Masoneilan BR400 Volume Booster 1.03MPa - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Masoneilan BR400 volume booster, 1.03 MPa. The BR400 is a high-capacity pneumatic volume booster relay from GE Masoneilan (the brand now belongs to Baker Hughes), used to increase the stroking speed of large-volume diaphragm or piston actuators; the 1.03 MPa stated in the arrival note corresponds to the manual's maximum supply / signal pressure of 150 psi (10.3 bar). The BR400 and the BR200 are different models with different Cv, ports and weight, and their specifications must not be interchanged. The specifications below are taken from the original manufacturer's instruction manual GEA30642A recorded in the knowledge base, for selection and spare-part verification.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | MASONEILAN (formerly GE Masoneilan, now part of Baker Hughes) |
| Model | BR400 High Capacity Volume Booster Relay |
| Positioning | Purely pneumatic boosting accessory for diaphragm and piston actuators, used on control valves requiring fast stroke or large actuator volume; 1:1 input/output pressure ratio, with an adjustable internal bypass valve for stability on small signals |
| Difference from BR200 | The BR400 has a maximum supply Cv of 2.6 (BR200: 1.2), exhaust Cv of 2.4 (BR200: 1.2), 1/2" NPT or Rc supply/output ports (BR200: 1/4"), and an approximate weight of 1.4 kg (BR200: 0.7 kg). Maximum pressure and signal ports are the same for both |
| Arrival designation | The 1.03 MPa marked on the goods corresponds to the manual's maximum supply pressure of 150 psi (10.3 bar), not a rated working pressure; the specific ordering configuration is subject to the nameplate / purchase order |
| Source status | The knowledge base contains a dedicated Chinese technical compilation based on the original GE manual GEA30642A and the Masoneilan Condensed Catalog; parameters are transcribed from the originals. Neither manual nor catalogue provides a How to Order suffix code, so no part number is assumed |
III. Technical Data
The specifications below are taken from the GE document "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual", document no. GEA30642A (April 2014 edition; Table 1 specifications, pneumatic supply requirements, materials list and dimension drawings), with hazardous-area certifications and alternative temperature ranges supplemented from the Masoneilan Condensed Catalog. Neither the manual nor the catalogue provides an ordering-code table; items not listed in the available documents are flagged honestly and are subject to the nameplate / purchase order or the official manual, with no values assumed.
| Item | Specification |
|---|---|
| Maximum Cv (supply) | 2.6 (BR200: 1.2), giving higher flow capacity for larger actuators |
| Maximum Cv (exhaust) | 2.4 (BR200: 1.2) |
| Maximum supply pressure | 150 psi (10.3 bar, approx. 1.03 MPa); the 1.03 MPa marked on the goods is this upper limit, the same for the BR200 and BR400 |
| Maximum signal pressure | 150 psi (10.3 bar), the same as the maximum supply pressure |
| Input/output pressure ratio | 1:1; a rising input signal pushes the upper diaphragm and opens the pilot valve for supply flow, while falling signal opens the exhaust valve, with output pressure balanced against the input through the lower diaphragm; an internal bypass valve with lock screw provides stability at small or slowly changing signals |
| Operating temperature (standard) | -30 °C to +83 °C (-22 °F to +181 °F); low- and high-temperature options are also available |
| Operating temperature (low option) | -55 °C to +60 °C (-67 °F to +140 °F) |
| Operating temperature (high option) | 0 °C to +100 °C (32 °F to +212 °F) |
| Connections | Supply/output: 1/2" NPT or Rc (BR200: 1/4"); signal port: 1/4" NPT or Rc (same as the BR200) |
| Approximate weight and dimensions | Approx. 1.4 kg (3 lb); body diameter approx. Ø127 mm (5"), overall height approx. 119 mm (4.7"); the BR200 is 0.7 kg, Ø86 mm and 79.5 mm respectively |
| Main materials | Body and case: die-cast aluminium alloy; upper/lower diaphragms: chloroprene/polyester; seal plate, coil spring, plug, bypass valve plug, supply and signal filters: austenitic stainless steel; exhaust seat and seal guide: copper alloy; piston: glass-fibre-reinforced thermoplastic polyester |
| Air supply requirements | Clean, dry, oil-free instrument air per ANSI/ISA-S7.3 (R1981); dew point at least 10 °C (18 °F) below the minimum expected ambient temperature; particles filtered below 5 µm; oil content < 1 ppm; no corrosive contaminants or flammable/toxic gases |
| Installation | Mount as close to the actuator as possible, using a short 1/2" pipe union between the relay and actuator as both air connection and support; exhaust facing down is preferred, horizontal mounting is also acceptable; use an anaerobic sealant such as Loctite 542 on threads and do not use PTFE tape, to avoid debris entering the instrument |
| Hazardous-area certification and ordering code | GEA30642A lists no Ex certification; the Masoneilan Condensed Catalog lists ATEX, FM and CSA for the BR200/BR400 with an ambient range of -40 °C to +83 °C (slightly different from the IOM standard range; the final purchase confirmation governs). The volume booster is a purely pneumatic accessory, not an electrical Ex device. The manual notes that a stainless-steel BR400 version is available for marine/offshore use but gives no model suffix; the complete ordering model (ports, materials, certifications, options) is not listed in the available materials and is subject to the nameplate / purchase order or the official selection catalogue |
Sources: the knowledge-base document "Masoneilan BR200/BR400 Volume Booster Technical Data and Model Rules" (entry_id 6e6277a32a66405b80868c60fe3c7e1e, Product Selection Rules space), based primarily on the original GE document "BR200/BR400 High Capacity Volume Booster Relays Instruction Manual" GEA30642A (04/2014, user-supplied PDF) and supplemented by the Masoneilan Condensed Catalog (the Masoneilan brochure entry in the knowledge base's Product Materials space). Knowledge-base purchasing records (e.g. the 2025-11-17 entry "BR400 1/2 NPT, Cv 2.6, temperature -55 C to +60 C") corroborate the 1/2" ports, Cv 2.6, low-temperature option and the 1.03 MPa pressure ceiling stated in the arrival note. Items not listed or marked pending in the available documents are flagged honestly; no values are assumed.
IV. Related Models
| Item | Specification |
|---|---|
| BR200 | The smaller sibling in the same volume-booster series: maximum supply and exhaust Cv both 1.2, supply/output and signal ports both 1/4" NPT or Rc, approx. 0.7 kg, body approx. Ø86 mm; specifications must not be interchanged with the BR400 |
| BR400 stainless-steel (marine/offshore) version | GEA30642A mentions in one sentence that a stainless-steel version is available for marine/offshore applications but gives no model suffix; orders must be confirmed with Baker Hughes/Masoneilan and no part number is assumed here |
| Masoneilan 78-40 / 78-80 series | Masoneilan filter regulators and pneumatic control valves often paired with volume boosters and positioners; listed in the knowledge-base price sheet, with technical data subject to the official catalogue |
| Fisher 2625 / 65 series volume boosters | Alternative large-flow pneumatic boosters from another brand, compared in the knowledge-base documents "Fisher Volume Booster Technical Data Summary" and "FISHER Lock-up Valve Technical Data and Selection Rules"; selection requires item-by-item checks of Cv, ports and tight shut-off |
| ControlAir 6100 / 6500 / 6600 | US-made large-flow boosters supplied by Baoman, with EXIDA SIL 3 and EAC certifications for anti-surge and other high-flow duties; a different brand from the BR400, with non-interchangeable specifications |
V. Selection Guide & Common Models
Selection guide:Selection starts with the duty: the BR400 serves large-volume diaphragm or piston actuators requiring fast stroking; check supply Cv 2.6 and exhaust Cv 2.4 against the actuator volume and required stroke time, and distinguish it from the BR200 (Cv 1.2). Then confirm that pressures do not exceed 150 psi (10.3 bar, approx. 1.03 MPa), verify signal pressure and the 1:1 input/output relationship, select the temperature range (standard -30 to +83 °C, low -55 to +60 °C, high 0 to +100 °C), check the 1/2" NPT or Rc supply/output and 1/4" signal ports, the ISA/ISO instrument-air quality requirements and the installation orientation (exhaust preferably facing down). For hazardous areas, confirm the specific ATEX/FM/CSA certificates and zone classification with Baker Hughes/Masoneilan, and confirm the ordering designation of the stainless-steel version for marine/offshore service. Since the manual contains no How to Order suffix, the complete ordering code is subject to the nameplate / purchase order or the official selection catalogue. Please feel free to inquire for an item-by-item check against your actuator and service conditions.
Common models:This arrival: the Masoneilan BR400 volume booster (pneumatic volume booster relay), 1.03 MPa, a different model from the BR200. Parameters come from the original GE manual GEA30642A and the Masoneilan catalogue recorded in the knowledge base, for selection and spare-part verification only, not guaranteed values. The specific configuration is subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文