Emerson AMS Trex Device Communicator TREXCHPNAWS1 - Arrival & Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received the Emerson AMS TREX field communicator, ordering code TREXCHPNAWS1, from the classic first-generation TREX platform (C = HART + FOUNDATION Fieldbus communication module, H = HART application, WS = wireless). The knowledge base contains only purchasing and supply-capability records and no dedicated technical document for this model; the specifications below were obtained online from the Emerson official website and product specification pages, for selection and spare-part verification.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | Emerson (AMS asset-management software product line) |
| Category | AMS TREX device communicator (field communicator), a handheld field instrument with loop-check and diagnostic functions |
| Model | TREXCHPNAWS1 (classic first-generation TREX; distinct from the next-generation TREX 2 / TREX2C…) |
| Ordering-code clues | TREX = TREX platform; C = communication module (HART + FOUNDATION Fieldbus); H = HART application; WS = wireless; the remaining segments (NA, WS1, etc.) are not listed in the available materials and are subject to the nameplate / purchase order or the official manual |
| Core capabilities | Field diagnosis, configuration and calibration of HART / FF / Bluetooth devices; Loop Diagnostics, ValveLink Mobile valve diagnostics and Fieldbus segment diagnostics |
| Typical applications | Instrument commissioning, troubleshooting and valve maintenance in harsh industries such as power, oil and petrochemical |
| Source status | No dedicated technical document exists in the knowledge base; parameters were obtained online from official sources |
III. Technical Data
The specifications below apply to the classic first-generation AMS TREX (TREXCHPNAWS1), which uses an 800 MHz ARM Cortex A8 / NXP microprocessor, Windows Embedded Compact 2013, 2 GB + 32 GB flash and 512 MB RAM. It is a different platform from the next-generation TREX 2 launched in 2026 (1.2 GHz quad-core Cortex-A53, Android 14, 64 GB + 4 GB RAM, Bluetooth Low Energy) and the specifications must not be interchanged. In the model code, C denotes the HART + FF communication module. Items not listed item by item in the official materials are marked as not listed in the available materials and are subject to the nameplate / purchase order or the official manual; no values are assumed.
| Item | Specification |
|---|---|
| Brand / model | Emerson; AMS TREX TREXCHPNAWS1 (classic first generation, module C = HART + FF) |
| Microprocessor | 800 MHz ARM Cortex A8 / NXP microprocessor |
| Memory and storage | Internal flash 2 GB NAND + 32 GB extended flash; RAM 512 MB DDR3 SDRAM |
| Display | 5.7 in (14.5 cm) colour VGA resistive touchscreen, 640 × 480 pixels; adjustable brightness and glove-operable |
| Operating system | Windows Embedded Compact 2013 (the next-generation TREX 2 uses a custom Android 14 platform) |
| Communication protocols | HART, FOUNDATION Fieldbus (FF); multi-vendor field devices via EDDL; Bluetooth 2.1, Wi-Fi and active NFC |
| Communication module C | Device Communication Module: HART and FF terminals (two banana jack plugs), supporting field-device communication and segment diagnostics |
| Weight | Approximately 2.9 lbs (1330 g) |
| Battery and charging | Rechargeable lithium-ion power module; 8+ hours of typical use; charge time 3–4 hours |
| Operating temperature | -20 to +55 °C (-4 to +131 °F); for IS approval -20 to +50 °C (-4 to +122 °F) |
| Storage temperature | With power module -20 to +50 °C (less than 1 month); without power module -20 to +60 °C |
| Enclosure and shock | IP54; survives a 1 m all-sides-and-corners drop test onto concrete; meets global Intrinsic Safety (IS) standards |
| Functional applications | Loop Diagnostics, ValveLink Mobile valve diagnostics, Fieldbus segment diagnostics, Power the Loop (single-cable device powering) and automatic synchronisation with AMS Device Manager (Auto Sync) |
| Documentation note | The official ordering guide and certificate numbers for the individual segments of TREXCHPNAWS1 are not listed in the available materials and are subject to the nameplate / purchase order or the official manual |
These data were obtained via online search. Sources: the Emerson official AMS Trex Device Communicator product pages (emerson.com/trex and emerson.com/en-us/automation/asset-performance-management/field-device-management/ams-trex-device-communicator) and the official data sheet "AMS Trex Device Communicator" (first-generation TREX specifications and TREXCHPNAWS1 ordering information as published on fieldcommunicator.net and new-plc.com). The knowledge base returned only the "Baoman Supply Capability Summary", purchasing records and similar documents and contains no dedicated technical document for the AMS TREX, so online verification was performed. The differences between the classic generation and the next-generation TREX 2 have been distinguished honestly. The digit-by-digit coding of TREXCHPNAWS1 is subject to the official ordering guide, nameplate or purchase order; items not listed in the available materials are not assumed.
IV. Related Models
| Item | Specification |
|---|---|
| Next-generation TREX 2 (TREX2C…) | The 2026 next-generation platform: 1.2 GHz quad-core Cortex-A53 / custom Android 14 / 64 GB NAND + 4 GB RAM / Bluetooth Low Energy; a different generation from the classic TREXCHPNAWS1 in this arrival, and specifications must not be interchanged |
| TREX L-module variants | Other ordering codes such as TREXLHPKLWS3S and TREX2LHPKLWS3S appear in the knowledge-base purchasing records; L = Device Communication Plus module (with mA measurement and loop powering); specific configuration is subject to the nameplate / purchase order |
| 375 / 475 HART communicators | Previous-generation HART communication devices mentioned in the knowledge-base document "Azbil AVP Positioner Selection"; a different product class from the AMS TREX, which is what this arrival contains |
| AMS Device Manager / ValveLink Mobile | The asset-management and valve-diagnostics software paired with the Trex; supports automatic synchronisation of field configuration data (Auto Sync) |
V. Selection Guide & Common Models
Selection guide:Selection starts with confirming the generation: this arrival is the classic first-generation TREXCHPNAWS1 (800 MHz, Windows Embedded Compact 2013, Bluetooth 2.1) and must not be confused with the next-generation TREX 2. Next, verify the communication module from the ordering code (C = HART + FF in this unit); if mA measurement and loop powering (Power the Loop) are required, confirm whether an L / Device Communication Plus module is needed — this model does not carry the L code, and segments not listed item by item in the available materials are subject to the nameplate / purchase order or the official manual. Check the application against -20 to +55 °C (-20 to +50 °C in intrinsic-safe areas) and the IP54 rating, and confirm that the required diagnostic apps (Loop Diagnostics, ValveLink Mobile, FF segment diagnostics) are licensed. Please feel free to inquire for an item-by-item check against your field protocols and device list.
Common models:This arrival: the Emerson AMS TREX field communicator TREXCHPNAWS1 (classic first generation, HART + FF communication module C). Parameters were obtained online from official sources and are for selection and spare-part verification only, not guaranteed values. The specific configuration is subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH
