/connection differences between them field by field, so no inference is made from the arrival note; the nameplate / purchase order governs |
| Distinction from 912N-1070-166658 | The 912N-1070-166658 belongs to the 912N branch (low/high-pressure dual-use, gray, non-UL-listed, multi-service industrial type), of which only 1 unit arrived; the 912-264 belongs to the main 912 Series reducing-valve configuration. The suffix 1070-166658 is a part/order number not decomposed digit by digit in the knowledge base |
| Source status | The knowledge base contains a dedicated technical compilation based on the Emerson official "Single and Second-Stage LP-Gas Regulators Instruction Manual" (June 1986) and the 912N manuals D450027T012 and D100317X012; items not listed are flagged honestly and no values are assumed |
III. Technical Data
The specifications below are taken from entries "No. 102 Fisher 912 Series Pressure-Reducing Regulator - LP-Gas" and "No. 22 Fisher 912N Series Regulator" in the knowledge-base document "Technical Data Supplement 01 - Regulators / Pressure-Reducing Regulators (General and Gas)", based primarily on the Emerson official "Single and Second-Stage LP-Gas Regulators Instruction Manual" (June 1986), the 912H/912N manual D450027T012, and the 912N Series Instruction Manual D100317X012 / Installation Guide D100317X014. Capacity and certification items not stated in the official manual are flagged as "per distributor page (unofficial/distributor)". The field-by-field ordering differences of the 912-264 are not listed in the available official materials and are subject to the nameplate / purchase order or the official manual, with no values assumed.
| Item | Specification |
|---|---|
| Operating principle | Direct-operated, spring-loaded: outlet pressure acts on the diaphragm directly against the adjusting spring; no external pilot supply is needed, being driven by the media's own pressure; with limited-capacity internal relief that vents excess pressure when the outlet rises above the set point and lifts the diaphragm off the relief seat |
| Applicable media | LP-Gas vapor, natural gas, air and other gases; the 912/912H types are for vapor/gas only and explicitly must not be used for liquid service |
| Pressure class | Maximum inlet pressure 250 psig (17.2 bar); emergency maximum outlet pressure approx. 20 psig (1.4 bar); inlet limited to 20 psig when used as a second stage |
| Outlet pressure and spring | Single-stage low-pressure type is commonly around 11 in. w.c. (27 mbar); industrial adjustable approx. 3 in. w.c. to 5 psi (per distributor page); select the spring part number per Table 1, with the 912N-HNRUL fixed 12-24 in. w.c. (30-60 mbar) as a family reference; the specific spring range of the 912-264 is subject to the nameplate / purchase order |
| Body and connections | Body with 1/4 in FNPT inlet and 1/4 or 3/8 in FNPT outlet (single-stage 912); part numbers vary with connection and port diameter (e.g. 3B782444042 is 1/4x3/8 NPT, Ø0.073"); the specific port combination of the 912-264 is subject to the nameplate / purchase order |
| Pressure sensing | Internal sensing (standard construction); spring-case vent with screen, some with a 1/8 in FNPT screened vent port |
| Flow coefficient | No Cv capacity table is stated in the official manual; capacity is expressed in propane-vapor BTU/hr, approx. 350,000 BTU/hr (approx. 320,000 with tailpiece, per distributor page); exact values per body size/spring from the manual or Fisher Catalog 12 |
| Overpressure protection limits | The internal relief is of limited capacity and serves only minor seat leakage/overpressure; it is not complete overpressure protection; external relief/limitation is required within approx. 3 psi (0.21 bar) differential above the outlet setting |
| Construction materials | Body zinc/aluminium etc. per model (the LPG 912N-HNRUL has a zinc body); diaphragm nitrile NBR; disc fluorocarbon FKM; spring case/vent screen 304 stainless steel; fulcrum rod 302 stainless steel; adjusting spring steel |
| Seat and sealing | Predominantly soft seating: NBR diaphragm with FKM disc; closing-cap gasket of composite material (recommended spare part); the diaphragm and disc/lever assembly can be replaced without removing the body from the line |
| Temperature range | -20 to 160 °F (-29 to 71 °C), depending on diaphragm/seat materials; NBR typically approx. -20 to 180 °F (per distributor page; the official manual governs) |
| Certifications | UL listed (912 single-stage low-pressure / 912H high-pressure); CRN certified; CE approval (per distributor Instrumart page, unofficial/distributor); the 912N is a non-UL-listed model |
| Installation note | Drip-lip vent resists rain, insects and ice; installation must comply with applicable codes such as NFPA 54/58; the media must be clean; confirm the specific installation orientation and setting direction with Emerson / Baoman |
Sources: the knowledge-base document "Technical Data Supplement 01 - Regulators / Pressure-Reducing Regulators (General and Gas)" (entry_id 331cddb249cd4242b79bd47ff2cce835, Product Materials space), with entries "No. 102 Fisher 912 Series Pressure-Reducing Regulator - LP-Gas" and "No. 22 Fisher 912N Series Regulator" transcribed item by item. Its primary bases are the Emerson official "Single and Second-Stage LP-Gas Regulators Instruction Manual" (emerson.com, June 1986), the 912H/912N manual D450027T012, the 912N Series Instruction Manual D100317X012 and Installation Guide D100317X014, with certain capacity/certification items relayed by distributors Instrumart and ManualZilla and marked unofficial. The arrival data (912-264, item name "reducing valve", quantity 40 sets, unit price 360, lead time 4 weeks, 2026-03-27) is corroborated by the knowledge-base document "Actual Purchase Cost Records through 2026-05-31" (entry_id 666b58c007d14314b19751831e12a61e, Price List space) together with the arrival note. This data comes from a knowledge-base hit; no web search was used. Items not listed or marked pending in the knowledge base are flagged honestly and no values are assumed.
IV. Related Models
| Item | Specification |
|---|---|
| 912-101 | Another 912 Series ordering configuration received in the same batch (purchase record 2026-05-14, item name "reducing valve", quantity 50 sets, same unit price as the 912-264). The knowledge base does not break out the body-size/spring/connection differences between 264 and 101 field by field; the two must not be interchanged and the nameplate / purchase order governs |
| 912N-1070-166658 | An ordering configuration of the 912N branch (purchase record 2026-04-22, item name "regulator", quantity 1). The 912N is a low/high-pressure dual-use, gray, non-UL-listed, multi-service industrial type for natural gas, propane, air etc.; the suffix 1070-166658 is a part/order number not decomposed digit by digit in the knowledge base and is subject to the nameplate / purchase order |
| 912H | High-pressure variant of the 912 Series, red, UL listed, for steam applications and not for liquid; it differs from the low-pressure positioning of the 912-264 in pressure class and color identification |
| 912N-HNRUL | A non-relieving compressed-gas/LPG fixed-setting type in the 912N family: zinc body, NBR diaphragm, FKM disc, outlet spring 12-24 in. w.c. (30-60 mbar), 1/4x3/8 NPT; a spring/material reference only, not the ordering number of this arrival |
| Fisher 64 / 67C Series | Also Fisher direct-operated high-pressure/LP-Gas regulators used at different pressure ranges; in the knowledge-base "Technical Data Supplement 01", the 64 Series is an adjustable high-pressure type and the 67C a 1/4" high-pressure LPG type, selected against the 912 platform by pressure range and media |
V. Selection Guide & Common Models
Selection guide:Selection first clarifies the duty of the 912-264: a 912 Series direct-operated, spring-loaded gas reducing regulator; check against the media (LP-Gas vapor/natural gas/air, not for liquid service), the maximum inlet of 250 psig (17.2 bar, inlet limited to 20 psig as a second stage) and the outlet setting (commonly around 11 in. w.c.). Then check the ports (1/4 in FNPT inlet, 1/4 or 3/8 in FNPT outlet) and select the spring range in the official manual Table 1 for the required outlet pressure; confirm that the internal relief is of limited capacity only and that external relief/limitation is required if the inlet can overpressure or exceed the downstream rating. For hazardous or code-governed service, check the applicable UL/CRN/CE scope and NFPA 54/58. Note especially that the 912-264, 912-101 and 912N-1070-166658 are different configurations whose differences are not broken out field by field in the knowledge base; ordering and spare parts must be confirmed against the nameplate / purchase order, with no values assumed. Please feel free to inquire for an item-by-item check against your media, body size and spring range.
Common models:This arrival: the Fisher 912 Series pressure-reducing regulator 912-264 (direct-operated, spring-loaded LP-Gas/gas reducing regulator), a different configuration from the same-batch 912-101 and 912N-1070-166658. Parameters come from the Emerson official LP-Gas regulator manual and the 912N manuals D450027T012 / D100317X012 recorded in the knowledge base, for selection and spare-part verification only, not guaranteed values. The specific configuration, body size, spring range and applicable certification scope are subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH