Emerson AMS Trex Communicator TREXLHPKLWS3S - Arrival & Data
This arrival, photographed in our warehouse: the Emerson AMS TREX field communicator TREXLHPKLWS3S, from the same classic first-generation TREX platform as the TREXCHPNAWS1 of the third batch (No. 1357). The key feature of this model is the leading L - the Device Communication Plus module (built-in ammeter to measure 4-20 mA loops and power the loop), a different configuration from the C module (HART + FF) of No. 1357. The knowledge base returned only purchasing and supply-capability records and no dedicated technical document for this model; parameters are taken from the official specification pages verified online for No. 1357 and the Emerson official SKU page rechecked in this batch, for selection and spare-part verification.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | Emerson (AMS asset-management software product line; Rosemount is its process-measurement brand, and this handheld belongs to the AMS TREX field-communicator line) |
| Category | AMS TREX device communicator (field communicator), a handheld field instrument with loop-check and diagnostic functions |
| Model | TREXLHPKLWS3S (classic first-generation TREX, L = Device Communication Plus module; distinct from the next-generation TREX 2 / TREX2LHPKLWS3S) |
| Ordering-code clues | TREX = TREX platform; L = Device Communication Plus module (with mA measurement and loop powering); the segments HPK and LWS3S are not decoded digit by digit on the official SKU page and are subject to the nameplate / purchase order or the official ordering guide |
| Core capabilities | Field diagnosis, configuration and calibration of HART / FF / Bluetooth devices; Loop Diagnostics, ValveLink Mobile valve diagnostics and Fieldbus segment diagnostics; the Device Communication Plus module supports a built-in ammeter for 4-20 mA measurement and loop powering (Power the Loop) |
| Generation distinction | Classic first-generation TREX (this arrival: 800 MHz ARM Cortex A8 / Windows Embedded Compact 2013 / Bluetooth 2.1); next-generation TREX 2 (1.2 GHz quad-core Cortex-A53 / new OS / 8x memory / NIST-traceable calibration). Specifications must not be interchanged |
| Source status | No dedicated technical document exists in the knowledge base; parameters were obtained online from official sources, including data verified for No. 1357 |
III. Technical Data
The specifications below apply to the classic first-generation AMS TREX (TREXLHPKLWS3S): an 800 MHz ARM Cortex A8 / NXP microprocessor, Windows Embedded Compact 2013, 2 GB + 32 GB flash and 512 MB RAM. This unit is the L configuration - the Device Communication Plus module (built-in ammeter to measure 4-20 mA and power the loop), distinct from the C module (HART + FF) of No. 1357. The redesigned AMS TREX announced in October 2025 (1.2 GHz quad-core, 8x memory, NIST-traceable calibration, added Bluetooth HART) is a different platform and its specifications must not be interchanged. Segments such as HPK and LWS3S are not decoded digit by digit on the official SKU page; they are marked as not listed in the available materials and are subject to the nameplate / purchase order or the official manual, without assumption.
| Item | Specification |
|---|---|
| Brand / model | Emerson; AMS TREX TREXLHPKLWS3S (classic first generation, L module = Device Communication Plus with mA measurement and loop powering) |
| Microprocessor | 800 MHz ARM Cortex A8 / NXP microprocessor |
| Memory and storage | Internal flash 2 GB NAND + 32 GB extended flash; RAM 512 MB DDR3 SDRAM |
| Display | 5.7 in (14.5 cm) colour VGA resistive touchscreen, adjustable brightness and glove-operable |
| Operating system | Windows Embedded Compact 2013 (the next-generation TREX 2 uses a new platform/OS; the official news release cites 8x memory, a quad-core processor and NIST-traceable calibration) |
| Communication protocols | HART, FOUNDATION Fieldbus (FF); multi-vendor field devices via EDDL; Bluetooth 2.1, Wi-Fi and active NFC; connects to more than 2,500 Emerson and third-party field instruments |
| Communication module L | Device Communication Plus module: HART/FF terminals with a built-in ammeter to measure 4-20 mA loops and power the loop (Power the Loop), supporting Loop Diagnostics, inline valve configuration and testing; hot-swappable and intrinsically safe (IS) |
| Weight | Approximately 2.9 lbs (1330 g) |
| Battery and charging | Rechargeable lithium-ion power module; 8+ hours of typical use; charge time 3-4 hours |
| Operating temperature | -20 to +55 degC (-4 to +131 degF) |
| Enclosure and shock | IP54; tested to survive a 1 m all-sides-and-corners drop onto concrete; meets global Intrinsic Safety (IS) standards for use in hazardous areas |
| Functional applications | Field Communicator, ValveLink Mobile, WirelessHART Provisioning, Loop Diagnostics, Fieldbus Diagnostics, calculator and PDF viewer apps; automatic synchronisation with AMS Device Manager (Auto Sync) records configuration changes for an audit trail; apps and device DDs downloadable from the AMS Trex Online Portal |
| Ordering-code positions not listed | The official digit-by-digit ordering guide and certificate numbers for the HPK and LWS3S segments of TREXLHPKLWS3S are not listed in the available materials and are subject to the nameplate / purchase order or the official manual |
| Documentation note | Parameters follow the classic first-generation TREX specifications verified online for No. 1357 and were rechecked against the Emerson official L-module SKU page (e.g. TREXLFPKLWS3S) in this batch; position codes of other configurations are not assumed |
These data were obtained via online search. Sources: the Emerson official AMS Trex Device Communicator product pages (emerson.com and emerson.com/en-us/automation-systems/asset-performance-management/field-device-management/ams-trex-device-communicator) and the official SKU page "TREXLFPKLWS3S, Communication Plus Module, HART + Foundation Fieldbus, IS, Wireless, Standard Support (3 Years), Case" (emerson.com/en-us/catalog/ams-sku-trexlfpklws3s, listing the classic first-generation specifications of the L module: 800 MHz, 2 GB + 32 GB, 512 MB, 5.7 in, IP54, 1 m drop), plus the Emerson official news release "Emerson's Upgraded Handheld Device Communicator..." (2025-10-28, describing the redesigned TREX 2 with a quad-core processor, 8x memory, NIST-traceable calibration and added Bluetooth HART). The differences between the classic generation and the next-generation TREX 2 have been distinguished honestly. The knowledge base returned only purchasing records (TREXLHPKLWS3S communicator), the "Baoman Supply Capability Summary" and similar documents and contains no dedicated technical document for the AMS TREX, so online verification was performed. The digit-by-digit coding of TREXLHPKLWS3S is subject to the official ordering guide, nameplate or purchase order; items not listed in the available materials are not assumed.
IV. Related Models
| Item | Specification |
|---|---|
| Next-generation TREX 2 (TREX2LHPKLWS3S / TREX2CHPNAWS1) | The next-generation platform: 1.2 GHz quad-core Cortex-A53 / new OS / 8x memory / NIST-traceable calibration / Bluetooth HART. Ordering codes such as TREX2LHPKLWS3S also appear in knowledge-base purchasing records; a different generation from the classic TREXLHPKLWS3S in this arrival, and specifications must not be interchanged |
| TREX C-module variant (No. 1357 TREXCHPNAWS1) | The model of the third batch (No. 1357), with the C module = HART + FF (without the L module's mA measurement and loop powering); the L module in this arrival adds a built-in ammeter and Power the Loop |
| Device Communication (Plus) module | The two hot-swappable tiers of HART/FF communication modules for the Trex; the Plus (L) version adds a built-in ammeter to measure 4-20 mA and power the loop, supporting loop and valve diagnostics |
| AMS Device Manager / ValveLink Mobile | The asset-management and valve-diagnostics software paired with the Trex; supports automatic synchronisation of field configuration changes (Auto Sync) and an audit trail |
| 375 / 475 HART communicators | Previous-generation HART communication devices, a different product class from the AMS TREX; this arrival is the classic-generation TREX in the L configuration |
V. Selection Guide & Common Models
Selection guide:Selection starts with confirming the generation: this arrival is the classic first-generation TREXLHPKLWS3S (800 MHz, Windows Embedded Compact 2013, Bluetooth 2.1, 2 GB + 32 GB) and must not be confused with the next-generation TREX 2 (quad-core, 8x memory, NIST calibration). Next confirm the module configuration: this unit uses L / Device Communication Plus (built-in ammeter, 4-20 mA measurement and loop powering), different from the C module (HART + FF) of No. 1357; choose according to whether mA measurement and Power the Loop are needed on site. Verify the communication protocols (HART/FF/Bluetooth), the -20 to +55 degC operating range and IP54 rating, and confirm the licensing status of the required diagnostic apps (Loop Diagnostics, ValveLink Mobile, FF segment diagnostics). Segments such as HPK and LWS3S not decoded digit by digit are subject to the nameplate / purchase order or the official manual. Please feel free to inquire for an item-by-item check against your field protocols and device list.
Common models:This arrival: the Emerson AMS TREX field communicator TREXLHPKLWS3S (classic first generation, L = Device Communication Plus module). Parameters were obtained online from official sources, including data verified for No. 1357, and are for selection and spare-part verification only, not guaranteed values. The specific configuration, position decoding and approval codes are subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China